OM-TDB/8-20-CFC 5
OM-TDB/8-20-CFC
Inspection & Unpacking
The unit will arrive in a shipping carton which
Thoroughly inspect the unit for concealed
has been strapped or stapled shut. Immediately
damage. Report any shipping damage or
upon receipt, inspect the carton carefully for
incorrect shipments to the delivery agent.
exterior damage.
CAUTION
SHIPPING STRAPS ARE UNDER TENSION
AND CAN SNAP BACK WHEN CUT. TAKE
CARE TO AVOID PERSONAL INJURY OR
DAMAGE TO THE UNIT BY STAPLES
LEFT IN THE WALLS OF THE CARTON.
Carefully cut the straps around the carton and
detach the sides of the box. Pull the carton up
off the unit.
Write down the model number, serial number,
and installation date, and file this information for
future reference. Space for these entries is
provided at the top of the Service Log on Page
18 of this manual.
When installation is to begin, lift the unit straight
up, obtaining help as needed. Examine packing
materials to be sure loose parts are not
discarded with the materials.
Installation
WARNING
IMPROPER INSTALLATION CAN RESULT
IN INJURY TO PERSONNEL AND/OR
DAMAGE TO EQUIPMENT.
THE UNIT MUST BE GROUNDED. DO
NOT FORCE THE PLUG OR ALTER IT TO
OVERRIDE GROUNDING FEATURES.
The Groen cooker/mixer is provided with
complete internal wiring. It is ready for
immediate connection. The completed unit was
operated at the factory to check the controls,
mixer and jacket heater.
Any mechanical or electrical changes must be
approved in by Groen’s Food Service
Engineering Department.
1. Set the kettle in place and level it.
2. Provide electrical power as specified on the
electrical information plate attached to the
equipment. Observe local codes and/or The
National Electrical Code in accordance with
ANSI/NFPA 70 - (current edition).
3. Confirm that the jacket water level is at the
middle of the sight glass. If the level is low,
use the following procedure for adding water:
a. If you are replacing water lost by
evaporation, use distilled water. To
replace treated water that ran out of the
jacket, prepare more treated water as
described in Water Treatment, Page 9.
b. Remove the plug from the elbow.
c. Add water or treated water through the
elbow, until the water level rises to the
middle of the sight glass. Note that
added water must raise the level in the
whole jacket, so a substantial amount of
water will be needed to make a small
change in the level.
d. Replace the plug in the elbow. Follow
instructions under “Jacket Filling and
Water Treatment” in the “Maintenance”
section of this manual.
OM-TDB/8-20-CFC