background image

OM/SM-BPM-E CE          

Single Phase

1.  Installation

WARNING

THE BRAISING PAN MUST BE INSTALLED BY

PERSONNEL WHO ARE QUALIFIED TO WORK

WITH ELECTRICITY.  IMPROPER INSTALLATION

COULD RESULT IN PERSONAL INJURY OR

EQUIPMENT DAMAGE.

Internal wiring for the Braising Pan is supplied complete.

When you receive the unit, it is ready for connection.  A

wiring schematic is located inside the control box on the

right side of the pan, and in this manual.

Your pan was performance tested at the factory to

confirm that all controls and heating elements were

functioning correctly.

IMPORTANT

These appliances must be installed by a competent

person in conformity with the installation and servicing

instructions and national regulations in force at the

time. Particular attention must be paid to the following:

I.E.E. Regulations and Electrical Installations

Electricity at Work Regulations

Health and Safety at Work Act

Fire Precautions Act

Local and National Building Regulations

1.1   Installation is as follows:

Provide the proper electrical supply as

specified on the electrical information plate.

Comply with local codes and the National

Electrical Code ANSI/NFPA 70 - latest

edition.

Use appropriate sized copper wire,

rated at least 90ºC (194ºF).

Units are wired at the factory for three

phase or single phase (per order) operation

and should be connected as shown 

(See Fig. 1):

TERMINAL BLOCK

Set the unit in place and level it by turning the

adjustable feet. Crank the pan body to a

completely horizontal position. Check

levelness by placing a spirit level on the

bottom of the pan. The unit must be level to

avoid uneven cooking across the pan.

Make a

water tight

connection with the

incoming power line at the electrical service

entrance at the back of the control box.  A BX

connection is

NOT

recommended.

ELECTRICALLY

GROUND THE UNIT 

at the proper terminal.

WARNING

ELECTRICALLY GROUND THE BRAISING PAN 

AT THE TERMINAL PROVIDED.

Three Phase

1.1.1

1.1.2

1.1.3

Fig. 1    

Terminal Block

1.1.4

1.1.6

Conduit entry is at the control box on the rear left

side of the appliance.  Access to the terminals is

gained by removing the terminal block cover

shown in figure 2.

1.1.5

Fig. 2

1.2.   Water Supply 

- Not applicable to this appliance

         except for optional faucets.

Terminal 

Block 

Cover

Conduit Entry Opening

Summary of Contents for ECLIPSE BPM-30CE

Page 1: ...e can cause property damage injury or death Readtheinstallation operatingandmaintenanceinstructions thoroughly before installing or servicing this equipment NOTIFY CARRIER OF DAMAGE AT ONCE It is the...

Page 2: ...ITY BECOME VERY HOT AND WILL CAUSE BURNS IF TOUCHED ACCIDENTALLY UNLESS OTHERWISE STATED PARTS WHICH HAVE BEEN PROTECTED BY THE MANUFACTURER ARE NOT TO BE ADJUSTED BY THE INSTALLER CAUTION SHIPPING ST...

Page 3: ...ONTAINER IS FILLED OR TRANSFER IS COMPLETE 6 DO NOT OVER FILL CONTAINER AVOID DIRECT SKIN CONTACT WITH HOT CONTAINER AND ITS CONTENTS WARNING DO NOT HEAT AN EMPTY PAN FOR MORE THAN FIVE MINUTES AT A S...

Page 4: ...y New York New York 10018 National Fire Protection Association 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The National Electrical Code National Sanitation Foundation 3475 Plymouth Road A...

Page 5: ...ition Heatingelementsandotherelectricalcomponents are enclosed for safety The thermostat heating indicator light and tilting switch are contained in a compact control console which is mounted to the r...

Page 6: ...n the model number serial number and installation date of your unit and keep this information for future reference Space for these entries is provided at the top of the Service Log in this manual Cut...

Page 7: ...ecified on the electrical information plate Comply with local codes and the National Electrical Code ANSI NFPA 70 latest edition Use appropriate sized copper wire rated at least 90 C 194 F Units are w...

Page 8: ...1 W K 6 0 1 t l o V 0 3 2 p m A 61 1 p m A 6 4 e s a h P e l g n i S W K 14 1 W K 10 6 t l o V 0 0 4 p m A 20 4 p m A 15 4 e s a h P e e r h T 1 3 Electrical System Performance Cover Cover Handle Powe...

Page 9: ...hen the thermostat is turned off and that it comes on when it is switched back on Repeat 2 3 times c Remove all water from the pan and thoroughly dry the pan d Fill the pan with unused oil up to the m...

Page 10: ...er of cover See Fig 2 c Remove the side panel d Replace in reverse order a Remove the side panel per 3 2 1 above c Remove the two nuts holding the front edge of cover to the gearbox after side panel i...

Page 11: ...strip i Thread thermostat bulb and capillary through the h Remove water protection housing from thermostat shaft trunnion j Remove fiberglass sleeving from the thermostat k Replace in reverse order bu...

Page 12: ...ctrical cabinet top panel assembly and side panel as described in Paragraph 3 2 b Fill the pan with unused oil to the indicated mark 50mm maximum Place a thermocouple or thermometer 25 mm below the oi...

Page 13: ...ormer e Remove transformer f Replace in reverse order 3 10 Fuse Replacement a Remove electrical cabinet top panel assembly and 3 11 Removal of Heating Element s a Identify the heating element that nee...

Page 14: ...14 OM SM BPM E CE WIRING SCHEMATICS Model BPM 30E CE...

Page 15: ...OM SM BPM E CE 15 WIRING SCHEMATICS Model BPM 40E CE...

Page 16: ...at neon to come on c Safety Features A high limit safety thermostat which cuts off power to the heating elements if the operating thermostat fails i e should the temperature exceed operating limits A...

Page 17: ...ou put it down 4 7 Power Failure a If power to the unit is lost do not attempt to operate the appliance until the electricity has been restored b When the power comes on again follow the steps in Para...

Page 18: ...12 hours CAUTION KEEP WATER AND CLEANING SOLUTIONS OUT OF CONTROLS AND ELECTRICAL EQUIPMENT DO NOT SPRAY OR HOSE THE CONTROL BOX OR OTHER ELECTRICAL CONNECTIONS THEY ARE NOT WATER PROOF b To remove a...

Page 19: ...from the Zep Manufacturing Company j When the equipment needs to be sanitized use a sanitizing solution equivalent to one that supplies 100 parts per million available chlorine Get advice about the b...

Page 20: ...gs on the gear hosing until grease flows out of the bearings around trunion shaft Also add grease in the gear to cover arc that is in contact with the worm gear Clean up excess grease WARNING DISCONNE...

Page 21: ...g X Rapid clicking noise chattering User a For low voltage Auth Service Rep Only b Contactor for dirt or corrosion on the contacts c Transformer step down voltage X X Uneven cooking due to hot spots U...

Page 22: ...WITH BRAKE AND 2 W O BRAKE 146354 1 CASTER WITH BRAKE W O FOOT ADAPTER 146513 1 CASTER WITHOUT BRAKE W O FOOT ADAPTER NOT SHOWN 146515 2 FOOT ADAPTER 146516 3 FLANGED FOOT W O FOOT ADAPTER 146521 4 BU...

Page 23: ...MBLY 40 GALLON 160808 145480 144790 2 1 COUNTERBALANCE ASSEMBLY 30 GALLON 2 1 COUNTERBALANCE ASSEMBLY 40 GALLON 3 4 STUD WELD 1 4 20 X 1 1 4 012589 4 4 WASHER LOCK 3 8 005618 5 4 SCREW HEX HEAD CAP 3...

Page 24: ...A G 0 3 S P M A L C R E T A E H 5 1 3 4 4 8 2 1 0 N O L L A G 0 4 S P M A L C R E T A E H 8 1 3 8 6 9 2 1 0 B L U B T A T S O M R E H T P M A L C 1 4 2 5 8 2 1 0 N O L L A G 0 3 R E G N A H T I U D N...

Page 25: ...W E R C S 2 6 4 6 7 4 2 1 G N I R G N I N I A T E R 1 7 8 3 7 7 3 1 T E K C A R B T E C U A F 1 8 9 8 SCREW 1 4 20 x 3 8 TRUSS 125609 4 1 3 4 4 1 X O B K C O L B W O L L I P 1 0 1 9 8 9 2 0 0 K C O L...

Page 26: ...BPM E CE PARTS LIST Electrical Control Components 28 26 27 26 25 32 31 30 29 24 12 13 13 14 10 5 15 19 19 20 18 22 22 23 23 7 7 8 1 16 5 5 2 3 4 20 10 10 10 10 10 10 10 10 10 10 10 10 21 21 6 17 11 9...

Page 27: ...40 22 2 003122 SCREW ROUND HEAD 4 40 X 3 4 21 2 012940 NUT HEXAGON KEPS 1 4 20 20 2 005610 SCREW HEX HD 1 4 20 X 1 19 2 146989 CLAMP CABLE 3 8 18 1 143319 SWITCH TILT DPST 17 1 003490 BARRIER INSULATI...

Page 28: ...FITTING GREASE 90 NOT SHOWN 012195 15 1 BUSHING SNAP NOT SHOWN 000453 16 2 WASHER LOCK 005618 17 2 SCREW HEX HEAD CAP 005612 OM BPM E 23 Manual Tilt Assembly Parts List MANUAL TILT ASSEMBLY KEY QTY Pa...

Page 29: ...__________________ Serial No ___________________________ Location ____________________________ Date Purchased ______________________ Date Installed ________________________ Purchase Order No _________...

Page 30: ...__________________ Serial No ___________________________ Location ____________________________ Date Purchased ______________________ Date Installed ________________________ Purchase Order No _________...

Page 31: ...during the warranty period IV This warranty does not cover boiler maintenance calibration or periodic adjustments as specified in operating instructions or manuals and consumable parts such as scrape...

Page 32: ...1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 groen com PART NUMBER 153352 REV A 3 07...

Reviews: