background image

-2-

T26691-92  (Mfd. 10/14)

Cleaning/Maintenance

1.  DISCONNECT MACHINE FROM POWER!

2.  Use  eraser,  dry  cloth,  or  finger  to  remove 

residue from Teflon strip and rubber strip on 
arm. Do not use solvents.

3.  Install new Teflon strips and heating element. 

Place  element  between  strips,  then  reinstall 
metal plates. 

Troubleshooting

• 

If sealer creates a partial seal, select a higher 
dial setting to increase heating time.

• 

If sealer melts through bag, or if bag sticks to 
Teflon strip, select a lower dial setting.

• 

If bag sticks to rubber strip on arm, hold arm 
down  longer  after  red  light  switches  off  to 
increase cooling time.

If you need help with your new heat sealer, call 
our Tech Support at: (570) 546-9663.

3.  Open arm, place shortest width of bag across 

Teflon strip, and press arm down. Red indica-
tor light will illuminate.

 

Note: Sealer will not turn ON until you press 
arm down.

4.  After red light turns off, wait for seal to cool, 

then raise arm, and remove bag.

5.  Check seal. 

— If sealer leaves a 2-3mm wide band across 

bag, dial setting is correct. 

—If sealer does not leave an evenly melted 

band across bag, see 

Troubleshooting.

Electrical Schematic

FIgure 5. Model T26691-92 electrical schematic. 

2.  Remove front cover and push forward on ter-

minal  assembly  to  release  heating  element  
(see 

Figure 4). 

Service

If the Teflon strips become torn, replace them and 
the heating element. 

To replace Teflon strips and heating element:

1.  DISCONNECT MACHINE FROM POWER!

Figure 4. Components that must be removed 

when replacing Teflon strips or heating element.

Teflon 

Strips

Metal 

Plates

Heating 

Element

Front 

Cover

Reviews: