When different types of alarm are triggered at the same time, alarms with the highest priority will work
first.
“Alarm 1” default configuration as shown above
Trigger Level
: There are 3 options of Trigger Level. The options “Low” and “High” are used for turning
on alarm function. “Low” is generally used for debugging while “High” will be selected to turn on alarm
function for on-road use. “Off” means turning off alarm trigger function.
Output Duration:
"Display" "Curser" "Alarm Out" effect duration.
Alarm Out-Buzzer
: Switch ON or OFF of the Alarm Out-Buzzer. The default buzzer sounds for 5
seconds.
Alarm Out-Output1
: Set it ON, then 12V level output would come from the alarm wire of Output 1.
Alarm Out-Output2
: Set it ON, then 12V level output would come from the alarm wire of Output 2.
Display
: The selected single channel or dual channels will be in full screen mode once the alarm is
triggered.
Cursor
: It is “OFF” by default. The picture below shows the open state.
①
Camera name of the alarm-triggered channel.
②
Touch this button to turn on/off cursor.