OM-HY/6E       13

Maintenance

HY-6E Steamers are designed for minimum maintenance, and no user adjustments 

should be necessary. Certain parts may need replacement after prolonged use. If 

there is a need for service, only Groen personnel or authorized Groen representatives 

should perform the work.  Always supply water with a low mineral count that meets the 

standards outlined in the Water Conditioning section of this manual.

If steam or condensate is seen leaking from around the door, take the following steps:

1.   Check the door gasket. Replace if it is cracked or split.

2.   Inspect the cooking chamber drain to be sure it is not blocked.

3.   Adjust the latch pin to allow for changes that might occur as the gasket ages.

a. 

Loosen the lock nut at the base of the latch pin. Turn the latch pin ¼ turn 

clockwise, and re-tighten the lock nut.

b.   After adjustment, run the unit to test for further steam leakage.

c.   If there is still leakage, repeat the adjustment.

d.   Continue adjusting the pin clockwise until the door fits tightly enough to 

prevent leakage.

NOTE

THE UNIT CONTAINS NO FUSES THAT SHOULD 

BE REPLACED BY THE OPERATOR.

Troubleshooting

This Groen Steamer is designed to operate smoothly and efficiently if properly maintained. However, the following is a list of

checks to make in the event of a problem. Wiring diagrams are furnished inside the service panel. If an item on the check list

is marked with (X), it means that the work should be done by a factory-authorized service representative.

SYMPTOM

WHO

WHAT TO CHECK

Steam generator does not fill 

with water.

User

a. Is the ON switch depressed?

b. Is the water supply connected?

c. Is the water turned on?

d. Check for low water pressure (less than 30 PSI or 210 kPa) OR low 

water flow (less than 5.7 liters (1.5 gallons) per minute.

e. Is the screen at the water connection clogged?

f. Has the steam generator been delimed?

No steam.

User

a. Is the ON switch depressed?

b. Is the water supply connected?

c. Is the water turned on?

d. Are steamer doors open?

e. Is the steam generator limed up?

Service light comes on after four 

minutes.

User

a. Is the water supply connected?

b. Is the water turned on?

c. Has the unit been delimed? (Refer to Cleaning Section)

Excessive steam escaping from 

rear of unit.

User

a. Is the water spray hose kinked or obstructed?

Authorized 

Service Rep Only

b. Is the water spray solenoid connected? X

c. Is the drain properly vented? X

High Limit Indicator Light is 

“ON.”

Authorized 

Service Rep Only

Reset the high limit thermostat after checking the

cause of high temperature and correcting it. (X)

(See Service Section)

Summary of Contents for HYPERSTEAM HY-6E

Page 1: ...ONS AND WARNINGS CONTAINED IN THIS MANUAL WARNING FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WARNING Improper ins...

Page 2: ...NY WATER TRAPS IN THE DRAIN LINE A TRAP CAN CAUSE PRESSURE TO BUILD UP INSIDE THE CAVITY DURING STEAMING WHICH WILL MAKE THE DOOR GASKET LEAK WARNING WHEN YOU OPEN THE DOOR STAY AWAY FROM STEAM COMING...

Page 3: ...EN OR THEIR AUTHORIZED DISTRIBUTOR VOIDS ALL WARRANTIES AND CAN RESULT IN BODILY INJURY TO THE OPERATOR AND DAMAGE THE EQUIPMENT SERVICE BY OTHER THAN FACTORY AUTHORIZED PERSONNEL WILL VOID ALL WARRAN...

Page 4: ...vice Log page 29 UNDERWRITERS LABORATORIES INC 333 Pfingsten Road Northbrook IL 60062 NSF INTERNATIONAL P O Box 130140 789 N Dixboro Road Ann Arbor MI 48105 USA NFPA NATIONAL FIRE PROTECTION ASSOCIATI...

Page 5: ...s a spray condenser which helps keep steam from escaping down the condensate drain Equipment Description The HY 6E has two independent cavities each with its own base mounted steam generator Inspectio...

Page 6: ...rk The best way to prevent scale is to supply the purest possible water 2 If your water contains scale forming minerals as most water does use a well maintained water treatment system Whether an excha...

Page 7: ...hematic on the inside of the unit s right side cover gives directions for proper connection of the terminal block jumpers The specified wire must be used or the unit will not meet Underwriters Laborat...

Page 8: ...feed line is inch Use a washer in the hose connection Do not allow the connection to leak no matter how slowly If you have the dual water connection option put the treated water softened to the right...

Page 9: ...cator light comes on when the steam generator is too hot The unit will automatically shut off and cannot be turned on again until the steam generator cools and the HI TEMP indicator light goes out 7 T...

Page 10: ...et the timer for that period The timer will automatically run the steamer for the set time and then turn it off A red light will come on and a beeper will sound Steam production stops To steam continu...

Page 11: ...Funnel PROCEDURE 1 Outside a Prepare a warm solution of the mild detergent as instructed by the sup plier Wet a cloth with this solution and wring it out Use the moist cloth to clean the outside of t...

Page 12: ...r will beep STEP 7 Press ON OFF to turn steamer off Let cavity cool for 5 minutes or longer Open door wipe out inside of cavity and wipe door gasket Close door STEP 8 To use steamer press ON OFF When...

Page 13: ...y and efficiently if properly maintained However the following is a list of checks to make in the event of a problem Wiring diagrams are furnished inside the service panel If an item on the check list...

Page 14: ...ON FRONT LEFT AND RIGHT HY 6 Z096845 4 INSULATION TOP HY 6 Z096846 5 PANEL FRONT LEFT SIDE Z094139 6 SCREW TRUSS HEAD 1 4 20 1 2 LONG Z012700 7 DOOR ASSEMBLY HY 6 130858 8 SCREW HEX HEAD CAP 1 4 20 1...

Page 15: ...6 CAM DOOR UNLATCH LIFT Z074252 7 SCREW PHILLIPS HEAD 8 32 3 8 LONG 129732 8 SPACER DOOR LATCH 130865 9 SPRING Z078911 10 MANDREL SPRING 130864 11 WELDMENT MAGNET RETENTION 130866 12 MAGNET DOOR Z0697...

Page 16: ...CONTACTOR 3 POLE 24VAC 30FLA 148102 3 BRACKET CONTACTOR HY 6E 148578 4 SCREW SLOTTED WASHER HEAD HEX CAP 8 32 1 4 LONG Z074242 5 SCREW SLOTTED WASHER HEAD HEX CAP 10 32 3 8 LONG Z069773 6 BRACKET 1198...

Page 17: ...TO 8 AWG 106412 9 SCREW SLOTTED WASHER HEAD HEX CAP 10 32 1 4 LONG Z072104 10 BUSHING SNAP 1 ID Z097015 11 BUSHING SNAP 11 16 ID Z012864 12 LID CHASSIS 119896 13 SCREW SLOTTED WASHER HEAD HEX CAP 8 3...

Page 18: ...4 LONG 119827 10 HARNESS TIMER MOTOR 123120 11 HARNESS JUMPER CON TROL TO RIBBON CABLE 123122 12 COVER CONTROL PANEL 143255 13 ASSEMBLY CONDUIT AC SUPPLY HY 6E 140882 14 HARNESS CONTROL LOWER CAVITY 1...

Page 19: ...ER MOTOR COVER ASSEMBLY Key Description Part 1 INSULATOR MOTOR Z094135 2 ASSEMBLY MOTOR BLOWER 146880 3 ASSEMBLY WHEEL BLOWER Z096790 4 SEAL MOTOR Z096868 5 LUBRICANT SHAFT SEAL 6 WIREFORM NT1869 7 AS...

Page 20: ...INET STEAM GENERATOR ASSEMBLY Key Description Part 1 WELDMENT CABINET HY 6 125727 2 ASSEMBLY STEAM GENERA TOR 141481 3 TOP CABINET Z094198 RAIL LOWER CENTER Z094171 RAIL LOWER REAR Z094172 SCREW HEX H...

Page 21: ...CKET SUPPORT REAR COVER Z094137 12 BRACE BACK Z094186 13 WELDMENT REAR COVER 139940 14 SCREW TRUSS HEAD 10 32 3 8 LONG Z004173 15 BRACKET VENT PIPE Z096786 16 PORT STEAM INLET 141336 17 GASKET STEAM I...

Page 22: ...LONG Z096773 HOSE CAVITY DRAIN SANTOPRENE 1 1 2 ID 25 1 2 LONG 141456 HOSE CAVITY DRAIN SANTOPRENE 1 1 2 ID 35 LONG 141490 HOSE EXTENSION SANTOPRENE 1 1 2 ID 4 LONG 141455 NUT FLANGED 1 NPT Z099939 RE...

Page 23: ...R 139942 3 ASSEMBLY COVER TOP HY 6 143116 4 SCREW TRUSS HEAD 10 32 3 8 LONG Z004173 5 BRKT TOP RETAINER 123156 6 SCREW SLOTTED WASHER HEAD HEX CAP 8 32 3 8 LONG Z069789 7 WELDMENT LOWER FRONT PANEL 13...

Page 24: ...72108 9 LABEL FIELD WIRING HY 6E 100927 10 LABEL 208 VOLT Z008118D 10 LABEL 240 VOLT Z008118G 10 LABEL 480 VOLT Z008118J 11 TIMER STEAMER Z096826 12 LABEL L1 L2 L3 THREE PHASE Z008450M1 12 LABEL THREE...

Page 25: ...ER INSTALLATION Z099961 7 LABEL WARRANTIES VOID Z074816 8 LABEL PLUMBING CODE ADVISORY Z072118 9 LABEL LOCATION WATER VALVES 100985 LABLE DELIME HOSE BOTTOM Z090782 LABEL DELIME HOSE TOP Z090781 12 LA...

Page 26: ...LET 3 8 HOSE DUAL OUTLET 24V Z071235 2 VALVE WATER 3 4 INLET 3 8 HOSE SINGLE OUTLET 24V 100934 3 SCREW SLOTTED WASHER HEAD HEX CAP 8 32 3 8 LONG Z069789 4 LABEL UN TREATED WATER SUPPLY Z095652 5 LABEL...

Page 27: ...CASTER COMPONENTS Key Description Part 1 INSERT FOOT BULLET Z042505 2 INCERT FOOT FLANGED Z097615 3 INSERT CASTER 4 WHEEL NON LOCKING 140116 4 INSERT CASTER 4 WHEEL LOCKING 140115 KIT CASTER RESTRAIN...

Page 28: ...28 OM HY 6E Electrical Schematic...

Page 29: ...OM HY 6E 29 Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Page 30: ...REV G 03 16 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2016 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Reviews: