4
GB
GB
Application
The GROHE Blue
®
Chilled & Sparkling
fitting with integrated
cooler/carbonator is designed for use in the private,
non-commercial sector.
The filter head is fitted with a type-tested non-return valve.
The water filtrate is classified as Category 2 according
to EN 1717.
The cooler/carbonator works with environmentally-friendly
refrigerant.
Safety notes
This device
is not
intended for use by persons
(including children) with physical, sensory or mental
impairments or a lack of experience or knowledge
in using devices of this type.
Children must be supervised
to ensure that they
do not play with the device.
Prevent danger resulting from damaged power
supply cables. In the case of damage, the mains
cable
must
be replaced by the manufacturer or his
customer service department, or an equally qualified
person.
The mains plug provided (type EF plug) is
only
suitable for use with Schuko (CEE 7/4) sockets.
CO
2
(carbon dioxide) is a gas and
must not
be
inhaled due to danger of suffocation.
Only
CO
2
cylinders up to max. 2 kg
may be used
. When
using these, the room size
must
be at least 13 m
2
.
The CO
2
cylinder is pressurised. It
must
only
be
operated in the vertical position and
must
be
secured against falling over.
Operation is
only
permissible in conjunction with
the accompanying adapter with pressure gauge.
• For hygiene reasons, the filter system
must
be flushed
before using for the first time.
• The filter system
must always
be operated with cold water
of foodstuff grade.
• The filter head
must
be replaced after 5 years.
• The system
must not
be transported with the CO
2
cylinder
connected.
• The CO
2
cylinder
must not
be maintained or repaired by
unauthorised persons.
• During cleaning, do
not
spray the cooler/carbonator or the
plug directly or indirectly with water.
• The cooler/carbonator
must
be connected to a permanent
power supply.
• At the installation location, the cooler/carbonator, CO
2
cylinder and filter system
must
be protected from
mechanical damage, heat and direct sunlight.
Do
not
install near heat sources or an open fire.
• The cooler/carbonator
must
be placed in an upright position.
• The cooler/carbonator
must not
be opened.
• Installation of the fitting and cooler/carbonator with filter
cartridge
is only permitted
in frost-free rooms.
• The cooler/carbonator is
only
suitable for indoor use.
• Use
only genuine replacement parts and accessories
.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Technical data
Cooler/carbonator electrical data:
• Connection:
Wall socket with earth wire, protected
via a 10 A fuse
• Voltage supply:
230 V AC / 50 Hz
• Max. power consumption:
270 W
• Type of protection:
IP21
• Relative air humidity:
max. 75%
• Refrigerant:
0.065 kg - R134a
• Safety shut-off of pump:
approx. 4:30 min
Sanitary data:
• Cooler/carbonator cooled water capacity:
1.4 l
• System operating pressure:
0.2 – 0.6 MPa
• Flow rate at 0.3 MPa flow pressure:
approx. 2 l/min
• Ambient temperature:
4 – 32 °C
• Temperature
– Cooler/carbonator water inlet:
max. 20 °C
– Cooled water temperature:
approx. 5 – 10 °C
• Sound pressure level L
p
A:
50 ± 4 dB
• Adjustable bypass, factory setting:
40%
• Filter capacity at 40% bypass
(Carbonate hardness 14 - 17 °KH):
max. 600 litres
corresponds to max. 12 months
Electrical test data
• Software class:
A
• Contamination class:
2
• Rated surge voltage:
2,500 V
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
Electrical installation work must only be performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 364-7-701-1984 (corresponding
to VDE 0100 Part 701) as well as all national and
local regulations.
Installation
Refer to the installation dimensions on fold-out page I and II,
Fig. [1].
Flush pipes thoroughly before and after installation
(observe EN 806)
.
Install
pressure-reducing valve on service valve
,
see fold-
out page II, Fig. [2].
Install and connect
fitting
,
see Figs. [3] and [4].
This product conforms to the requirements of the
relevant EU guidelines.
Summary of Contents for Blue Minta Mono Chilled & Sparkling 31 302
Page 37: ...34 UAE ...
Page 38: ...35 ...
Page 39: ...36 46 724 46 724 1 2 ...
Page 89: ......
Page 90: ...III 15 2 1 20 16 IN 14 2 L 19 1 2 3 18 17 21 25 4mm 24 10 C 5 C 22 23 ...