background image

Summary of Contents for Vortex 100 Series

Page 1: ...ids in the vicinity of this or any other appliance NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibi...

Page 2: ...NY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT SERVICE BY OTHER T...

Page 3: ...INSTALLATION INSTRUCTIONS SERVICE LOG References UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook Illinois 60062 NFPA 70 The National Electrical Code NATIONAL SANITATION FOUNDATION 3475 Pl...

Page 4: ...RC 6E holds up to six standard 12 x20 x2 1 2 or four 12 x20x4 steamer pans Inspection and Unpacking The Steamer will be delivered completely assembled in a heavy shipping carton strapped to a skid On...

Page 5: ...upplied with the unit Single phase models are designed to be directly connected hard wired to the electrical supply and allow sufficient loop in the flexible conduit to facilitate inspection servicing...

Page 6: ...the factory If the unit is connected to a drain do not connect more than two units to one drain line or pressure from one unit will effect the second unit Stacking Units Instructions Remove drain con...

Page 7: ...OUBLE STACK STEAM EXHAUST HOSE P N 141505 DOUBLE STACK STAND P N 142363 HOSE CLAMPS P N 073259 B DETAIL B SCALE 1 1 10 32 SCREW P N 004173 DOUBLE STACK STEAM EXHAUST BRACKET ASSEMBLY P N 143243 HOSE C...

Page 8: ...rating The ADD WATER indicator light is lit when it s time to add water The open and closed position of the drain valve allows the unit to be filled with water or drained The ready indicator light ind...

Page 9: ......

Page 10: ...amer off Open the door b Drain the water from the unit into the drain pan and allow the unit to cool before cleaning Note If the cavity is full of water the drain pan will not hold the entire amount a...

Page 11: ...Troubleshooting This Groen Steamer is designed to operate smoothly and efficiently if properly maintained However the following is a list of checks to make in the event of a problem Wiring diagrams a...

Page 12: ...tall the inside tension clamp 3 2 Guide the hose loose end thru the uncovered hole to the outside bottom of the unit as drawing shows 3 3 Thread the hose drain assembly onto the unit drain valve see d...

Page 13: ...MP 6 6 2 GAP MINIMUM 16 DETAIL C SCALE 1 2 1 5 14 ATTACH HOSE 143254 3 8 DIAMETER X 30 LONG TO THIS PORT USING THE TENSION CLAMP 16 ITEM NO 16 14 6 5 4 3 2 1 PART NO 143254 127523 143250 143246 140789...

Page 14: ...e stands and into the threaded holes on the bottom of your steamer 5 To place racks on stand align wires from top of the rack with the corresponding holes in bracket 3 Push the rack all the way up int...