background image

OM-TDB/8-20-CFC          11

OM-TDB/8-20-CFC

SYMPTOM

WHO

WHAT TO CHECK

Items marked with (

Y

) should only by done by a factory-authorized service rep.

Motor will not run; kettle does not User

a. Check that plug is firmly plugged into wall outlet.

heat.

b. Check that branch circuit is on.  Check fuse or circuit

breaker for the outlet.  Other equipment on the same

circuit may cause an overload.

Auth

c. Loose wire.

Y

Service

Rep. Only

Motor circuit breaker trips

User

a. Fudge may be too thick.  Lift agitator off the top of the

frequently

shaft and restart the motor.  If the shaft turns, the

fudge is too thick.  Add water until the motor will turn.

Auth

b. Drive shaft bushing binding.  Remove agitator.  Put

Service

two drops mineral oil on top of the shaft on the inside

Rep. Only

of the white plastic bushing.  When you turn on the

motor the bushing should not rotate.  If it does,

replace it.

Y

c. Start/run capacitors reversed.  Check wiring

diagram.

Y

Motor circuit breaker trips

Auth

d. Start relay stuck in closed position.  Measure current

frequently (Continued)

Service

in start winding (red wire).  After motor starts current

Rep. Only

should drop to zero.

Y

Kettle makes grinding noise

Auth

Some amount of noise is normal for this kettle and does

Service

not necessarily indicate a problem..

Rep. Only a. Drive belt may be loose or misaligned.

Y

b. Gearbox pulley not properly secured to shaft.

Y

c. Drive shaft bushing is binding.

Y

NOTE:

Probes and controllers in kettles built before 1989 are not compatible with those built in 1989 or

later.  The earlier controller (silver colored model 1020 — Groen Part Number 072038) must be

used with the probe identified by brown lead wires (Groen Part Number 073414).  The later

version controller (Groen Part Number 

077889)

 must be used with the probe identified by yellow

sleeving on the lead wires (Groen Part Number 

086407),

 or improper heating will result.

Electrical Specifications

Probe Resistance

Before Jan 1, 1989 508 Ohms ± two percent in a stirred ice bath

after Jan 1, 1989

500 Ohms ± one percent in a stirred ice bath

Motor winding resistance at 72ºF

120 Volts

Red to Yellow

23.6 Ohms

Blue to Yellow

  3.1 Ohms

240 Volts

Red to Yellow

19.7 Ohms

Blue to Yellow

15.1 Ohms

No-load running current

120 Volts

1.8 Amperes

240 Volts

1.0 Amperes

Full-load running current

120 Volts

2.5 Amperes

240 Volts

1.3 Amperes

Motor Speed

  60 Hz

3382 RPM at full load

  50 Hz

2810 RPM at full load

Agitator Speed (no-load)

  60 Hz

42 RPM

  50 Hz

35 RPM

Motor start/circuit breaker trip current

120 Volts

2.9 Amperes

249 Volts

1.35 Amperes

Over-temperature switch opening temperature

195ºF ±  6ºF

Heater Power 120 Volts and 240 Volts

1850 Watts

11

OM-TDB/8-20-CFC

Summary of Contents for TDB/8-20-CFC

Page 1: ...D IN THIS MANUAL FOR YOUR SAFETY Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibili...

Page 2: ...CTIVE OVEN MITT AND PROTECTIVE APRON 2 USE CONTAINER DEEP ENOUGH TO CONTAIN AND MINIMIZE SPLASHING 3 PLACE CONTAINER ON STABLE FLAT SURFACE AS CLOSE TO KETTLE AS POSSIBLE 4 DO NOT STAND IN POUR PATH O...

Page 3: ...Paul Minnesota 55102 Ann Arbor Michigan 48106 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION UNDERWRITERS LABORATORIES INC 60 Battery March Park 333 P ngsten Road Quincy Massachuse...

Page 4: ...d rim and a protection The agitator continuously sweeps the butterfly shaped pouring lip It is fitted with an side and bottom of the kettle integral water jacket The kettle exterior has a bright semi...

Page 5: ...TO OVERRIDE GROUNDING FEATURES The Groen cooker mixer is provided with complete internal wiring It is ready for immediate connection The completed unit was operated at the factory to check the contro...

Page 6: ...e sight glass If the level is low see Jacket Filling in the Maintenance Cleaning section of this manual CAUTION DO NOT OPERATE THE KETTLE WHEN THE WATER LEVEL IN THE JACKET IS LOW YOU MAY BURN OUT THE...

Page 7: ...FOLLOW THE DIRECTIONS ON THE CLEANER LABEL 3 Procedure a Clean food contact surfaces as soon as possible after use If the unit is in continuous use thoroughly clean and sanitize the interior and exte...

Page 8: ...Maintenance NOTICE Contact Groen or an authorized Groen representative when repairs are required 1 Periodic Maintenance A Maintenance Service Log is provided at the back of this manual Each time ther...

Page 9: ...strip of pH test paper on the rim of the container Allow about one inch of the strip below the surface of the water c Measure the water treatment compound you will be using One way to do this is to a...

Page 10: ...be faulty or open The switch should open at 195 F Y e Defective temperature controller Y f Loose wire Y Kettle will not heat but heating User a Check for proper water level Fill as necessary See indic...

Page 11: ...ice not necessarily indicate a problem Rep Only a Drive belt may be loose or misaligned Y b Gearbox pulley not properly secured to shaft Y c Drive shaft bushing is binding Y NOTE Probes and controller...

Page 12: ...12 OM TDB 8 20 CFC 12 OM TDB 8 20 CFC PARTS LIST Units Build before January 1 1989 OM TDB 8 20 CFC...

Page 13: ...motor starting 115v 074518 54 Bearing agitator 072049 11 1 4 20 kep nut 012940 33 6 32x3 16 lg rd hd mach screw 058599 55 Lamp pilot 115v 1 3w 002986 12 Spacer 072040 34 6 32x5 8 lg rd hd mach screw...

Page 14: ...PARTS LIST Units Built after January 1 1989 57 56 40 55 62 65 64 63 1 60 45 46 48 42 54 50 44 43 47 32 39 38 37 53 34 59 52 33 29 30 35 28 31 34 41 58 61 13 17 15 18 26 25 23 24 33 4 14 19 3 5 2 12 36...

Page 15: ...4511 20 Shaft 072064 072028 30 Capacitor 25 F 074510 21 Coupling 072058 072026 31 Terminal block 056746 22 Spring Pin 5 32 x 1 3 8 ss 072062 072027 32 Relay motor starting 115v 074518 23 Un anged pull...

Page 16: ...16 OM TDB 8 20 CFC Electrical Schematic Units built before January 1 1989 16 OM TDB 8 20 CFC...

Page 17: ...HZ 14 Ga 14 Ga 14 Ga ALL WIRES 18 AWG UNLESS NOTED 22 Ga GND CORD PLUG 12 AWG AC1 AC2 R1 R2 TS1 TS2 LOW 140 F MED 160 F HIGH 180 F 086408 REV G 2 7 NOTE MINIMUM 15K RESISTOR MAY BE EXTERNAL OR INTERN...

Page 18: ...18 OM TDB 8 20 CFC 18 OM TDB 8 20 CFC ELECTRICAL SCHEMATIC FOR Units built from July 1 2003 through December 2005...

Page 19: ..._________ Serial No _____________________________ Location _______________________________ Date Purchased _________________________ Date Installed ___________________________ Purchase Order No _______...

Page 20: ..._ Serial No _____________________________ Location _______________________________ Date Purchased _________________________ Date Installed ___________________________ Purchase Order No _______________...

Page 21: ..._________ Serial No _____________________________ Location _______________________________ Date Purchased _________________________ Date Installed ___________________________ Purchase Order No _______...

Page 22: ..._ Serial No _____________________________ Location _______________________________ Date Purchased _________________________ Date Installed ___________________________ Purchase Order No _______________...

Page 23: ...of installation or fifteen 15 months from date of shipment from Groen For TDB 8 20 CFC equipment sold to Calico Cottage Inc furthermore Groen will absorb the cost of replacement parts for a period of...

Page 24: ...mber 121027 Rev C 1055 Mendell Davis Drive Jackson MS 39272 Telephone 601 373 3903 Fax 601 373 9587 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 groen com PART...

Reviews: