background image

OM-GSSP-BL-E BOILERLESS STEAMER

IMPORTANT - READ FIRST - IMPORTANT

WARNING:   THE UNIT MUST BE INSTALLED BY PERSONNEL QUALIFIED TO WORK WITH 

ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN CAUSE 

INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE UNIT 

MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES.

CAUTION:   SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.
CAUTION:   DO NOT INSTALL THE UNIT IN ANY WAY WHICH WILL BLOCK THE REAR 

VENTS, OR WITHIN 2 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, 

DEEP FRYER, CHAR BROILER OR KETTLE.

CAUTION:   LEVEL THE UNIT FRONT TO BACK, AND PITCH IT SLIGHTLY TO THE FRONT, 

TO AVOID DRAINAGE PROBLEMS.

WARNING:  FOLLOW THE WIRING DIAGRAM EXACTLY WHEN CONNECTING A UNIT TO 

AVOID DAMAGE OR INJURY. WIRING DIAGRAM IS LOCATED ON THE INSIDE 

OF THE RIGHT PANEL.

CAUTION:   DO NOT USE PLASTIC PIPE. DRAIN MUST BE RATED FOR BOILING WATER.
WARNING:   DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN.
WARNING:   BLOCKING THE DRAIN IS HAZARDOUS.
IMPORTANT:  IMPROPER DRAIN CONNECTION WILL VOID WARRANTY.
IMPORTANT:  DO NOT ALLOW ANY WATER TRAPS IN THE DRAIN LINE. A TRAP CAN CAUSE 

PRESSURE TO BUILD UP INSIDE THE CAVITY DURING STEAMING, WHICH 

WILL MAKE THE DOOR GASKET LEAK.

WARNING:  WHEN YOU OPEN THE DOOR, STAY AWAY FROM STEAM COMING OUT OF 

THE UNIT. STEAM CAN CAUSE BURNS.

WARNING:  BEFORE CLEANING THE OUTSIDE OF THE STEAMER, DISCONNECT THE 

ELECTRIC POWER SUPPLY. KEEP WATER AND CLEANING SOLUTIONS OUT 

OF CONTROLS AND ELECTRICAL COMPONENTS. NEVER HOSE OR STEAM 

CLEAN ANY PART OF THE UNIT.

INSPECTION & UNPACKING

 

CAUTION:  SHIPPING STRAPS ARE UNDER TENSION AND CAN SNAP BACK WHEN CUT.

Your Groen Boilerless Steamer will be delivered completely assembled in a heavy 
shipping carton strapped to a skid. On receipt, inspect carton carefully for exterior 
damage.
Carefully cut the straps and detach the sides of the carton from the skid. Pull the 
carton up off the unit. Be careful to avoid personal injury or equipment damage 
from staples which might be left in the carton walls.
When starting installation, check packing materials to make sure loose parts such 
as the condensate drip tray are not discarded with this material.
Write down the model number, serial number and installation date. Keep this 
information for reference. Space for these entries is provided at the top of the 
Service Log in the back of this manual. This information will also be available 
under MENU

à

UNIT INFO.

INSTALLATION & START-UP

WARNING:  THE UNIT MUST BE INSTALLED BY PERSONNEL WHO ARE QUALIFIED TO 

WORK WITH ELECTRICITY AND PLUMBING. IMPROPER INSTALLATION CAN 

CAUSE INJURY TO PERSONNEL AND/OR DAMAGE TO THE EQUIPMENT. THE 

UNIT MUST BE INSTALLED IN ACCORDANCE WITH APPLICABLE CODES. THE 

UNIT MUST BE INSTALLED BY A LICENSED PLUMBER WHEN INSTALLED 

WITHIN THE COMMONWEALTH OF MASSACHUSETTS.

CAUTION:  DO NOT INSTALL THE UNIT WITH THE REAR VENTS BLOCKED OR WITHIN 2 

INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN, DEEP FAT FRYER, 

CHARBROILER OR KETTLE.

 

TO AVOID DRAINAGE PROBLEMS, LEVEL THE UNIT FRONT TO BACK, AND 

PITCH SLIGHTLY TO THE FRONT.

INSTALLATION

Minimum Clearances: Boilerless Steamer requires the following minimum 
clearances to any surface, combustible or noncombustible.
Right Side: 2 inches       Left Side: 2 inches         Rear: 6 inches

WARNING:   ALLOW STEAMING CHAMBER TO COOL COMPLETELY BEFORE CLEANING.
WARNING:  USE MILD CLEANING AGENTS ONLY. CAREFULLY READ THE WARNINGS AND 

FOLLOW THE DIRECTIONS ON THE LABEL OF EACH CLEANING AGENT. USE 

SAFETY GLASSES AND RUBBER GLOVES AS RECOMMENDED BY CLEANING 

AGENT MANUFACTURER.

WARNING:   DO NOT PUT HANDS OR TOOLS INTO THE STEAMING CHAMBER UNTIL THE FAN 

HAS STOPPED TURNING.

WARNING:   DO NOT OPERATE THE UNIT UNLESS THE REMOVABLE RIGHT SIDE PANEL HAS 

BEEN RETURNED TO ITS PROPER LOCATION.

NOTICE:    DO NOT USE A CLEANING AGENT THAT CONTAINS ANY SULFAMIC ACID, OR 

ANY CHLORIDE, INCLUDING HYDROCHLORIC ACID. IF THE CHLORIDE CONTENT 

OF ANY PRODUCT IS UNCLEAR, CONSULT THE MANUFACTURER. DO NOT 

USE A CLEANING OR DELIMING AGENT THAT CONTAINS MORE THAN 30% 

PHOSPHORIC ACID.

NOTICE:    DO NOT USE ANY DEGREASER THAT CONTAINS POTASSIUM HYDROXIDE OR 

SODIUM HYDROXIDE OR THAT IS ALKALINE.

WARNING:   USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN 

OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN 

RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT. 

SERVICE BY OTHER THAN FACTORY-AUTHORIZED PERSONNEL WILL VOID ALL 

WARRANTIES.

WARNING:  HIGH VOLTAGE EXISTS INSIDE CONTROL COMPARTMENTS. DISCONNECT 

FROM BRANCH CIRCUIT BEFORE SERVICING. FAILURE TO DO SO CAN RESULT 

IN INJURY OR DEATH.

Steam Free Zone: The Boilerless Steamer can be damaged by steam from external 
sources. Do not install the steamer over a steam venting drain. Ensure that steam 
is not present in an area bounded by the footprint of the steamer and a circle 18 
inches in radius about the right rear corner of the steamer (see figure below).

ELECTRICAL SUPPLY CONNECTION

CAUTION:  EACH UNIT MUST HAVE A SEPARATE GROUND WIRE FOR SAFE OPERATION.
WARNING:  TO AVOID DAMAGE OR PERSONAL INJURY, FOLLOW THE WIRING DIAGRAM 

EXACTLY

Bring wire in through hole in the upper left back panel. Each cavity requires a separate 
cord for connections. Local  codes  and/or  the  National  Electrical  Code  should  be  
observed  in  accordance with ANSI/NFPA 70. AN ELECTRICAL GROUND IS REQUIRED. 
The wiring  diagram  is  located  in  the  service  compartment.   
1.   Panel Removal (Right Side): Open the wiring and control panel by removing 

screws from the right side panel.  Lower panel below top cover panel. Pull 
away toward the front of the unit and set aside. 

Summary of Contents for SMARTSTEAM GSSP-BL-10ES

Page 1: ...tterymarch Park Quincy Massachusetts 02169 7471 NFPA 70 National Electrical Code NSF INTERNATIONAL 789 N Dixboro Rd P O Box 130140 Ann Arbor Michigan 48105 9723 888 994 7636 fax 888 864 7636 unifiedbrands net The information in this document is Confidential and shall not be disclosed to any third party without the express written consent of Unified Brands Information contained in this document is ...

Page 2: ...TH APPLICABLE CODES THE UNIT MUST BE INSTALLED BY A LICENSED PLUMBER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS CAUTION DO NOT INSTALL THE UNIT WITH THE REAR VENTS BLOCKED OR WITHIN 2 INCHES OF A HEAT SOURCE SUCH AS A BRAISING PAN DEEP FAT FRYER CHARBROILER OR KETTLE TO AVOID DRAINAGE PROBLEMS LEVEL THE UNIT FRONT TO BACK AND PITCH SLIGHTLY TO THE FRONT INSTALLATION Minimum Clearances...

Page 3: ...ith the basic plumbing code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA NOTE Local code may also require check valves in the water supply line DRAIN CONNECTION WARNING DO NOT CONNECT THE DRAIN DIRECTLY TO A BUILDING DRAIN BLOCKING THE DRAIN IS HAZARDOUS CAUTION DO NOT USE PLASTIC PIPE DRAIN ...

Page 4: ... CAN CAUSE BURNS START UP After the Boilerless Steamer has been installed test it to ensure that the unit is operating correctly 1 Remove all literature and packing materials from the interior and exterior of the unit 2 Make sure the water supply line is open 3 Turn on electrical service to the unit The steamer will not operate without electrical power Do not attempt to operate the unit during a p...

Page 5: ... 1m will no longer be available NOTE TIMED mode can be entered before pre heating has been completed but a warning screen will appear for confirmation that the user wants to proceed to the TIMED mode before the unit is to temperature or not NOTE Time is paused when the door is open only if COMPENSATING TIMER is turned ON Go to MENUàSETTINGS MANUAL MODE Manual Pan Timers 12 00pm Steaming In Progres...

Page 6: ...tire steamer cavity to remove food and scale particles Carefully clean probes if food residue or loose scale is present A thin layer of tightly bound scale is normal and will not affect steamer performance If scale is excessive then refer to deliming instructions below 7 Clean cup and overflow drains per instructions in Cup Overflow Drains section 8 Remove drain strainer and clean thoroughly to re...

Page 7: ... the drain receptacle and not being blocked and backing up into the steamer cavity If the cup and overflow drains is clogged such that the cleaning brush will not clear the blockage or if water cannot move through the cup and overflow drains into the drain receptacle without backing up into the steamer cavity then a service call needs to be made and all use of the steamer must be discontinued unti...

Page 8: ...DE ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE NOR ARE THERE ANY OTHER WARRANTIES EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE In no event shall UNIFIED BRANDS be liable for damages or delay or for any consequential special or contingent damages arising out of any breach of our warranty whether or not we have know...

Page 9: ...9 OM GSSP BL E BOILERLESS STEAMER Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By ...

Reviews: