Groen DEES-40 Operator'S Manual Download Page 16

16 OM-DEES

WARNING 

TO AVOID INJURY, READ AND FOLLOW ALL 

PRECAUTIONS STATED ON THE LABEL OF 

THE WATER TREATMENT COMPOUND.

Maintenance

B.  Jacket Vacuum/Removing Air from Jacket

When the kettle is cold, a positive pressure reading on the pressure/vacuum

gauge or a reading near zero indicates that there is air in the jacket. Air in the

jacket acts as an insulator, and slows kettle heating.

To remove air:

1.  Start the unit. (Be sure there is water or product in the kettle when 

 heating).

2.  When the pressure/vacuum gauge reaches a positive pressure reading of 

five PSI, release the trapped air and steam by pulling up the safety valve 

ring for about five seconds. Repeat this step three or four times. Then let 

the pull ring snap back into the closed position.

3.  If there is little discharge (mostly air), and the pressure gauge drops back 

to zero PSI, allow the pressure to build back to five PSI and repeat the 

procedure.

4.  Once steam has been vented from the jacket as described in b, above, 

remove the hot water from the kettle and replace it with cold. This will 

condense steam in the kettle jacket, and the pressure gauge should 

show a reading of 20 to 30 inches mercury (Hg) below zero. If it does not, 

or if the vacuum is leaking down, contact an authorized service agency to 

correct the problem.

C.  Jacket Filling and Water Treatment

The jacket was charged at the factory with the proper amount of treated water.

You may need to restore this water, either because it was lost as venting

steam or by draining. If you are replacing water lost as steam, use distilled

water. If you are replacing treated water that ran out of the jacket, prepare

more treated water as directed in “Water Treatment Procedure,” below.

1.  Allow the kettle to cool completely. The procedure will be easier with the 

kettle under vacuum (pressure gauge reading below zero).

2.  Allow the kettle to cool completely. Remove the pipe plug from the jacket 

fill assembly. Pour in the distilled or treated water. Using a funnel will 

help you in this process. Hold the pressure relief valve open while you 

pour, to let air escape from the jacket. Continue adding water until the 

water level rises to the center of the round sight glass.

3.  Position a funnel in the opening and fill it with properly treated water.

4.  Air that gets into the jacket during the filling operation must be removed, 

because it will make heating less efficient. Follow the procedure in 

Jacket Vacuum/Removing Air From Jacket above, to restore a negative 

pressure reading.

Pressure
Gauge

Pipe
Plug

Check 
Valve

Safety 
Valve

Test the safety valve 

at least twice monthly.

Summary of Contents for DEES-40

Page 1: ...ility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed dam age Unified Brands suggests that if you are suspicious of da...

Page 2: ...OOKING HOLDING OR CLEANING KEEP LIQUIDS A MINIMUM OF 2 3 5 8 cm BELOW THE KETTLE BODY RIM TO ALLOW CLEARANCE FOR STIRRING BOILING AND SAFE PRODUCT TRANSFER WARNING TAKE SPECIAL CARE TO AVOID CONTACT W...

Page 3: ...T NEVER USE A HIGH PRESSURE HOSE TO CLEAN KETTLE SURFACES CAUTION MOST CLEANERS ARE HARMFUL TO THE SKIN EYES MUCOUS MEMBRANES AND CLOTHING PRECAUTIONS SHOULD BE TAKEN WEAR RUBBER GLOVES GOGGLES OR FAC...

Page 4: ...DE SALES CENTER ECOLAB Inc 370 Wabasha St Pau Minnesota 55102 800 352 5326 or 612 293 2233 NATIONAL FIRE PROTECTION ASSOCIATION 60 Battery March Park Quincy Massachusetts 02269 NFPA 70 The National El...

Page 5: ...irless operation of the steam jacket permits uniform efficient heating at temperatures as low as 150 F and as high as 298 F In addition to the electronic temperature control the unit has a tilt cut of...

Page 6: ...oroughly inspect the unit for concealed damage Report any shipping damage or incorrect shipments to the delivery agent Write down the model number serial number and installation date and retain this i...

Page 7: ...ce at the rear of the support housing with one inch conduit making a watertight connection with the incoming lines Observe local codes and or the National Electrical Code in compliance with ANSI NFPA...

Page 8: ...of this manual begin heating the water at the highest thermostat setting The heating indicator light should come on immediately and heating should continue until the water boils 7 To shut down the uni...

Page 9: ...ng elements and will cycle on and off once the unit reaches set temperature If the unit is tilted the heating elements will be disabled and the light will turn off until the unit is returned to the co...

Page 10: ...d within 20 degrees of set point during pre heat and when a higher set temperature is selected k Crank tilt a handle controls the worm and gear mechanism that smoothly tilts the kettle body and holds...

Page 11: ...apron When putting a lift off cover on the kettle position it on top of kettle rim with its flat edge facing the pouring lip When removing the lift off cover 1 Firmly grasp the handle 2 Lift rear edge...

Page 12: ...uct lift straight up ensuring basket bottoms clear the kettle rim and pouring lip Wear protective oven mitts and protective apron 6 Allow hot water to fully drain from product before moving basket awa...

Page 13: ...erature This is why the heating indicator light cycles on and off during normal operation Every time the kettle is tilted the tilt cut off switch interrupts the power supply to the heaters so that the...

Page 14: ...the marks on the gauge glass If the level is low see Jacket Filling and Water Treatment on page 16 3 Carefully test the pressure relief valve at least twice each month With the kettle operating at 15...

Page 15: ...e every six months 8 Use a 2 grade LGI lithium grease to add grease through Zerk fittings on gear housing until it flows out of the bearings around the trunnion shaft 9 Place liberal amounts of grease...

Page 16: ...t or if the vacuum is leaking down contact an authorized service agency to correct the problem C Jacket Filling and Water Treatment The jacket was charged at the factory with the proper amount of trea...

Page 17: ...up 5 Stir the water continuously while you slowly add water treatment com pound until the water reaches a pH between 10 5 and 11 5 Judge the pH by frequently comparing the test strip color with the co...

Page 18: ...clean soiled external and internal surfaces Remember to check the sides of the unit and control housing f To remove stuck materials use a brush sponge cloth plastic or rub ber scraper or plastic wool...

Page 19: ...horoughly i It is recommended that each piece of equipment be sanitized just before use j If there is difficulty removing mineral deposits or a film left by hard water or food residues clean the kettl...

Page 20: ...ow water cutoff X Kettle will not heat but heating indicator comes on Authorized Service Rep Only a Temperature control calibration and offsets X b Heater elements with ohmmeter for ground short or op...

Page 21: ...OM DEES 21 Parts List For Classic Advanced Control Models...

Page 22: ...22 OM DEES Parts List For Classic Advanced Control Models...

Page 23: ...TER LEVEL BOARD 122192 19 PRESSURE SWITCH 096963 20 CONTROL CLASSIC CONTROL ADVANCED 174843 174837 21 WATER LEVEL PROBE 070178 22 ELEMENT 208V 9 95KW ELEMENT 240V 8KW ELEMENT 480V 8KW 005977 005974 00...

Page 24: ...24 OM DEES Wiring Diagram For Classic Control Models...

Page 25: ...OM DEES 25 Wiring Diagram For Advanced Control Models...

Page 26: ...26 OM DEES Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Service Performed Performed By...

Page 27: ......

Page 28: ...REV C 07 17 1055 Mendell Davis Drive Jackson MS 39272 888 994 7636 601 372 3903 Fax 888 864 7636 unifiedbrands net 2017 Unified Brands All Rights Reserved Unified Brands is a wholly owned subsidiary o...

Reviews: