background image

2

English

Temperature limitation

The safety stop limits the temperature range to 100  °F.
If a higher temperature is desired, the 100  °F limit can be overridden by 
pressing the button (J3).

Flow control for side spray,

 see Fig. [15].

Prevention of frost damage

When the domestic water system is drained, thermostats must be drained 
separately, since non-return valves are installed in the hot and cold water 
connections. For this purpose, the shower system must be removed from 
the wall.

Maintenance

For maintenance, see fold-out page V and VI, Figs. [16] to [22].

Inspect and clean all parts, replace if necessary and grease with special 
valve grease (Prod. no. 18 012).

Shut off cold and hot water supply.

II. Side spray with non-return valve (K), 

see Fig. [16].

1.Remove rosette (B3).

2.Remove screw (K1) using a screwdriver.

3.Completely remove spray face plate (K2).

4.Detach housing (K3).

5.Remove washer (K4) by pressing in the ball (K5).

6.Remove ball (K5).

7.Pull out non-return valve (K) using pliers.

Assemble in reverse order.

When installing the washer (K4) the ball (K5) must be pressed slightly into 
the housing.

We guarantee that the SpeedClean nozzles will function unchanged for a 
period of 5 years.

Simply rub SpeedClean nozzles in order to remove limescale deposits 
from spray jet of hand, overhead and side sprays.

Shut off cold and hot water supply.

II. Thermostatic cartridge, 

see fold-out page VI, Fig. [17].

1.Lever out cap (J1).

2.Remove screw (J2).

3.Detach temperature control handle (J).

4.Remove clip (L1).

5.Pull off stop ring (L).

6.Detach regulating nut (M1) with overload unit (M2).

7.Unscrew and remove thermostatic cartridge (M) using a 22mm open-

ended spanner.

Assemble in reverse order. 

Observe the correct installation position.

Readjustment is necessary after every maintenance operation on the 
thermostatic cartridge (see 

Adjustment

).

III. Aquadimmer, 

see fold-out page VI, Fig. [18].

1.Lever out cap (H2).

2.Remove screw (H3) and detach shut-off knob (H).

3.Remove splined adapter (O1) and stop (O2).

4.With a 19mm open-ended spanner, unscrew and remove 

aquadimmer (O).

Assemble in reverse order.

Observe the correct installation position

1.The various pins (O7) and (O8) must project into the relevant apertures 

in the race, see Fig. [19].

2.Attach stop (O2) with mark (O3) pointing downwards, mark (O3) 

and (O4) coincide, see Fig. [20].

3.Attach splined adapter (O1), the faces (O5) coincide in only one 

position.

4.Turn splined adapter (O1) so that the lug (O6) points to the right.

IV. Non-return valve (P), 

see Fig. [21].

1.Lever out caps (H2) and (J1).

2.Remove screws (H3) and (J2) and detach shut-off knob (H) and 

temperature selection handle (J). 

3.Remove rosettes (B3) and retaining rings (B) using installation tool (B1).

4.Detach wall plate (B2).

5.Remove non-return valve (P) using a 17mm socket spanner.

V. Non-return valve (R2) and (R4)

1.Unscrew spray hose (R1). 

2.Remove non-return valve (R2).

3.With a 12mm Allen key, remove outlet nipple (R3).

4.Remove non-return valve (R4).

Assemble in reverse order.

Replacement parts, 

see fold-out page VIII (* = special accessories).

Care

Instructions for care of this faucet will be found in the Limited Warranty 
supplement.

Please pass these instructions on to the user of the fitting.

The right to make technical modifications is reserved.

Reviews: