OM-DEES(T)-40(C,A,C2T™) Domestic

5.  HIGH TEMP and LOW TEMP presets cannot be used to change the 

setpoint once a TIMER has started.

j.  READY alarm – The control will sound 3 beeps when the unit has reached 

within 20 degrees of set point during pre-heat and when a higher set 
temperature is selected.

k.  Crank tilt - a handle controls the worm and gear mechanism that smoothly 

tilts the kettle body and holds it in the desired position.

3.  Cook2Temp™ Control (-C2T™) Models

a.  Lighted Power ON switch located on the control console. Controls main 

power to the unit.

b.  Heating indicator light located on the control console, lights when the 

controller energizes the heating elements and will cycle on and off once 
the unit reaches set temperature. If the unit is tilted, the call for heat will 
be interrupted and the light will turn off until the unit is returned to the 
cooking position.

c.  Low Water indicator light, located on the control console, lights when 

the jacket water falls below the acceptable levels. When lit, the heating 
elements are disabled and will not function until the jacket water is refilled 
using the procedure in the operator manual.

d.  Set Mode – Allows power to the controller without the kettle heating, the 

kettle will heat once the LOW TEMP, MANAUAL or HIGH TEMP button is 
selected.

e.  LOW TEMP Button – Used to set a unit temperature of the kettle at a preset 

low temperature (default = 175°F). Can be pressed at any time during 
operation of the unit to change the unit temperature to the preset value 
except when there is an active TIMER or an active Cook2Temp.

f.  MANUAL Button – Enables the user to modify the unit temperature of 

the kettle (between 100°F and 287°F) using the temperature knob and 
display (default = 183°F). The operator will press the MANUAL button and 
then select the desired unit temperature using the temperature knob and 
display. Once the desired unit temperature is shown on the display, the 
user may either press the MANUAL button again or wait 5 seconds and 
the selected temperature will be accepted by the controller and locked in. 
After the selected temperature is accepted it may be changed at any time 
by pressing the MANUAL button and resetting the temperature using the 
same process as above except when there is an active AUTO Cook2Temp.

g.  HIGH TEMP Button – Used to set unit temperature of the kettle at a preset 

high temperature (default = 287°F). Can be pressed at any time during 
operation of the unit to change the unit temperature to the preset value 
except when there is an active TIMER or an active Cook2Temp.

h.  TIMER Button – Once the appropriate unit temperature is selected using 

the LOW TEMP, MANUAL or HIGH TEMP buttons, a countdown timer can be 
set to remind the user when the cooking process is completed.
1.  Range – 1 minute to 10 hours.
2.  When the timer expires:

a.  The unit temperature will automatically change to the LOW TEMP 

setting and will continue at this setting until the user changes the 
temperature via MANUAL or HIGH TEMP buttons.

b.  An audible alarm will notify the user that attention is required, 

the alarm will continue to sound until the user presses the TIMER 
button.

3.  An active timer can be cancelled by pressing and holding the TIMER 

button for 5 seconds.

4.  Unit temperature can be changed during an active timer by pressing 

the MANUAL button and adjusting the unit temperature using the 
temperature knob and display.

5.  LOW TEMP and HIGH TEMP presets cannot be used to change the unit 

temperature once a TIMER has been enabled.

6.  AUTO C2T and MANUAL C2T cannot be used once a timer has been 

enabled. The timer must first be cancelled and then AUTO C2T or 
MANUAL C2T can be enabled.

i.  Ready alarm – The control will sound 3 beeps when the unit has reached 

within 20 degrees of set point during pre-heat and when a higher unit 
temperature is selected.

j.  AUTO C2T Button – Enables the user to select a set product temperature 

(between 100°F and 230°F) using the temperature knob and display. 
The operator will press the AUTO C2T button and then select the set 
product temperature using the temperature knob and display. Once the 
set product temperature is shown on the display, the user may either 
press the AUTO C2T button again or wait 5 seconds and the selected 
temperature will be accepted by the controller and locked in. The unit 
temperature is automatically set 100°F above the set product temperature 
and cannot be changed at any time during an active AUTO C2T. After the 
set product temperature is accepted it may be changed at any time by first 
cancelling AUTO C2T and then using the same process as above to reset 
the temperature.
1.  After the set product temperature is accepted by the controller and 

locked in. The unit will begin to heat and the display will scroll the 
actual product temperature followed by the set product temperature. 
This display will continue until the cook process has completed.

2.  An active AUTO C2T can be cancelled by pressing and holding the 

AUTO C2T button for 5 seconds and the unit will then return to Set 
Mode.

3.  LOW TEMP, MANUAL or HIGH TEMP presets cannot be used to change 

the unit temperature once there is an active AUTO C2T. The unit 
temperature is automatically set by the controller.

4.  Once the set product temperature has been reached and held for 20 

seconds consecutively the unit will automatically enable Hold Mode.

k.  MANUAL C2T Button – Enables the user to select a set product 

temperature (between 100°F and 230°F) using the temperature knob and 
display. The operator will press the MANUAL C2T button and then select 
the set product temperature using the temperature knob and display. 
Once the set product temperature is shown on the display, the user may 
either press the MANUAL C2T button again or wait 5 seconds and the 
selected temperature will be accepted by the controller and locked in.  
Once the set product temperature has been accepted the user will be 
prompted to select a unit temperature via the MANUAL button. Once 
the set unit temperature is shown on the display, the user may either 
press the MANUAL C2T button again or wait 5 seconds and the selected 
temperature will be accepted by the controller and locked in. After the 
set product temperature and unit temperature are accepted the product 
temperature may be changed at any time by first cancelling MANUAL C2T 
and then using the same process as above to reset the temperature.
1.  After the set product temperature and unit temperature are accepted 

by the controller and locked in. The unit will begin to heat and the 
display will scroll the actual product temperature followed by the set 
product temperature. This display will continue until the cook process 
has completed.

2.  An active MANUAL C2T can be cancelled by pressing and holding the 

MANUAL C2T button for 5 seconds and the unit will then return to Set 
Mode.

3.  Unit temperature can be changed during an active MANUAL C2T by 

pressing the MANUAL button and adjusting the unit temperature using 
the temperature knob and display.

4.  Once the set product temperature has been reached and held for 20 

seconds consecutively the unit will automatically enable Hold Mode.

l.  Hold Mode – Allows the unit to be controlled by the set product temperature 

and core probe.
1.  Hold Mode is automatically enabled once a set product temperature 

has been reached and held for 20 seconds consecutively. 

Summary of Contents for DEE/4-20 A

Page 1: ...tle finish is 180 emery grit on the inside and bright semi deluxe on the outside The kettle can be tilted with a hand crank to pour out its contents Stainless steel panels enclose the controls and the...

Page 2: ...IN AND MINIMIZE PRODUCT SPLASHING 2 PLACE CONTAINER ON STABLE FLAT SURFACE AS CLOSE TO KETTLE AS POSSIBLE 3 DO NOT OVER FILL CONTAINER AVOID DIRECT SKIN CONTACT WITH HOT CONTAINER AND ITS CONTENTS CAU...

Page 3: ...e with ANSI NFPA 70 current edition 6 The equipment is shipped ready for three phase operation Refer to the wiring diagram for single phase operation Kit 170960 is available for single phase wiring an...

Page 4: ...hted Power ON switch located on the control console Controls main power to the unit b The temperature knob located on the control console is used to set the kettle heat values between 1 0 and 10 0 The...

Page 5: ...led The timer must first be cancelled and then AUTO C2T or MANUAL C2T can be enabled i Ready alarm The control will sound 3 beeps when the unit has reached within 20 degrees of set point during pre he...

Page 6: ...he cook process or Hold Mode will continue e While the core probe is not in use ensure the sealing cap is properly protecting the panel mount connector Failure to properly use the sealing cap could re...

Page 7: ...exterior at least once every 12 hours WARNING AVOID ANY DIRECT CONTACT WITH HOT SURFACES DIRECT SKIN CONTACT COULD RESULT IN SEVERE BURNS b Scrape and flush out food residues Be careful not to scratc...

Page 8: ...least twice each month With the kettle operating at 15 psi 105 kPa pull the test lever and let it snap back to its closed position If there is little discharge mostly air and the pressure gauge drops...

Page 9: ...treatment compound used These amounts may be used again if the same water sources and compound are used in the future However it is best to check the pH each time treated water is prepared SEQUENCE O...

Page 10: ...ohmmeter for ground short or open element If element is defective call service X Kettle continues heating after it reaches the desired temperature User a Control knob setting Authorized Service Rep On...

Page 11: ...11 OM DEES T 40 C A C2T Domestic Parts List...

Page 12: ...12 OM DEES T 40 C A C2T Domestic Parts List...

Page 13: ...24 27 WELDMENT FRAME STAND 20 WELDMENT FRAME STAND 40 60 174805 174802 28 WELDMENT CLADDING STAND 20 174806 29 WELDMENT PEDESTAL 20 175379 30 WELDMENT CLADDING PEDESTAL 20 175378 KEY DESCRIPTION PART...

Page 14: ...14 OM DEES T 40 C A C2T Domestic Wiring Diagram For Classic Control Models...

Page 15: ...15 OM DEES T 40 C A C2T Domestic Wiring Diagram For Advanced Cook2Temp Control Models...

Page 16: ...16 OM DEES T 40 C A C2T Domestic Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Reviews: