background image

1

English

Safety notes

• Installation is only possible in frost-free rooms.
• The plug-in connectors must 

not

 be directly or indirectly 

sprayed with water when cleaning.

Application

Can be used in conjunction with:

•  Pressurised storage heaters

•  Thermally/hydraulically controlled instantaneous water heaters

Operation with unpressurised storage heaters (displacement 
water heaters) is 

not

 possible.

•  The GROHE Foot control function for switching the water 

flow on or off is based on the principle of electrical charge 
shifting on metallic surfaces. If the solenoid valve is closed 
during Foot control sensing it will be opened, and if the 
solenoid valve is already open it will be closed.

Specifications

•  Flow pressure:

       

- min. 

0.05 MPa

- recommended 

0.1 - 0.5 MPa

•  Operating pressure 

max. 1.0 MPa

•  Test pressure    

1.6 MPa

A pressure reducing valve must be fitted in the supply line if 
static pressures exceed 0.5 MPa to satisfy noise level ratings.

Avoid major pressure differences between cold and hot water 
supply! 

• Temperature hot water inlet: 

max. 158 °F

Recommended (energy saving):

 140 °F

• Thermal desinfection possible

•  Ambient temperature:

39 - 104 °F

• Relative humidity: 

max. 80%

• Voltage supply: 

   6 V lithium battery (type CR-P2)

• Rated power:

1.4 W

• Automatic safety shut-off after Foot control: 

60 s

• Three water pulses indicate that a battery change is 

necessary.

• Type of protection control:

 

IP 44

•  Water connection 

cold - right

hot - left

Approval and conformity

The conformity declarations can be obtained from the following 
address:

GROHE Deutschland Vertriebs GmbH

Zur Porta 9
D-32457 Porta Westfalica

Installation

Refer to fold-out page I for hose lengths and installation 
dimensions.

Caution: 

The control should be easily accessible.

Flush pipes thoroughly before and after installation

 

(observe EN 806).

 

Install bracket with control and connect, 

see fold-out page I, 

Figs. [1] to [11].

The sensor plate must be mounted on plastic or wooden 
surfaces. The distance to metal surfaces must be taken into 
account, see Fig. [5].

Install

 

weight on shower hose,

 see Fig. [12].

Important note
To ensure proper functioning when using metal sinks, 
the sink must be connected to the control via the pre-
assembled yellow hose for potential equalisation,

 

see Fig. [13].

For all other sinks the yellow hose must be connected to 
another suitable metal part for potential equalisation.

Country specific and local regulations must be 
observed.

Putting into service

To prevent the risk of scalding, the outlet 
temperature of the mixer unit should be set to 
lukewarm.
Recommended maximum temperature: 38 °C

,

see Fig. [15].

The spout must always be positioned above the 
sink to prevent water damage.
Ensure free runoff.

Insert battery, 

see fold-out page II, Figs. [14] - [17].

The sequence is important and must be observed.

The electronics will detect ambient conditions. During this time 
the control indicator lamp flashes. The fitting must 

not

 be 

activated (for approx. 1 min.).

Check connections for watertightness.

Check for proper function

, see Fig. [18].

Adjusting 

of Foot control parameters to ambient conditions, 

see fold-out page II, Fig. [19].
- The release varies depending on ambient temperature 

and air humidity. 

- Foot control parameters: 5 highest value... 1 lowest value...
- A value that is too high leads to the risk of continuous 

operation. 

The menu is started by pressing the button at the control unit 
for at least 10 seconds.
•  The indicator lamp flashes once.
•  The last stored value will then be displayed by flashing, 

e.g. three times for level 3 (factory setting).

•  Each time the button is pressed the value goes up one level.
•  The selected level is indicated by the number of flashes.

- If no further buttons are pressed, the indicator lamp signals 

the last set value 2 more times. The lamp then emits a 
continuous signal and the menu is exited. The last stored 
value will be saved. 

This product conforms to the requirements of the 
relevant EU guidelines.

Summary of Contents for 30 310

Page 1: ...ST 22 UA 27 F 3 DK 8 GR 13 SK 18 LV 23 RUS 28 E 4 N 9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com English 1 Fran ais 3 Espa ol 5 GROHE FOOT CONTROL 99...

Page 2: ...e la robinetterie Entregue estas instrucciones al usario final de la grifer a Please pass these instructions on to the end user of the fitting 1 16mm 16mm 16mm 16mm 2 16mm 16mm 16mm 19mm 3 4 5 6 22mm...

Page 3: ...II 15 19 10 sec 20 21 22 19mm 24mm 23 24 19mm 22mm 22mm 24mm 16 17 18 13 14...

Page 4: ...t page I Figs 1 to 11 The sensor plate must be mounted on plastic or wooden surfaces The distance to metal surfaces must be taken into account see Fig 5 Install weight on shower hose see Fig 12 Import...

Page 5: ...reverse order Replacement parts See fold out page III special accessories Care For directions on the care of this fitting please refer to the accompanying Care Instructions Disposal instructions This...

Page 6: ...e doit imp rativement tre mont e sur des surfaces plastiques ou en bois La distance avec les surfaces m talliques doit tre respect e voir fig 5 Monter le poids au niveau du flexible de douche voir fig...

Page 7: ...nge Voir volet III accessoires sp ciaux Entretien Les consignes d entretien de cette robinetterie figurent dans les instructions d entretien ci jointes Remarque sur l limination des d chets Les appare...

Page 8: ...do v ase la p gina desplegable I figs 1 a 11 La placa de sensores debe colocarse sobre superficies de pl stico o madera Se debe tener en cuenta la distancia a las superficies met licas v ase la fig 5...

Page 9: ...z v asela fig 24 El montaje se efect a en el orden inverso Piezas de recambio V ase la p gina desplegable III accesorios especiales Cuidados La informaci n sobre el cuidado del aparato de esta grifer...

Page 10: ...he com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL info malaysia grohe com MX 01800 8391200 pregunta grohe com N 47 22 072070 grohe grohe no NL 31 79 3680133 vragen nl grohe com NZ...

Reviews: