Safety notes
• Before and during use make sure that the thermostat is
functioning correctly. Children and adults with reduced
sensory capabilities should not use the product
unsupervised.
• When the domestic water system is drained, the thermostats
must be drained separately since non-return valves are
installed in the hot and cold water connections. For this
purpose, the mixer must be removed from the wall.
• Installation is only possible in frost-free rooms.
• The plug-in connectors must
not
be directly or indirectly
sprayed with water when cleaning.
• Use
only genuine replacement parts and accessories
.
The use of other parts will result in voiding of the warranty
and the CE identification, and could lead to injuries.
Application
Infrared fittings with thermostat are designed for hot water
supply via pressurised storage heaters and, utilised in this
way, provide the best temperature accuracy. With sufficient
power output (from 18 kW or 250 kcal/min), electric or gas
instantaneous heaters are also suitable.
All thermostats are adjusted in the factory at a flow pressure
of 0.3 MPa on both sides.
Should temperature deviations occur on account of special
installation conditions, the thermostat must be adapted to local
conditions (see “Adjusting”).
Technical data
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off:
60 s
• Run-on time:
1 s
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape
- Start / stop water flow:
5cm
- Automatically stop water flow:
40cm
• Type of fitting protection:
IP 59K
Hot water temperature at supply connection min. 2 °C
higher than mixed water temperature.
Thermal disinfection possible.
Electrical test data
• Software class
A
• Contamination class
2
• Rated surge voltage
2500 V
• Temperature of ball impact test
100 °C
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Installation
, see page 2.
Flush pipes thoroughly before and after
installation
(observe EN 806)
!
Open hot and cold water supply and check that
connections are watertight.
Reversed connection
(hot on right - cold on left)
Replace thermostatic compact cartridge, see Replacement
Parts, page 1,Prod. no. 47 175 (1/2”).
When using this thermostatic cartridge, the Cool Touch
function is no longer available.
Adjusting
Temperature adjustment,
see page 3 - 4 Figs. [1]
to [3].
Störung
Ursache
Abhilfe
Wasser fließt nicht
• Sieb vor Magnetventil verstopft
• Magnetventil defekt
• Steckverbinder ohne Kontakt
• Keine Spannung
- Batterie leer
(Kontrollleuchte signalisiert Dauerleuchten)
- Sieb reinigen
- Magnetventil austauschen
- Steckverbinder prüfen
- Batterie austauschen
Wasser fließt
ungewollt
• Erfassungsbereich der Sensorik für örtliche
Gegebenheiten zu groß eingestellt
• Automatische Spülung aktiv
• Magnetventil defekt
- Reichweite mit Fernbedienung (Sonderzubehör,
Bestell-Nr.: 36 407) / App reduzieren
- 1 - 10 Minuten warten
- Magnetventil austauschen
Wassermenge zu
gering
• Mousseur verschmutzt
• Sieb vor Magnetventil verschmutzt
• Siebe in der Anschlussverschraubung
verschmutzt
- Mousseur reinigen oder austauschen
- Sieb reinigen
- Siebe reinigen oder austauschen
Wassertemperatur
zu hoch oder
niedrig
• Thermostat nicht auf örtlichen Druck justiert
• Rückflussverhinderer defekt
- Thermoelement justieren
- Rückflussverhinderer austauschen
6
Summary of Contents for 36 457
Page 2: ...I 1...
Page 3: ...1 2 30mm 34mm 19 377 19 332 19 001 22mm 34 42 150 1 2 19 377 30mm 1 3 2 4...
Page 4: ...3 1 2...
Page 5: ...4 3 1 2...
Page 21: ...16 20...
Page 43: ...38 4 1 2 35 C 43 C 10 3 43 o 1 36 407 1 10 42...
Page 44: ...1 43 12mm 30mm 12mm 19 377 19 332 13mm 3mm 2 5mm 1 2 3 3 3 3 1 2...