Model H8226 5 Gallon Automatic Mixing Paint Tank
-10
-
Troubleshooting
Symptom
Possible Cause
Solution
Air escaping from
port on regulating
cap.
1. Broken or damaged dia-
phragm in tank regulator.
1. Replace tank regulator.
Pressure dropping
slowly on regulator.
1. Dirty or worn valve seat in
regulator.
2. Loose air fittings leaking air.
1. Replace tank regulator.
2. Tighten loose air fittings or
remove and re-install with
new Teflon tape.
Fluid or air leak at
lid gasket.
1. Defective lid gasket.
2. Wing screw loose.
3. Dirt or foreign object between
gasket and rim.
1. Replace lid gasket.
2. Tighten wing screws.
3. Clean rim and gasket.
Paint tends to settle
rapidly in tank.
1. Paint not mixed or thinned suf-
ficiently.
1. Mix or thin paint according
to manufacturer's instruc-
tions.
Gauge not register-
ing air pressure.
1. Air pressure turned
OFF
.
2. Defective pressure gauge.
1. Turn air pressure
ON
.
2. Replace pressure gauge.
Safety valve pop-
ping off.
1. Tank pressure too high.
2. Defective safety valve.
1. Reduce tank pressure to
20-30 PSI (See
Page 8
).
2. Replace safety valve.