background image

1

English

Application

In order to ensure correct operation, a pressure of at least 21.75 psi is 
necessary at the shower system.

Caution:

With sufficient power (from 18 kW) electric or gas instantaneous heaters 
are also suitable.
All thermostats are adjusted in the factory at a flow pressure on both sides 
of  45 psi.
Should temperature deviations exist due to special installation conditions, 
the thermostat must be adjusted to the local conditions (see Adjustment).

Specifications

Minimum flow pressure

21.75 psi

Max. working pressure

145 psi

Recommended flow pressure

29.0 - 72.5 psi

Test pressure

232 psi

Flow rate at 3 bar flow pressure
Hand spray

max. flow 9,5 L/min or 2,5 gpm/ 80 psi

Side showers

max. flow 9,5 L/min or 2,5 gpm/ 80 psi

Handspray and side sprays

max. flow 9,5 L/min or 2,5 gpm/ 80 psi

Max. water temperature at hot water inlet

176 °F

Recommended max. flow temperature
(energy saving)

140 °F

Safety check

100 °F

Hot water temperature at supply connection min. 4 °F higher than mixed 
water temperature
Cold water connection

right

Hot water connection

left

If static pressure is greater than 72.5 psi, fit pressure reducer.

Tools required, 

see fold-out page I.

Delivery specification,

 see fold-out page II.

Installation

New installation:

Make up unions.
For union dimensions for cold and hot water connection, see fold-out 
page III Fig. [1].
The cold water supply must be connected on the right and the hot water 
supply on the left.
The installation dimensions of the fitting relate to the standing level of the 
shower stand, see Fig. [2].
The installation height of the showers from the standing level must be 
observed in order to comfortably operate the fitting.

Retrofitting:

Union dimensions must correspond to Fig. [3].
The cold water supply must be connected on the right and the hot water 
supply on the left.
The installation dimensions of the fitting relate to the standing level of the 
shower stand, see Fig. [4].
The installation height of the showers from the standing level must be 
observed in order to comfortably operate the fitting.

Connections and fastenings, 

see fold-out page III and IV, Figs. [1] 

to [10].
For individual components, see delivery specification, Figs. [I] to [IV].
1.Drill  fixing holes for ø 8mm mounting plugs, see Fig. [1] and [3].
2.Install accompanying elbow unions (A). If S-unions are present, remove 

and replace with elbow unions (A), see Fig. [5].

3.Screw in threaded studs (A1) into the elbow unions (A) using roughly 

one turn.

Seal the elbow unions (A) at the tiled wall with sealing compound.

Flush pipes thoroughly

4.

Remove retaining rings (B) with installation tool (B1), 
see Fig. [6].

5.

Detach wall plate (B2).

6.

Insert mounting plug (C1), see Fig. [7].

7.

Guide elbow unions (A) through the area provided in the fitting 

assembly (C) and slide rib (A2) from below behind the lug (A3) of the 
elbow union, see Fig. [8].

8.

Preassemble the fitting assembly (C) with the threaded studs (A1). 

9.

Secure fitting assembly (C) using fixings (C2) supplied, see Fig. [7].

10. Connect hoses (D) with accompanying seals (D1) and elbow 

unions (A), see Fig. [9].

Spray hose, shower rail slider, shower rail and hand spray,

 see fold-

out page IV and V, Fig. [9], [10] and [11].
For individual components, see delivery specification, Figs. [IV], [V], [VI] 
and [VII].

1.Attach spray hose (E) with seal (E1) to elbow unions (E2), see Fig. [9].

2.Slide shower rail slider (F) onto shower rail (F1), see Fig. [10].

3.Insert shower rail (F1) into the fitting assembly (C) and secure using 

screw (F2).

4.Insert bracket (F3) onto the shower rail (F1) and secure using 

screw (F4).

5.Fit cap (F5).

If there is an offset, wall plate 45 406 special accessory can be ordered.

6.Fit handspray (G) to spray hose (E), see fold-out page V, Fig. [11].

Attach wall plate (B2).

1.Insert seals (B4) into the wall plate (B2), note position of seal, see detail 

view in Fig. [12].

2.Slide wall plate (B2) onto the fitting assembly (C), screw on retaining 

rings (B) and tighten using installation tool (B1). 

Note: Keep installation tool (B1) for possible future maintenance work 
on the shower system.

3.Attach rosettes (B3) to the side sprays.

Adjustment

Temperature adjustment, 

see Figs. [13] and [14].

• Before the mixer is put into service if the mixed water temperature 

measured at the point of discharge varies from the specified 
temperature set on the thermostat.

• After any maintenance operation on the thermostatic cartridge. 
Operation of the 

shut-off knob

 (H), see Fig. [13]:

Flow-control knob in central position

= closed   

Flow-control knob clockwise

= discharge from hand spray

Press button (H1) and turn 
shut-off knob anti-clockwise

= discharge from side shower

Press button (H1) and turn 
shut-off knob anti-clockwise fully

= discharge from side shower 

and hand spray

1.Open cold and hot water supplies.

2.Open the shut-off knob (H) to the hand spray position and measure the 

temperature of the running water using a thermometer.

3.Turn the temperature control handle (J) until the water temperature 

reaches 38  °C.

4.Lever out cap (J1), see Fig. [14].

5.Hold thermostat knob (J) in this position and remove screw (J2).

6.Pull off thermostat knob (J) and reinstall in such a way that the 38 °C 

mark on the wall plate (B2) coincides with the mark on the knob.

7.Reinstall screw (J2) and refit cap (J1).