background image

Maintenance

Keep  the  hydraulic  rams  clean  and  free  of  any 
dust,  dirt,  or  foreign  debris.  Abrasive  material 
stuck  to  the  ram  can  damage  the  hydraulic  seal 
when  the  ram  is  retracted  back  into  the  jack. 
Regularly  wipe  the  hydraulic  rams  clean  with  a 
lightly oiled rag.

The Model H8095 will require hydraulic fluid after 
long-term  use.  This  will  be  noticeable  if  the  jack 
will not reach its maximum height when pumped.
Only use a high quality hydraulic fluid.

To add hydraulic fluid:

1.

  Completely lower the jack.

2.

  Remove the fill plug shown in 

Figure 2.

Figure 2.

 Fill plug.

3. 

Add fluid until it reaches the top of the fill plug 
hole.

4.

  Replace the fill plug.

5.

  Test  the  operation  of  the  jack  by  pumping 

it up to the maximum height and applying a 
load to the saddle. The jack should hold the 
weight of the load without a sinking or spongy 
feeling.

—If  the  jack  did  not  perform  properly,  then 

air  may  need  to  be  bled  from  the  pump 
system.

Fill Plug

Bleeding the Air

If the jack becomes spongy or will not rise when 
pumped, then air bubbles may be in the hydraulic 
system.

To remove the air bubbles:

1.

  Remove the fill plug.

2.

  Rotate  the  pump  handle  counterclockwise 

one full turn.

3.

  Pump the handle quickly ten times to purge 

the air from the system.

4.

  Replace the fill plug and test the operation of 

the jack.

—If the jack did not perform properly, then air 

may need to be bled from the pump system 
again.