background image

OPERATOR MANUAL

IMPORTANT INFORMATION, KEEP FOR OPERATOR

PART NUMBER 145144, REV. H (12/07)

1055 Mendell Davis Drive 

Jackson, MS 39272

888-994-7636,  fax 888-864-7636

groen.com

  .

E

C

N

E

R

E

F

E

R

 

E

R

U

T

U

F

 

R

O

F

 

D

E

N

I

A

T

E

R

 

E

B

 

T

S

U

M

 

L

A

U

N

A

M

 

S

I

H

T
READ,  UNDERSTAND  AND  FOLLOW  THE  INSTRUCTIONS  AND 
WARNINGS CONTAINED IN THIS MANUAL.

FOR YOUR SAFETY

Do not store or use gasoline or other flammable vapors 

and liquids in the vicinity of this or any other appliance.

POST IN A PROMINENT LOCATION

Instructions to be followed in the event user smells gas.  

This  information  shall  be  obtained  by  consulting  your 

local gas supplier.  As a minimum, turn off the gas and 

call your gas company and your authorized service agent.  

Evacuate all personnel from the area.

WARNING

Improper  installation,  adjustment,  alteration,  service  or 

maintenance can cause property damage, injury or death.  

Read the installation, operating and maintenance instructions 

thoroughly before installing or servicing this equipment.

NOTIFY CARRIER OF DAMAGE AT ONCE

It is the responsibility of the consignee to inspect the container upon receipt of 
same and to determine the possibility of any damage, including concealed dam-
age. 

Unified

 Brands suggests that if you are suspicious of damage to make a 

notation on the delivery receipt. It will be the responsibility of the consignee to 

file 

a claim with the carrier. We recommend that you do so at once.

Manufacture Service/Questions 888-994-7636.

Information contained in this document is known to be current and accurate at the time 

of  printing/creation.    Unified  Brands  recommends  referencing  our  product  line  websites, 

unifiedbrands.net, for the most updated product information and specifications.

This manual provides information for:

MODELS SSB-3G/5G/10G

& (2)SSB-3G/5G/10G 

Domestic

SMARTSTEAM100

 

BOILERLESS STEAMER

· Self Contained
· Gas Heated
· Capacity:  SSB-3G=3 Steamer Pans Per Cavity

 

       SSB-5G=5 Steamer Pans Per Cavity

 

       SSB-10G=10 Steamer Pans Per Cavity

PART NUMBER 145144, REV. L (10/09)

Summary of Contents for SMARTSTEAM100 (2)SSB-10G

Page 1: ...ion operatingandmaintenanceinstructions thoroughly before installing or servicing this equipment NOTIFY CARRIER OF DAMAGE AT ONCE It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed dam age Unified Brands suggests that if you are suspicious of damage to make a notation on the delivery receipt It w...

Page 2: ...ING THE OUTSIDE OF THE STEAMER DISCONNECT THE ELECTRIC POWER SUPPLY KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL COMPONENTS NEVER HOSE OR STEAM CLEAN ANY PART OF THE UNIT WARNING ALLOW COOKING CHAMBER TO COOL COMPLETELY BEFORE CLEANING WARNING USE MILD CLEANING AGENTS ONLY CAREFULLY READ THE WARNINGS AND FOLLOW THE DIRECTIONS ON THE LABEL OF EACH CLEANING AGENT USE SAFETY GLASS...

Page 3: ...19 References UNDERWRITERS LABORATORIES INC NATIONAL FIRE PROTECTION ASSOCIATION 333 Pfingsten Road 60 Batterymarch Park Northbrook Illinois 60062 Quincy Massachusetts 02269 NFPA 70 The National Electrical Code NFPA 54 The National Fuel Gas Code NATIONAL SANITATION FOUNDATION 3475 Plymouth Road Ann Arbor Michigan 48106 SERVICE LOG 20 WARRANTY PROTECTION 21 NSF INTERNATIONAL 789 N Dixboro Rd P O Box...

Page 4: ...d Pull the carton up off the unit Be careful to avoid personal injury or equipment damage from staples which might be left in the carton walls The SSB 3G 5G 10G steamers are equipped with electronic controls These units are readily identified by their unique control panels Steamer function is controlled by touch pad controls and a rotary timer dial The drain system on all models includes a spray co...

Page 5: ...h has test pressures in excess of 1 2 PSI 3 45 kPa 2 Electrical Supply Connection Provide 115 VAC 60 HZ 1 PH 15 AMP service Bring wire in through hole in the lower left back panel Each cavity requires a separate cord for connections Local codes and or the National Electrical Code should be observed in accordance with ANSI NFPA 70 AN ELECTRICAL GROUND IS REQUIRED The wiring diagram is located in th...

Page 6: ... basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA NOTE Local code may also require check valves in the water supply line 5 Drain Connection Level the steamer front to back and pitch it slightly to the rear maximum 1 4 inch by adjusting the optional legs or the bullet feet on th...

Page 7: ...ch steamer unit must have it s own branch circuit protection C Gas Connection A single gas connection is required for both steamers Gas supply must be adequate under all conditions as listed on page 6 D Drain Connection Steamers must be leveled front to back and pitched to the front maximum 1 4 inch by adjusting the bullet feet on the cabinet or stand base For all factory stacked SSB steamers a 21...

Page 8: ...he ON switch on the control panel 6 When the steam generating reservoir has filled with water the main burners will ignite automatically Within 20 minutes or less the READY light will come on indicating that the water has reached its standby temperature When the READY light is displayed you may take any one of the following steps a Push TIMED and set the timer knob to the desired steaming time b Pu...

Page 9: ...e the steam generator stays at a low boil or ready temperature 2 When the TIMED button is pushed the TIMED light will illuminate and time can be set by turning the TIMER knob cook time can be increased or decreased at any time by turning the timer knob The unit steams until the timer counts down to zero and the temperature drops to ready At that time the STOP light illuminates and a beeper sounds ...

Page 10: ... you want to steam continuously push the MANUAL button The unit will continue steaming until stopped Push STOP to stop producing steam To remove pans from cavity open the door Remove the pans from the steamer using hot pads or oven mitts to protect your hands from the hot pans 2 3 4 5 WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM THE STEAM COMING OUT OF THE UNIT THE STEAM CAN CAUSE BURNS 6 To shut...

Page 11: ... must be done in order to enhance the performance and prolong the life of your SmartSteam Boilerless Steamer IMPORTANT DO NOT USE ANY METAL MATERIAL SUCH AS METAL SPONGES OR METAL IMPLEMENTS SUCH AS A SPOON SCRAPER OR WIRE BRUSH THAT MIGHT SCRATCH ANY STAINLESS STEEL SURFACE SCRATCHES MAKE THE SURFACE HARD TO CLEAN AND PROVIDE PLACES FOR BACTERIA TO GROW DO NOT USE STEEL WOOL WHICH MAY LEAVE PARTI...

Page 12: ...n refer to deliming instructions below S STEP 8 Remove drain strainer and clean thoroughly to remove any build up of debris TEP 9 Replace pan racks and steam lid Steamer is now cleaned and ready to use DELIMING INSTRUCTIONS When using Groen Boilerless Water Filtration System use vinegar as a deliming agent Groen approved delimer may be used to remove excessive scale build up STEP 1 After following...

Page 13: ... steamer door securely closed 6 No steam User a Is the ON switch depressed b Is the water supply connected c Is the water turned on d Is steamer door completely closed 7 Fault Display 7 User a The component cooling fan may not be operating The display may come on for several minutes during normal operation If it stays on for more than 30 minutes call service technician Unit may be used for cooking...

Page 14: ... or unplug from power Turn unit back on 9 Door pops open User a Ensure drain and vent are not plugged No more than two units should be attached to a single drain line b Check door pin adjustment per above c Call service technician 10 Fault Display 6 User a Wait 30 minutes for unit to cool down b Call service technician 14 OM SSB G ...

Page 15: ...OM SSB G 15 PARTS LIST SSB 3G 5G 10GF ...

Page 16: ...16 OM SSB G PARTS LIST SSB 3G 5G 10GF ...

Page 17: ...OM SSB G 17 PARTS LIST SSB 3G 5G 10GF ...

Page 18: ...ntrol Board 160648 25 Motor Assembly 146880 26 Relay Board 160649 27 Ignitor 3G 5G 143559 Ignitor 10G 149009 28 Flame Sense 143673 29 Burner 3G 5G 143976 Burner 10G 145074 Key Description Part No 30 Top Panel 3G 5G 150637 Top Panel 10G 149444 31 Front Panel Overlay 3G 153015 Front Panel Overlay 5G 10G 153472 32 Door Latch Pin 078914 33 Door Pin Lock Nut 003823 34 Steam Lid 3G 5G 149299 Steam Lid 1...

Page 19: ...OM SSB G 19 WIRING DIAGRAM SSB 3G 5G 10GF ...

Page 20: ...___________________ Purchased From ______________________ Serial No ___________________________ Location _____________________________ Date Purchased_______________________ Date Installed_________________________ Purchase Order No ____________________ For Service Call _______________________ 20 OM SSB G ...

Page 21: ...lled a Groen PureSteem Water Treatment System for use in connection with such Groen Convection Combo Steamer Oven HyPerSteam Convection Steamer or HyPlus Pressureless Steamer on or before teh date such Groen Equipment was installed b the original purchaser user has continuously used such Water Treatment System in connection with such Groen Equipment from the date of installation and c the commerci...

Page 22: ... Limited Extended Warranty Coverage is available on all standard Groen Equipment other than CapKold foodservice equipment covered by the above Groen Limited Warranty Commercial purchasers users of Groen Equipment may elect to extend the standard limited warranty to cover parts labor and portal to portal transportation costs time and mileage for an additional i 2000 actual operating hours or ii twe...

Page 23: ...18 OM SSB G 16 OM SSB 3G 5G 10GF NOTES OM SSB G 23 ...

Page 24: ...1055 Mendell Davis Drive s Jackson MS 39272 888 994 7636 s 601 372 3903 s Fax 888 864 7636 groen com PART NUMBER 145144 REV H 12 07 PART NUMBER 145144 REV L 10 09 ...

Reviews: