background image

19

Guarantee

Guarantee declaration
Our products correspond to the valid tech-
nical and water supply standards as well as 
the relevant approvals requirements. We 
guarantee them to be free of design and 
production faults at the time of delivery and 
that with correct use and care in accordance 
with our printed instructions they will function 
reliably.

Guarantee period 
- The guarantee is valid in private homes for 

5 years from the purchase date. Proof of 
purchase has to be provided when making 
a guarantee claim.

-  By use in commercial or institutional appli-

cations the guarantee is valid for 1 year 
after first use. An extension of the 
guarantee up to 5 years can be achieved 
by showing that the product is 
professionally maintained each year.

To make a guarantee claim, proof of pur-
chase or, the beginning of use is required. 
The guarantee period is not renewed or in-
creased through supply of spare parts or 
repair during the guarantee period. The 
guarantee period for purchased spare parts 
is the same as for original products. 

Guarantee performance
A)During the whole guarantee period we will 

correct all functional defects for which we 
are responsible (limitations see E + F).

B)It is our option if we correct the defects by 

repair or replacement.

C)During the above guarantee period we will 

not charge for the cost of parts, travel, 
working time, freight and packaging 
needed to effect the correction of defects.

D)If we are not able to correct the defect we 

are prepared to supply a replacement 
product.

E)Deliberate or careless damage is not co-

vered by this guarantee. If the installation, 
assembly or care instructions that were 
valid at the time of installation are not fol-
lowed or the product is used for a purpose 
other than that given in the written infor-
mation the guarantee declaration does not 
apply. Problems caused by dirt, lime-scale 
or aggressive cleaners are not covered by 
the guarantee.

F)The guarantee becomes void if repairs are 

not carried out competently or spare parts 
of non GROHE origin are used.

G)Replaced parts become the property of 

GROHE and are to be surrendered to our 
service personnel or sent to our registered 
offices.

Please enter date of purchase and installation here.

Our address

GROHE Limited
1, River Road 
Barking, 
Essex, IG11 OHD
GB
Tel.: 01 81 / 5 94 72 92
Fax: 01 81 / 5 94 88 98

 © 1999 Friedrich Grohe AG

                       Friedrich Grohe Aktiengesellschaft · Hauptstraße 137 · 58675 Hemer
                              Tel. 0 23 72 / 93-0 · Telex 827433 · Fax: 0 23 72 / 93 13 22

950632.book : garant_uk.fm  Seite 19  Mittwoch, Oktober 4, 2000  7:42 AM

Summary of Contents for 35 235

Page 1: ...ng Guide Please leave this document with the user after finishing installation 95 063 231 ÄM 49 016 10 00 Grohsafe Concealed Pressure Balance Valve with Shower Kit 35 235 35 236 950632 book t95063 fm Seite 1 Mittwoch Oktober 4 2000 7 42 AM ...

Page 2: ...Shower Arm Headshower Handshower Filter Elbow Outlet Stop Shower Rail Flexible Hose 35 235 35 236 35 235 35 236 Filter Fitting Template Backplate Bracket Screws Wallplugs Clips Screws Screws 35 235 Table Of Contents Installation Dimensions mm 1 2 35 236 kl950632 fm Seite 1 Montag Oktober 2 2000 8 25 AM ...

Page 3: ...ts 3 4 35 235 1 2 4 3 7 8 13 7 1 8 1 8 2 5 2 1 1 1 15 6 35 236 1 2 4 5 9 10 11 12 13 14 11 10 1 15 10 2 1 3 12 1 12 2 2 1 1 1 10 2 8 1 9 1 6 Spare Parts Spare Parts kl950632 fm Seite 2 Montag Oktober 2 2000 8 25 AM ...

Page 4: ...wer spray plate 45 794 1 10 Shower rail 28 666 1 10 1 Sliding shower holder 07 659 1 10 2 Shower rail holder 45 362 1 10 2 1 Cover cap 45 363 1 11 Flexible hose 28 151 1 12 Elbow outlet 28 680 1 12 1 Non return valve 45 481 1 12 2 Cover cap 45 364 1 Optional accessories 13 Extension 25mm 47 069 1 14 Compensation ring 45 406 1 15 Service stops 47 038 2 No Description Cat No Pack ing unit 1 Handle c...

Page 5: ... to prevent the ingress of water borne debris New Water Regulations This GROHE product is designed to comply with the current Water Bylaw 17 and the new Water Regulations covering back flow pre vention It must be installed in accordance with local authority bye laws Incorrect instal lation could contravene bye law installation requirements Specification Concealed single handle pressure balancing s...

Page 6: ...d partition wall structure or the rear face of a shower cubicle or laminated panel Solid and dry lined walls Determine the route for the incoming hot and cold water supply and for the outlet pipe work in accordance with the pressure balance valve pressure balancing valve 1 Mark a 160mm diameter hole for the valve and mark the fixing hole positions for the bracket A see Fig 1 2 Drill 6mm diameter h...

Page 7: ...e D onto the mixer body E Make sure that the locating pins on the valve body slot into the apertures on the back plate see Fig 6 3 Screw backplate D to bracket A with fixing screws D1 4 Fix the valve body E to the backplate D with clips F and screws F1 Do not use excessive force to tighten the screws F1 5 Align the valve with the bracket horizon tally vertically and parallel to the wall by using a...

Page 8: ...rk and connections to the pressure balance valve for leaks Reinstall fitting template for finishing wall surface 8 Observe the installation depth in accor dance with the instructions given on the fitting template see Figs 8 for Head shower and 9 for Handshower 9 Fitting template must remain intact for finished wall surface measurements and as a template for plastering and or tiling On tiled wall s...

Page 9: ...s fitted against a particularly rough surface deep tile joints highly textured tile 6 Tighten the wall plate screws 7 Push adjustable hot water limit stop K to the intermediate ring M as described in Fig 13 Please refer to chapter Maximum Hot Water Limit Setting on page 13 for limiting maximum outlet temperature 8 Push the handle L on the intermediate handle M so that the OFF position on the wall ...

Page 10: ...idge O out of the valve body Do not damage the O ring seals see Fig 16 8 Reverse the pressure balancing cartridge 180 by turning it upside down Place it into the valve body Ensure the two alignment pins O1 on the rear of the pressure balancing cartridge are properly seated in the holes Z of the valve body Reassemble in reverse order Be sure that the stop ring N is in the previously noted position ...

Page 11: ...ing cartridge O out of the valve body Do not damage the O ring seals see Fig 19 7 Reverse the pressure balancing cartridge 180 by turning it upside down Place it into the valve body Ensure the two alignment pins O1 on the rear of the pressure balancing cartridge are properly seated in the holes Z of the valve body Notice the position of hot H and cold C markings on the cartridge to assure the corr...

Page 12: ... limit stop K 3 Turn the intermediate ring M counter clockwise until the outlet water reaches the desired temperature see Fig 21 4 Place the hot water limit stop K over the splines on the intermediate handle with the limit stop resting against the wall plate stop post see Fig 22 5 Close the valve by turning the intermediate handle M clockwise 6 Reinstall handle as described in Fig 20 in reversed d...

Page 13: ...ut of the valve body noting the location of H and C marking near the cartridge inlets The pressure balancing cartridge O must be replaced as a complete unit Reassemble in reverse order Ensure the two alignment pins O1 on the rear of the pressure balancing cartridge are properly seated in the holes Z of the valve body and that the hot H and cold C markings are on the correct side Be sure that the s...

Page 14: ...surface of our fittings Problem Cause Remedy Shower control opening through hot Hot and cold water supplies have been connected in reverse Rotate cartridge as described in chapter Reversed Supplies Installation Shower head drips after shutting off the valve O ring seal on the inlet of the cartridge is faulty Incorrect setting of the stop ring against the stop pin causing a partially opened cartrid...

Page 15: ...imitations see E F B It is our option if we correct the defects by repair or replacement C During the above guarantee period we will not charge for the cost of parts travel working time freight and packaging needed to effect the correction of defects D If we are not able to correct the defect we are prepared to supply a replacement product E Deliberate or careless damage is not co vered by this gu...

Reviews: