OM-DEES        9

Operation

The operator controls kettle heating with the thermostat dial. The dial turns heating 

element power on or off and sets the kettle operating temperature.

A.   Controls

1.  Classic Control Models 

a. 

Lighted Power ON switch located on the control console.  Controls 

main power to the unit.

b.  The temperature knob, located on the control console, is used to set 

the kettle heat values between 1 and 10. 

c. 

Heating indicator light located on the control console, lights when the 

controller energizes the heating elements and will cycle on and off 

once the unit reaches set temperature.  If the unit is tilted, the heating 

elements will be disabled and the light will turn off until the unit is 

returned to the cooking position.

d.  A LOW WATER indicator light, located on the control console, 

illuminates when the jacket water falls below acceptable levels.  

When lit, the heating elements are disabled and will not function 

until the jacket water is refilled using the procedure on p. 16 of this 

manual. 

e. 

Crank tilt - a handle controls the worm and gear mechanism that 

smoothly tilts the kettle body and holds it in the desired position.

2.  Advanced Control Models

a. 

Lighted Power ON switch located on the control console.  Controls 

main power to the unit.

b.  The temperature knob, located on the control console, is used to set 

the kettle heat values between 1 and 10. The current setting will be 

reflected on the display.

c. 

Heating indicator light located on the control console, lights when the 

controller energizes the heating elements and will cycle on and off 

once the unit reaches set temperature.  If the unit is tilted, the heating 

elements will be disabled and the light will turn off until the unit is 

returned to the cooking position.

d.  A LOW WATER indicator light, located on the control console, 

illuminates when the jacket water falls below acceptable levels.  

When lit, the heating elements are disabled and will not function 

until the jacket water is refilled using the procedure on p. 16 of this 

manual. 

e. 

SET TnnP Mode - Allows power to the controller without the kettle 

heating; the kettle will heat once the LOW TEMP, MANUAL or HIGH 

TEMP button is selected.

f. 

LOW TEMP Button – Used to set operating temperature of the kettle 

at a preset low intensity (default = 2).  Can be pressed at any time 

during operation of the unit to change the set temperature to the 

preset value except when there is an active TIMER enabled.

g.  MANUAL Mode button – Enables the user modify the desired cooking 

temperature of the kettle (between 1 and 10) using the temperature 

knob and display (default = 4).  The operator will press the MANUAL 

button and set the desired temperature using the temperature knob 

and display.  Once the desired temperature is reached, the user may 

either press the MANUAL button again or wait 5 seconds and the set 

temperature will be accepted by the controller and locked in.  After 

the set temperature is accepted, it may be changed at any time by 

pressing the MANUAL button and resetting the temperature using the 

CAUTION 

DO NOT OVERFILL THE KETTLE WHEN 

COOKING, HOLDING OR CLEANING. KEEP 

LIQUIDS AT LEAST 2-3” (5-8 cm) BELOW 

THE KETTLE BODY RIM TO ALLOW 

CLEARANCE FOR STIRRING, BOILING

PRODUCT AND SAFE TRANSFER.

Classic Control

Advanced Control

Summary of Contents for DEES-40

Page 1: ...ility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed dam age Unified Brands suggests that if you are suspicious of da...

Page 2: ...OOKING HOLDING OR CLEANING KEEP LIQUIDS A MINIMUM OF 2 3 5 8 cm BELOW THE KETTLE BODY RIM TO ALLOW CLEARANCE FOR STIRRING BOILING AND SAFE PRODUCT TRANSFER WARNING TAKE SPECIAL CARE TO AVOID CONTACT W...

Page 3: ...T NEVER USE A HIGH PRESSURE HOSE TO CLEAN KETTLE SURFACES CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOULD BE TAKEN WEAR RUBBER GLOVES GOGGLES OR FAC...

Page 4: ...DE SALES CENTER ECOLAB Inc 370 Wabasha St Pau Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The National El...

Page 5: ...irless operation of the steam jacket permits uniform efficient heating at temperatures as low as 150 F and as high as 298 F In addition to the electronic temperature control the unit has a tilt cut of...

Page 6: ...oroughly inspect the unit for concealed damage Report any shipping damage or incorrect shipments to the delivery agent Write down the model number serial number and installation date and retain this i...

Page 7: ...ce at the rear of the support housing with one inch conduit making a watertight connection with the incoming lines Observe local codes and or the National Electrical Code in compliance with ANSI NFPA...

Page 8: ...of this manual begin heating the water at the highest thermostat setting The heating indicator light should come on immediately and heating should continue until the water boils 7 To shut down the uni...

Page 9: ...ng elements and will cycle on and off once the unit reaches set temperature If the unit is tilted the heating elements will be disabled and the light will turn off until the unit is returned to the co...

Page 10: ...d within 20 degrees of set point during pre heat and when a higher set temperature is selected k Crank tilt a handle controls the worm and gear mechanism that smoothly tilts the kettle body and holds...

Page 11: ...apron When putting a lift off cover on the kettle position it on top of kettle rim with its flat edge facing the pouring lip When removing the lift off cover 1 Firmly grasp the handle 2 Lift rear edge...

Page 12: ...uct lift straight up ensuring basket bottoms clear the kettle rim and pouring lip Wear protective oven mitts and protective apron 6 Allow hot water to fully drain from product before moving basket awa...

Page 13: ...erature This is why the heating indicator light cycles on and off during normal operation Every time the kettle is tilted the tilt cut off switch interrupts the power supply to the heaters so that the...

Page 14: ...the marks on the gauge glass If the level is low see Jacket Filling and Water Treatment on page 16 3 Carefully test the pressure relief valve at least twice each month With the kettle operating at 15...

Page 15: ...e every six months 8 Use a 2 grade LGI lithium grease to add grease through Zerk fittings on gear housing until it flows out of the bearings around the trunnion shaft 9 Place liberal amounts of grease...

Page 16: ...t or if the vacuum is leaking down contact an authorized service agency to correct the problem C Jacket Filling and Water Treatment The jacket was charged at the factory with the proper amount of trea...

Page 17: ...up 5 Stir the water continuously while you slowly add water treatment com pound until the water reaches a pH between 10 5 and 11 5 Judge the pH by frequently comparing the test strip color with the co...

Page 18: ...clean soiled external and internal surfaces Remember to check the sides of the unit and control housing f To remove stuck materials use a brush sponge cloth plastic or rub ber scraper or plastic wool...

Page 19: ...horoughly i It is recommended that each piece of equipment be sanitized just before use j If there is difficulty removing mineral deposits or a film left by hard water or food residues clean the kettl...

Page 20: ...ow water cutoff X Kettle will not heat but heating indicator comes on Authorized Service Rep Only a Temperature control calibration and offsets X b Heater elements with ohmmeter for ground short or op...

Page 21: ...OM DEES 21 Parts List For Classic Advanced Control Models...

Page 22: ...22 OM DEES Parts List For Classic Advanced Control Models...

Page 23: ...TER LEVEL BOARD 122192 19 PRESSURE SWITCH 096963 20 CONTROL CLASSIC CONTROL ADVANCED 174843 174837 21 WATER LEVEL PROBE 070178 22 ELEMENT 208V 9 95KW ELEMENT 240V 8KW ELEMENT 480V 8KW 005977 005974 00...

Page 24: ...24 OM DEES Wiring Diagram For Classic Control Models...

Page 25: ...OM DEES 25 Wiring Diagram For Advanced Control Models...

Page 26: ...26 OM DEES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Service Performed Performed By...

Page 27: ......

Page 28: ...REV C 07 17 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2017 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Reviews: