7.  To shut down the unit, turn the power switch to “OFF”.
If the unit functions as described above, it is ready for use. If the unit does not 
function as intended, first recheck power supply connections and, if necessary, 
contact your local Certified Service Agency.

OPERATION

WARNING:   WHEN TILTING KETTLE:
 

1) WEAR PROTECTIVE OVEN MITT AND PROTECTIVE APRON.

 

2) USE DEEP CONTAINER TO CONTAIN AND MINIMIZE PRODUCT SPLASHING.

 

3) PLACE CONTAINER ON STABLE, FLAT SURFACE, AS CLOSE TO KETTLE AS 

POSSIBLE.

 

4) STAND TO RIGHT OF KETTLE WHILE POURING — NOT DIRECTLY IN POUR PATH 

OF HOT CONTENTS.

 

5) POUR SLOWLY, MAINTAINING CONTROL OF KETTLE, AND RETURN KETTLE 

BODY TO UPRIGHT POSITION AFTER CONTAINER IS FILLED OR TRANSFER IS 

COMPLETE.

 

6) DO NOT OVERFILL CONTAINER. AVOID SKIN CONTACT WITH HOT CONTAINER 

AND ITS CONTENTS.

WARNING:  AVOID ALL DIRECT CONTACT WITH HOT SURFACES AND HOT FOOD OR WATER IN 

THE KETTLE. DIRECT CONTACT COULD RESULT IN SEVERE BURNS.

CAUTION:  DO NOT OVERFILL THE KETTLE WHEN COOKING, HOLDING OR CLEANING. 

KEEP LIQUIDS AT LEAST 2-3” (5-8 CM) BELOW THE KETTLE RIM TO ALLOW 

CLEARANCE FOR STIRRING, BOILING AND SAFE PRODUCT TRANSFER.

WARNING:  AVOID ALL DIRECT CONTACT WITH  HOT FOOD OR WATER IN THE KETTLE. 

DIRECT CONTACT COULD RESULT IN  SEVERE BURNS.

CAUTION:  HEATING AN EMPTY KETTLE MAY CAUSE  THE RELEASE OF STEAM FROM THE 

PRESSURE RELIEF VALVE.

CAUTION:  DO NOT TILT KETTLE BODY WITH COVER OR BASKET INSERT IN PLACE. COVER 

MAY SLIDE OFF, CAUSING INJURY TO OPERATOR.

CAUTION:  ANY POTENTIAL USER OF THE EQUIPMENT MUST BE TRAINED IN SAFE AND 

CORRECT OPERATING PROCEDURES.

WARNING:  KEEP AREA AROUND KETTLE FREE AND CLEAR OF ALL COMBUSTIBLE 

MATERIALS. DO NOT ATTEMPT TO LIGHT ANY BURNER WITH A FLAME.

3

.

0

Classic Control

Advanced Control

Cook2Temp Control

CONTROLS
1.  Classic Control (-C) Models

a.   Lighted Power ON switch located on the control console.  Controls main 

power to the unit.

b.  The temperature knob, located on the control console, is used to set the 

kettle heat values between 1 and 10. 

c.  Heating indicator light located on the control console, lights when the 

controller energizes the heating elements and will cycle on and off once 
the unit reaches set temperature.  If the unit is tilted, the heating elements 

will be disabled and the light will turn off until the unit is returned to the 
cooking position.

d.  A LOW WATER indicator light, located on the control console, illuminates 

when the jacket water falls below acceptable levels.  When lit, the heating 
elements are disabled and will not function until the jacket water is refilled 
using the procedure in this manual. 

e.  Crank tilt - a handle controls the worm and gear mechanism that smoothly 

tilts the kettle body and holds it in the desired position.

2.

 

Advanced Control (-A) Models

a.  Lighted Power ON switch located on the control console.  Controls main 

power to the unit.

b.  The temperature knob, located on the control console, is used to set 

the kettle heat values between 1.0 and 10.0. The current setting will be 
reflected on the display.

c.  Heating indicator light located on the control console, lights when the 

controller energizes the heating elements and will cycle on and off once 
the unit reaches set temperature.  If the unit is tilted, the heating elements 
will be disabled and the light will turn off until the unit is returned to the 
cooking position.

d.  A LOW WATER indicator light, located on the control console, illuminates 

when the jacket water falls below acceptable levels.  When lit, the heating 
elements are disabled and will not function until the jacket water is refilled 
using the procedure in this manual. 

e.  SET TnnP Mode - Allows power to the controller without the kettle heating; 

the kettle will heat once the LOW TEMP, MANUAL or HIGH TEMP button is 
selected.

f.  LOW TEMP Button – Used to set operating temperature of the kettle at a 

preset low intensity (default = 2.0).  Can be pressed at any time during 
operation of the unit to change the set temperature to the preset value 
except when there is an active TIMER enabled.

g.  MANUAL Mode button – Enables the user modify the desired cooking 

temperature of the kettle (between 1.0 and 10.0) using the temperature 
knob and display (default = 5.0).  The operator will press the MANUAL 
button and set the desired temperature using the temperature knob 
and display.  Once the desired temperature is reached, the user may 
either press the MANUAL button again or wait 5 seconds and the set 
temperature will be accepted by the controller and locked in.  After the set 
temperature is accepted, it may be changed at any time by pressing the 
MANUAL button and resetting the temperature using the same process 
above.

h.  HIGH TEMP button – Used to set operating temperature of the kettle at a 

preset high intensity (default = 7.0).  Can be pressed at any time during 
operation of the unit to change the set temperature to the preset value 
except when there is an active TIMER enabled.

i.  TIMER button - once the appropriate set temperature is selected using the 

HIGH TEMP, MANUAL or LOW TEMP buttons; a countdown timer can be set 
to remind the user when the cooking process is completed.
1.  Range – 1 minute to 10 hours
2.  When the timer expires: 

a.  the set temperature will automatically change to the LOW TEMP 

setting and will continue at this setting until the user changes the 
temperature via MANUAL or HIGH TEMP buttons

b.  An audible alarm will notify the user that attention is required, 

the alarm will continue to sound until the user presses the TIMER 
button.   

3.  An active timer can be cancelled by pressing and holding the TIMER 

button for 5 secs.

4.  Set temp can be changed during an active timer by pressing the 

MANUAL button and adjusting the set temp using the Temperature 
knob and display.

Summary of Contents for DEE/4-20 A

Page 1: ...tle finish is 180 emery grit on the inside and bright semi deluxe on the outside The kettle can be tilted with a hand crank to pour out its contents Stainless steel panels enclose the controls and the...

Page 2: ...IN AND MINIMIZE PRODUCT SPLASHING 2 PLACE CONTAINER ON STABLE FLAT SURFACE AS CLOSE TO KETTLE AS POSSIBLE 3 DO NOT OVER FILL CONTAINER AVOID DIRECT SKIN CONTACT WITH HOT CONTAINER AND ITS CONTENTS CAU...

Page 3: ...e with ANSI NFPA 70 current edition 6 The equipment is shipped ready for three phase operation Refer to the wiring diagram for single phase operation Kit 170960 is available for single phase wiring an...

Page 4: ...hted Power ON switch located on the control console Controls main power to the unit b The temperature knob located on the control console is used to set the kettle heat values between 1 0 and 10 0 The...

Page 5: ...led The timer must first be cancelled and then AUTO C2T or MANUAL C2T can be enabled i Ready alarm The control will sound 3 beeps when the unit has reached within 20 degrees of set point during pre he...

Page 6: ...he cook process or Hold Mode will continue e While the core probe is not in use ensure the sealing cap is properly protecting the panel mount connector Failure to properly use the sealing cap could re...

Page 7: ...exterior at least once every 12 hours WARNING AVOID ANY DIRECT CONTACT WITH HOT SURFACES DIRECT SKIN CONTACT COULD RESULT IN SEVERE BURNS b Scrape and flush out food residues Be careful not to scratc...

Page 8: ...least twice each month With the kettle operating at 15 psi 105 kPa pull the test lever and let it snap back to its closed position If there is little discharge mostly air and the pressure gauge drops...

Page 9: ...treatment compound used These amounts may be used again if the same water sources and compound are used in the future However it is best to check the pH each time treated water is prepared SEQUENCE O...

Page 10: ...ohmmeter for ground short or open element If element is defective call service X Kettle continues heating after it reaches the desired temperature User a Control knob setting Authorized Service Rep On...

Page 11: ...11 OM DEES T 40 C A C2T Domestic Parts List...

Page 12: ...12 OM DEES T 40 C A C2T Domestic Parts List...

Page 13: ...24 27 WELDMENT FRAME STAND 20 WELDMENT FRAME STAND 40 60 174805 174802 28 WELDMENT CLADDING STAND 20 174806 29 WELDMENT PEDESTAL 20 175379 30 WELDMENT CLADDING PEDESTAL 20 175378 KEY DESCRIPTION PART...

Page 14: ...14 OM DEES T 40 C A C2T Domestic Wiring Diagram For Classic Control Models...

Page 15: ...15 OM DEES T 40 C A C2T Domestic Wiring Diagram For Advanced Cook2Temp Control Models...

Page 16: ...16 OM DEES T 40 C A C2T Domestic Service Log Model No Purchased From Serial No Location Date Purchased Date Installed Purchase Order No For Service Call Date Maintenance Performed Performed By...

Reviews: