Application

Can be used in conjunction with:

• Pressurised storage heaters

• Thermally controlled instantaneous heaters

• Hydraulically controlled instantaneous heaters

Operation with unpressurised storage heaters (= open water 
heaters) is not possible.

Technical data

• Flow pressure

- min.

0.5 bar

- recommended by 29 041, 29 042

1 - 5 bar

- recommended by 29 062

1 - 5 bar

diverter automatically

 

0.7 - 5 bar

diverter seccured manually

 

< 0.7 bar

• Operating pressure max.

10 bar

• Test pressure

16 bar

A pressure reducing valve must be fitted in the supply line if 
static pressures exceed 5 bar to satisfy noise level ratings.

Avoid major pressure differences between hot and cold water 
supply.

• Temperature

Hot water inlet:

max. 80 °C

Recommended (energy saving):

60 °C

• Water connection

hot - left

cold - right

Note:

This fitting can be combined with head and hand shower sets 
by using a 3-way diverter.

Important note:

Never install shut-off valves in the outlet pipe (mixed 
water) downstream of any built-in mixer.

Installation

Prepare the wall for the installation.

• Prepare the holes for the single lever mixer and slots for the 

pipes.

Align single lever mixer using fitting template and fit,

 

see fold-out page I, Figs. [1] and [2].

• Permissible tolerances are given on the dimensional 

drawing.

• The arrow on the fitting template must point upwards.

• To align place a spirit level on the fitting template, see 

Fig. [1].

• The housing is provided with pre-drilled holes (B) to facilitate 

mounting the fitting to the wall.

• The finished surface of the wall (C) must lie within the 

area (X) of the fitting template, see Fig. [2].

• The cold water supply must be connected on the right, hot 

water supply on the left.

Connect pipes.

Open cold and hot-water supply and check connections 
for water-tightness.

Flush piping system prior and after installation of fitting 
thoroughly (Consider EN 806)! 

Plaster and tile the wall, see Fig. [3].

Attention! You must tile directly to the fitting template!

Do 

not

 remove the fitting template before final installation.

Final installation

Remove fitting template, 

see Fig. [4].

Install escutcheon and lever, 

see Figs. [5].

Seal the escutcheon with silicone.

Check mixer for correct operation,

 see Fig. [6].

Function of automatic diverter (D) for 29 041,

 see Fig. [6].

Pulling the lever will release water delivery.

On the bath mixer, water will always emerge from the lower 
outlet first (e.g. bath outlet).

Pressing diverter (D) shuts off the flow of water to the bath and 
delivers water to the shower outlet.

When the mixer is closed, the diverter is released 
automatically so that when the mixer is opened again, water 
will always emerge from the lower outlet first (e.g. bath outlet).

Function of manual diverter (E) for 29 062,

 see Fig. [7].

Pulling the lever will release water delivery.

On the bath mixer, water will always emerge from the lower 
outlet first (e.g. bath outlet).

Pressing diverter (E) shuts off the flow of water to the bath and 
delivers water to the shower outlet.

In addition, the diverter assembly can be secured manually 
(advantageous at pressures below 0.7 bar or at low rates of 
discharge). In this case, press the diverter knob of the diverter 
assembly (E) and turn it clockwise.

The diverter leave in this oposition until turning anti-clockwise.

Care

Dear Customer,

We want to ensure that you get long-lasting satisfaction and 
pleasure from your 

GROHE

 fitting. Therefore, please read the 

following care instructions because damage to the surface and 
underlying material resulting from improper treatment is not 
covered by warranty.

Do not use any abrasive sponges or scouring agents for 
cleaning. We also advise you not to use cleaning agents 
containing solvent or acid, limescale removers, household 
vinegar and cleaning agents with acetic acid in them. They are 
aggressive to the surface - and will leave your fitting dull and 
scratched. As the formulations of commercially available 
cleaning agents frequently change, we cannot guarantee they 
will provide the gentle care our fitting deserves.

Clean the fitting with a little soap and a moist cloth only, then 
simply rinse off and wipe dry. You can avoid lime spots by 
drying the fitting each time it is used. If lime deposits do occur, 
remove them with 

GrohClean

, our environment-friendly 

cleaning liquid. 

GrohClean

 is specially formulated to clean the 

surface of our fittings gently. 

GrohClean

 is available from your 

supplier.