Installation Type #1 19 843

If 

both

 rough-in outlets are used, you have to install a spout 

with

 

diverter

. If only 

the lower

 rough-in outlet is used, you 

have to install a spout 

without

 

diverter

.

1. Install control unit and secure with screws, see Fig. [5].

2. Close valve by turning the adaper (A) clockwise until it 

stops, see Fig. [6].

3. Open the hot and cold integrated service stops.

4. For installation of handle parts, see Fig. [7].

5. While installation observe the right mounting position.

If the pressure balancing valve is installed too deep, 

the 

fitting depth can be increased by 25mm or 1" with an extension 
set, Part No. 47 823, see page II.

Note:

The preset maximum temperature will change if the inlet 
temperatures change or the setting of the water heater 
thermostat is altered or if the water inlet temperature is 
fluctuating.

Operation

Turn lever anti-clockwise: 
- Open from cold to hot water flow, see Fig. [8].
The adjustable hot water limit stop (B) is factory set at a 
position to limit maximum outlet temperature to below the hot 
water supply temperature, see Fig. [7]. For installations where 
there is need to modify the limit temperature, remove the limit 
stop (B) and replace in a more clockwise position for colder 
water, or more counter-clockwise position for hotter water.

Observe the mounting position of stop (C).

6

A

8

5

7

B

C

Summary of Contents for 19 843

Page 1: ...S 7 UAE 12 TR 17 EST 22 UA 27 F 3 DK 8 GR 13 SK 18 LV 23 RUS 28 E 4 N 9 CZ 14 SLO 19 LT 24 I 5 FIN 10 H 15 HR 20 RO 25 DESIGN ENGINEERING GROHE GERMANY www grohe com 19 843 19 844 99 791 031 M 219326...

Page 2: ...ettre cette instruction l utilisateur de la robinetterie Entregue estas instrucciones al usario final de la grifer a Please pass these instructions on to the end user of the fitting I Type 1 19 843 Ty...

Page 3: ...II II Type 1 19 843 Type 2 19 844...

Page 4: ...instructions on to the end user of the faucet without bypass use with use of integrated PBV trim type 1 single use bypass PBV trim type 2 integrated two way diverter Installation options with differen...

Page 5: ...1 5 bar or 14 5 72 5 psi If greater than 5 bar or 72 5 psi fit pressure reducing valve Max operating pressure 8 5 bar or 125 psi Max test pressure 34 5 bar or 500 psi Flow rates at 3 bar or 45 psi Ty...

Page 6: ...be increased by 25mm or 1 with an extension set Part No 47 823 see page II Note The preset maximum temperature will change if the inlet temperatures change or the setting of the water heater thermost...

Page 7: ...ncreased by 25mm or 1 with an extension set Part No 47 823 see page II Note The preset maximum temperature will change if the inlet temperatures change or the setting of the water heater thermostat is...

Page 8: ...n open the flow control to allow any internal pressure to be released from within the unit Inspect and clean all parts replace if necessary and grease with special valve grease Close the integrated se...

Page 9: ...final de la robinetterie utilisation sans d rivation avec utilisation d une quilibreur depression de type 1 usage unique d rivation int gr e quilibreur depression de type 2 inverseur deux voies Option...

Page 10: ...psi recommand e 1 5 bar ou 14 5 72 5 psi Installer un r ducteur de pression lorsque la pression est sup rieure 5 bar ou 72 5 psi Pression de service maxi 8 5 bar ou 125 psi Pression d preuve maxi 34...

Page 11: ...r page II Remarque La temp rature maximale pr r gl e change si les temp ratures d entr e changent si le r glage du thermostat du chauffe eau est modifi ou si la temp rature d entr e d eau fluctue Fonc...

Page 12: ...d eau fluctue Fonctionnement voir fig 9 Tourner le levier D dans le sens inverse des aiguilles d une montre S lect de l coulement d eau froide vers le chaud Tourner le levier E vers la gauche ou la dr...

Page 13: ...r de d bit pour permettre l vacuation de la pression interne de l int rieur de l unit Inspecter et nettoyer toutes les pi ces les remplacer si n cessaire et les graisser avec une graisse pour robinett...

Page 14: ...final del montaje sin derivaci n con derivaci n Tipo mandos de compensaci n de presi n n 1 uso nico integrada Tipo mandos de compensaci n de presi n n 2 inversor de dos v as integrado Opciones de inst...

Page 15: ...ajo m n 1 bar o 14 5 psi recomendado 1 5 bares o 14 5 72 5 psi superior a 5 bar ou 72 5 psi instalar una v lvula reductora de presi n Presi n de utilizaci n m x 8 5 bares o 125 psi Presi n de verifica...

Page 16: ...de producto 47 823 v ase la p gina II Nota La temperatura m xima preconfigurada cambiar si las temperaturas de entrada var an si la configuraci n del termostato del calentador de agua se modifica o s...

Page 17: ...ato del calentador de agua se modifica o si la temperatura de entrada de agua fluct a Funcionamiento v ase la fig 9 Gire la palanca D en el sentido contrario de las agujas del reloj Selecto la salida...

Page 18: ...e caudal para permitir que se alivie cualquier presi n interna desde el interior de la unidad Inspeccione y limpie todos los componentes sustituya los que sean necesarios y lubrique con grasa especial...

Page 19: ......

Page 20: ...0 info grohe co jp KZ 7 727 311 07 39 info cac grohe com LT 372 6616354 grohe grohe ee LV 372 6616354 grohe grohe ee MAL 1 800 80 6570 info singapore grohe com N 47 22 072070 grohe grohe no NL 31 79 3...

Reviews: