background image

15

Care

Trouble Shooting

We want to ensure that you get long-lasting 
satisfaction and pleasure from your GROHE 
fitting. Therefore, please read the following 
care instructions because damage to the 
surface and underlying material resulting 
from improper treatment is not covered by 
guarantee.

Do not use any abrasive sponges or scou-
ring agents for cleaning. We also advise not 
to use cleaning agents containing solvent or 
acid, limescale removers, household vinegar 
and cleaning agents with acetic acid. They 
are aggressive to the surface and will leave

your fitting dull and scratched. As the for-
mulations of commercially available cleaning 
agents frequently change, we cannot gua-
rantee they will provide the gentle care our 
fitting deserves.

Clean the fitting with a little soap and a moist 
cloth only, then simply rinse off and wipe dry. 
You can avoid lime spots by drying the fitting 
each time it is used. If lime deposits do oc-
cur, remove them with Grohclean (ref. no. 
18 078), our environment-friendly cleaning 
liquid. Grohclean is specially formulated to  
gently clean the surface of our fittings. 

Problem

Cause

Remedy

Shower control 
opening through hot

Hot and cold water supplies have 
been connected in reverse

Rotate cartridge as described in 
chapter

 "

Reversed Supplies 

Installation

"

Shower head drips 
after shutting off the 
valve

O-ring seal on the inlet of the 
cartridge is faulty

Incorrect setting of the stop ring 
against the stop pin causing a 
partially opened cartridge

Check the O-ring for cuts or 
damage and replace if necessary

Detach stop ring and close cartrid-
ge without using excessive force. 
Replace stop ring so it is position-
ed against stop pin on the cover

Shower insufficiently 
hot

Adjustable hot water limit stop 
incorrectly set

Hot water supply temperature too 
low

Refer to the instructions in chapter 

"

Maximum Hot Water Limit 

Setting

"

Check hot water source tempera-
ture setting

No flow of hot or cold 
water

Either the hot or cold side is not 
fully pressurized

Debris caught inside the inlet of 
the cartridge

Be sure the system is fully 
pressurized

Remove cartridge and flush out or 
remove any debris lodged inside 
the hot or cold inlets

Valve body too deep in 
the wall

The measured rough in or finished 
wall surface is incorrect

Install 25mm extension

950632.book : i95063gb.fm  Seite 15  Mittwoch, Oktober 4, 2000  7:42 AM

Summary of Contents for 35 235

Page 1: ...ng Guide Please leave this document with the user after finishing installation 95 063 231 ÄM 49 016 10 00 Grohsafe Concealed Pressure Balance Valve with Shower Kit 35 235 35 236 950632 book t95063 fm Seite 1 Mittwoch Oktober 4 2000 7 42 AM ...

Page 2: ...Shower Arm Headshower Handshower Filter Elbow Outlet Stop Shower Rail Flexible Hose 35 235 35 236 35 235 35 236 Filter Fitting Template Backplate Bracket Screws Wallplugs Clips Screws Screws 35 235 Table Of Contents Installation Dimensions mm 1 2 35 236 kl950632 fm Seite 1 Montag Oktober 2 2000 8 25 AM ...

Page 3: ...ts 3 4 35 235 1 2 4 3 7 8 13 7 1 8 1 8 2 5 2 1 1 1 15 6 35 236 1 2 4 5 9 10 11 12 13 14 11 10 1 15 10 2 1 3 12 1 12 2 2 1 1 1 10 2 8 1 9 1 6 Spare Parts Spare Parts kl950632 fm Seite 2 Montag Oktober 2 2000 8 25 AM ...

Page 4: ...wer spray plate 45 794 1 10 Shower rail 28 666 1 10 1 Sliding shower holder 07 659 1 10 2 Shower rail holder 45 362 1 10 2 1 Cover cap 45 363 1 11 Flexible hose 28 151 1 12 Elbow outlet 28 680 1 12 1 Non return valve 45 481 1 12 2 Cover cap 45 364 1 Optional accessories 13 Extension 25mm 47 069 1 14 Compensation ring 45 406 1 15 Service stops 47 038 2 No Description Cat No Pack ing unit 1 Handle c...

Page 5: ... to prevent the ingress of water borne debris New Water Regulations This GROHE product is designed to comply with the current Water Bylaw 17 and the new Water Regulations covering back flow pre vention It must be installed in accordance with local authority bye laws Incorrect instal lation could contravene bye law installation requirements Specification Concealed single handle pressure balancing s...

Page 6: ...d partition wall structure or the rear face of a shower cubicle or laminated panel Solid and dry lined walls Determine the route for the incoming hot and cold water supply and for the outlet pipe work in accordance with the pressure balance valve pressure balancing valve 1 Mark a 160mm diameter hole for the valve and mark the fixing hole positions for the bracket A see Fig 1 2 Drill 6mm diameter h...

Page 7: ...e D onto the mixer body E Make sure that the locating pins on the valve body slot into the apertures on the back plate see Fig 6 3 Screw backplate D to bracket A with fixing screws D1 4 Fix the valve body E to the backplate D with clips F and screws F1 Do not use excessive force to tighten the screws F1 5 Align the valve with the bracket horizon tally vertically and parallel to the wall by using a...

Page 8: ...rk and connections to the pressure balance valve for leaks Reinstall fitting template for finishing wall surface 8 Observe the installation depth in accor dance with the instructions given on the fitting template see Figs 8 for Head shower and 9 for Handshower 9 Fitting template must remain intact for finished wall surface measurements and as a template for plastering and or tiling On tiled wall s...

Page 9: ...s fitted against a particularly rough surface deep tile joints highly textured tile 6 Tighten the wall plate screws 7 Push adjustable hot water limit stop K to the intermediate ring M as described in Fig 13 Please refer to chapter Maximum Hot Water Limit Setting on page 13 for limiting maximum outlet temperature 8 Push the handle L on the intermediate handle M so that the OFF position on the wall ...

Page 10: ...idge O out of the valve body Do not damage the O ring seals see Fig 16 8 Reverse the pressure balancing cartridge 180 by turning it upside down Place it into the valve body Ensure the two alignment pins O1 on the rear of the pressure balancing cartridge are properly seated in the holes Z of the valve body Reassemble in reverse order Be sure that the stop ring N is in the previously noted position ...

Page 11: ...ing cartridge O out of the valve body Do not damage the O ring seals see Fig 19 7 Reverse the pressure balancing cartridge 180 by turning it upside down Place it into the valve body Ensure the two alignment pins O1 on the rear of the pressure balancing cartridge are properly seated in the holes Z of the valve body Notice the position of hot H and cold C markings on the cartridge to assure the corr...

Page 12: ... limit stop K 3 Turn the intermediate ring M counter clockwise until the outlet water reaches the desired temperature see Fig 21 4 Place the hot water limit stop K over the splines on the intermediate handle with the limit stop resting against the wall plate stop post see Fig 22 5 Close the valve by turning the intermediate handle M clockwise 6 Reinstall handle as described in Fig 20 in reversed d...

Page 13: ...ut of the valve body noting the location of H and C marking near the cartridge inlets The pressure balancing cartridge O must be replaced as a complete unit Reassemble in reverse order Ensure the two alignment pins O1 on the rear of the pressure balancing cartridge are properly seated in the holes Z of the valve body and that the hot H and cold C markings are on the correct side Be sure that the s...

Page 14: ...surface of our fittings Problem Cause Remedy Shower control opening through hot Hot and cold water supplies have been connected in reverse Rotate cartridge as described in chapter Reversed Supplies Installation Shower head drips after shutting off the valve O ring seal on the inlet of the cartridge is faulty Incorrect setting of the stop ring against the stop pin causing a partially opened cartrid...

Page 15: ...imitations see E F B It is our option if we correct the defects by repair or replacement C During the above guarantee period we will not charge for the cost of parts travel working time freight and packaging needed to effect the correction of defects D If we are not able to correct the defect we are prepared to supply a replacement product E Deliberate or careless damage is not co vered by this gu...

Reviews: