background image

1

English

Application 

Operation is possible in conjunction with:
- Pressurized storage heaters
Operation with low-pressure storage heaters (displacement 
water heaters) is 

not

 possible.

Specifications 

• Max. flow
- Spout

approx. 29 L/min or 7.7 gpm

- Handspray

max. 9.5 L/min or 2.5 gpm

• Flow pressure 
- min. 7.25 

psi

- recommended 

14.5 - 72.5 psi

- greater than 72.5 psi, fit pressure reducing valves
• Max. operating pressure

145 psi

• Test pressure 

232 psi

• Temperature
- max. (hot water inlet)

176 

°

F

• Water connection

cold on right side

hot on left side

Notes

- Installation of backflow protection must comply with local 

codes and regulations.

- An access panel must be provided for access to diverter and 

hose connections.

- Major pressure differences between hot and cold water 

supply should be avoided.

Installation

Layout dimensions to establish centers and proper clearences, 
see dimensional drawings on fold-out page I.
The dimensional drawing and the drilling template for fitting 
plate (A) (not included in the scope of deliver) show a form of 
installation suggested by 

GROHE

, for which no further 

components are required, see fold-out page I.

For deviation to the suggested installation, observe minimum 
clearance required for escutcheon sizes.
Prepare 

fitting plate

 (A).

Install 

thermostat unit,

 see Figs. [1], [2] and [3].

1. Fasten mounting plate (B) to fitting plate (A) centrally, from 

below using screws (C), see Fig. [1].

2. Attach pre-mounted thermostat unit (D) to the fitting plate 

from above using bolts (E), see Fig. [2].

3. Secure 2 diagonally-opposed screws (E) from below using 

cap nuts (F).
By loosening the screws (E), the thermostat unit can be 
moved to the right and to the left, in order to enable opening 
and closing of the isolating valves following installation or for 
maintenance purposes.

4. Connect hoses (G) with G1/2 to the thermostat unit.
5. Attach sleeve (H), see Fig. [3].
6. Grease seal (J1) of escutcheon mounting base (J2) with the 

special grease supplied.

7. Attach the escutcheon mounting base (J2) to the fitting and 

fasten with mounting set (J3).

8. Attach escutcheon (J).
9. Install thermostat handle (K), snap insert (L) and screw (M).

The thermostat is adjusted at the factory. If, due to 
installation conditions, re-adjustment is necessary, please 
see 

Adjustment

.

Install side valve,

 see Figs. [3] and [4].

1. Install mounting and sealing set (N1) on the side valve 

shank. 

2. Fasten the side valve from above using mounting and 

sealing set (N2).
The distance from the side valve upper edge to fitting 
plate (A) must be 5/16" - 7/16", see Fig. [4].

3. Attach escutcheon (O).
4. Attach spindle & sleeve (P).
5. Connect hose (G) to the side valve with G3/4 and to the 

thermostat unit with G1/2.

Install

 

diverter, 

see Fig. [4] and fold-out page II, Fig. [5].

1. Install mounting and sealing set (T1) on the diverter shank, 

see Fig. [5]. 

2. Fasten the diverter housing from above using mounting and 

sealing set (T2).
The distance from the diverter housing upper edge to fitting 
plate (A) must be 5/16" - 7/16" , see Fig. [4].

3. Attach spindle (U), see Fig. [5]. 

The distance from spindle (U) upper edge to fitting plate (A) 
must be 2" . Fasten adjusted spindle (U) using set 
screw (U1).

4. Attach escutcheon (V).
5. Install escutcheon hold down (W).
6. Install diverter knob (X).
7. Attach hose (Y) to the side valve and to the diverter.
8. Attach hoses (Y1) and (Y2).

Install

 

handspray, 

see Fig. [6].

1. Attach hose guide (Z) to fitting plate (A) using mounting and 

sealing set (Z1).

2. Install spray hose (B1) with hose (Y1). 

Avoid crossing the hoses.

3. Insert spray hose (B1) through hose guide (Z).
4. Attach tapered nut (D1) to spray hose (B1).
5. Insert seal (E1) in the handshower adaptor (D1). Attach 

handspray (F1) to the handshower adaptor.

When using the handspray (F1), it must be ensured that spray 
water does not penetrate the hose guide (Z).

Install

 

spout, 

see Fig. [7].

1. Install shank with sealing set (G1).
2. Attach hose (Y2) between spout and diverter.
3. Attach spout (J1) to the shank and insert set screw (K1) 

using a 4mm allen wrench.

Flush pipes thoroughly.

Attach hoses (G) to the existing connections, see Fig. [8].

Cold water connection on right, hot water connection on 
left.

Observe marking on the housing.

Check all connections for leaks

Summary of Contents for Atrio 21 059

Page 1: ...página 3 English Français Español page 1 page 2 94 393 131 ÄM 200351 12 04 Linie Europlus Atrio 21 059 página 5 English Français Español page 1 page 3 ...

Page 2: ... l utilisateur de la robinetterie Entregue estas instrucciones al usuario final de la grifería Please pass these instructions on to the end user of the fitting 1 A B C C 2 E F G G D 24mm 3 M L K J J3 J1 J2 H G P O N2 A N1 G 30mm 29mm 24mm 4 ...

Page 3: ...4mm 29mm 29mm 50mm 7mm 19mm 10 H P2 P1 M1 M2 Q1 R1 O1 S1 22mm 2 5mm 10mm 8mm 11 K1 17mm 4mm P O T3 U2 N4 12 F1 E1 D1 B1 13mm B2 7 J1 K1 29mm Y2 G1 G1 32mm 30mm 4mm 8 A G K1 K2 K1 K2 4mm 4mm 29mm 29mm 21 072 21 073 6 F1 E1 D1 Z 8mm A Z1 B1 Y1 32mm 19mm 13 7mm 19mm 17mm V1 V2 V3 W V V4 ...

Page 4: ...the escutcheon mounting base J2 to the fitting and fasten with mounting set J3 8 Attach escutcheon J 9 Install thermostat handle K snap insert L and screw M The thermostat is adjusted at the factory If due to installation conditions re adjustment is necessary please see Adjustment Install side valve see Figs 3 and 4 1 Install mounting and sealing set N1 on the side valve shank 2 Fasten the side va...

Page 5: ...s O1 using an 8mm allen wrench see fold out page II Fig 10 I Thermostatic cartridge non return valve and isolating valves see Fig 10 Caution Shut off main pipes 1 Same procedure as for closing isolating valves steps 1 5 2 Detach sleeve H 3 Remove clip P1 4 Detach stop ring P2 5 Detach regulating nut M1 with overload unit M2 6 Loosen extension set Q1 using a 2 5mm allen wrench and remove 7 Remove t...

Page 6: ... le porte rosace J2 sur la robinetterie et le fixer avec le kit de fixation J3 8 Insérer la rosace J 9 Monter la poignée graduée K l isolateur L et la vis M Le thermostat a été réglé en usine Si au moment de l installation un réglage devait s avérer nécessaire voir Réglage Montage du robinet d arrêt voir fig 3 et 4 1 Monter le kit de joint fixation N1 sur l embase du robinet d arrêt 2 Serrer le ro...

Page 7: ...mer les robinets d arrêt voir fig 2 7 Visser les deux robinets d arrêt O1 avec une clé Allen de 8mm voir volet II fig 10 I Elément thermostatique clapet anti retour et robinets d arrêt voir fig 10 1 Même procédure que pour la fermeture des robinets d arrêt points 1 à 5 2 Retirer la douille H 3 Enlever l agrafe P1 4 Enlever la bague de butée P2 5 Retirer l écrou de réglage M1 avec l unité de surcha...

Page 8: ... juego de fijación J3 8 Encajar el rosetón J 9 Montar la empuñadura graduada K el aislante L y el tornillo M El termostato viene ajustado de fábrica Si por razones de necesidades de la instalación fuera necesario realizar un ajuste posterior véase Ajuste Montar la válvula lateral véanse figs 3 y 4 1 Montar el juego de fijación y estanqueidad N1 sobre el vástago de la válvula lateral 2 Enroscar la ...

Page 9: ... 7 Cerrar ambos bloqueos de seguridad O1 con una llave Allen de 8mm véase la página desplegable II fig 10 I Termoelemento válvula antirretorno y bloqueos de seguridad véase fig 10 1 Misma forma de proceder como para cerrar los bloqueos de seguridad Punto 1 5 2 Quitar el casquillo H 3 Extraer la horquilla P1 4 Extraer el anillo de tope P2 5 Extraer la tuerca de regulación M1 con unidad de sobrecarg...

Page 10: ...III ...

Page 11: ...IV ...

Page 12: ......