14
OM/SM-BPM-G
14
Connects to the braising pan by means
of flexible conduit. (Rear of Upper Control Box)
c) Undo and remove the retaining collar which
secures the On/Off switch to the outer surface of
the control cabinet.
d) Withdraw the On/Off switch from control
compartment.
e) Replace in reverse order.
3.8 Removal of Neons
(Turn gas and
electricity mains off)
a) Remove control panel lid and side panel as
described in Paragraph 3.3.1 and 3.3.2.
b) Disconnect the neons’ flying leads.
c) Undo and remove the retaining collar which
d) Remove the gasket between control box and panel.
secures the neon to the control cabinet.
e) Withdraw the neon from the control compartment.
f) Replace in reverse order.
3.9 Removal of Operating Thermostat
(Turn gas and electricity mains off)
To Replace
a) Remove upper control box panels as
described in Paragraph 3.3.3.
b) Remove thermostat from front panel.
c) Remove electrical leads from operating
thermostat.
d) Remove operating thermostat phial from the
underside of the pan, and remove retaining clips.
e) Remove the retaining clip which secures the
flexible conduit to the pan side.
f) Pull thermostat phial through the flexible conduit
(or cut if scrap).
g) Replace in reverse order.
To Calibrate
If calibration is required, use the following
procedures:
a) Fill the pan with unused oil to the indicated mark.
Place a thermocouple 25 mm below the oil
surface in the middle of the pan.
WARNING
DO NOT OVERFILL WITH OIL OR FIRE MAY
RESULT!
b) Remove the control knob and place a
screwdriver down the centre of the spindle.
c) Light the unit and allow the oil to heat.
d) Adjust the thermostat by turning the screwdriver
clockwise to decrease, and anti-clockwise to
increase temperature. Ensure that the
temperature settles at 190ºC (±5ºC). (
Note:
Thermostat may cycle seven or eight times
before oil temperature settles at 190ºC).
e) Replace control knob.
3.10 Removal of High Limit Thermostat
(Turn gas and electricity mains off)
This device is set to shut off the flow of gas to the
burners to prevent oil temperature from exceeding
230ºC. Manual intervention is required to reset the
control in the event of a lockout.
Fig. 12