-10-

G8694/G8695/G8889 Air Compressors

Fig 5. 

Air control lever in closed position.

Make sure the compressor model you use has
sufficient cubic feet per minute (CFM) output for
the air tool you plan to connect. Most air tools will
have an air requirement stated in terms of a spe-
cific CFM at a specific pressure (PSI). Consult the
chart below to determine the output of your com-
pressor model. 

Connecting Tools

Air Control Valve

G8294

G8295

G8889

2.0

2.5

2.0

3.0

3.5

4.2

7 gal

11 gal

4 gal

Model

HP

CFM

@ 90 PSI

Tank

Cap.

The compressor should put out a higher CFM
than the tool requires. If connecting multiple tools
which will be used simultaneously, then the CFM
for each tool should be added together and com-
pared to the compressor output value.

Consideration should also be given to the type of
usage. A nailer or staple gun uses air in short
bursts and it is easier for the compressor to main-
tain pressure. A paint sprayer or grinder tends to
use a more continuous stream of air as these
tools are run for longer time periods. It is always
better to oversize a compressor to allow for vari-
ation in the type of usage and the number of tools
to be powered. Air tools being operated with
insufficient air volume will not perform their func-
tion satisfactorily.

Connect the tool using a good quality air line with
an adequate length to reach from the compressor
to the point of use. Quick-connect couplers are a
good option for fast and sure connection of tools
and air hoses. Make certain the air hose will not
be placed in a position where it can become con-
stricted or cut by a sharp object. Having a hose
run over by heavy vehicles may not cause an
immediate leak, but it will shorten the life of the
hose. 

The air control valve lever is located just next to
the On/Off switch near the air outlet fitting. When
the lever is turned so it is in line with the fitting,
the valve is OPEN. When it is at a 90˚ position
relative to the fitting, the valve is CLOSED. (

See

Figure 5).

The air outlet supplied is a brass barb fitting
over which an air hose can be slipped. This
will be suitable for low pressure uses. If you
will be operating at higher pressure, or run-
ning air tools, you should replace this fitting
with a quick connect coupler which you can
find at your local hardware store.

Air Control Valve

Lever

There is also a pressure release valve which can
be used when decompression of the storage tank
is needed quickly and efficiently. Pull the metal
ring to release the pressure.

Summary of Contents for G8694

Page 1: ...NSTRUCTION MANUAL COPYRIGHT 1999 BY GRIZZLY INDUSTRIAL INC 1821 VALENCIA ST BELLINGHAM WA 98226 WARNING NO PORTION OF THIS MANUAL MAY BE REPRODUCED IN ANY SHAPE OR FORM WITHOUT THE WRITTEN APPROVAL OF GRIZZLY INDUSTRIAL INC NOVEMBER 1999 PRINTED IN CHINA G8694 G8695 G8889 ...

Page 2: ... 5 GROUNDING 5 EXTENSION CORDS 5 SETTING UP AND OPERATING COMMENTARY 6 UNPACKING 7 SITE CONSIDERATIONS 7 PREPARING FOR USE 8 STARTING 9 PRESSURE REGULATOR 9 CONNECTING TOOLS 10 AIR CONTROL VALVE 10 MAINTENANCE EACH USE 11 AFTER FIRST 50 HOURS 12 WEEKLY 12 EVERY 300 HOURS 12 TROUBLESHOOTING 13 PARTS BREAKDOWN AND PARTS LISTS 14 15 WARRANTY AND RETURNS 16 ...

Page 3: ...mable or noxious fumes may exist Keep work area well lighted For Your Own Safety Read Instruction Manual Before Operating This Equipment Indicates an imminently hazardous situation which if not avoided WILL result in death or serious injury Indicates a potentially hazardous situation which if not avoided COULD result in death or serious injury Indicates a potentially hazardous situation which if n...

Page 4: ... AMP RATING 25ft 50ft 100ft 0 6 18 16 16 7 10 18 16 14 11 12 16 14 12 13 16 14 12 12 17 20 12 12 8 21 30 10 10 No Safety Instructions For Power Tools 13 DON T OVERREACH Keep proper foot ing and balance at all times 14 MAINTAIN TOOLS WITH CARE Keep tools sharp and clean for best and safest performance Follow instructions for lubri cating and changing accessories 15 DISCONNECT TOOLS before servicing...

Page 5: ... This is preset to 150 PSI Operating this equipment has the potential to propel debris into the air which can cause eye injury Always wear safety glass es or goggles when operating equipment Everyday glasses or reading glasses only have impact resistant lenses they are not safety glasses Be certain the safety glass es you wear meet the appropriate stan dards of the American National Standards Inst...

Page 6: ...us injury may occur In the event of an electrical short grounding reduces the risk of electric shock by providing a path of least resistance to disperse electric cur rent These machines are equipped with power cords having an equipment grounding conductor See Figure 1 The outlet must be properly installed and grounded in accordance with all local codes and ordinances These air compressors are wire...

Page 7: ...ess below Grizzly Industrial Inc C O Technical Documentation P O Box 2069 Bellingham WA 98227 2069 Most importantly we stand behind our machines If you have any service questions or parts requests please call or write us at the location listed below Grizzly Industrial Inc 1203 Lycoming Mall Circle Muncy PA 17756 Phone 570 546 9663 Fax 800 438 5901 E Mail techsupport grizzly com Web Site http www g...

Page 8: ...ion 2 Circuit Requirements for the needs for your particular compressor Also make sure the compressor is not operating in an environment where there are any explosive flammable or caustic fumes or gases A clear and well ventilated area is best for its safe operation Place the compressor on a solid and level sur face Make sure that the hoses you attach to sup ply your pneumatic device will be unres...

Page 9: ...ve impact resistant lenses they are not safety glasses Be certain the safety glass es you wear meet the appropriate stan dards of the American National Standards Institute ANSI Operating this equipment has the potential for hearing damage to occur especially if operated for a long period of time Use ANSI American National Standards Institute approved ear muff or ear plugs when using this equipment...

Page 10: ... button on top of the control box should be in the fully depressed position see Figure 3 before connecting to the power supply Close the drain cock on the tank Pull the switch to the ON position Starting Fig 3 Start switch and gauges Check the pressure gauge to see that the tank pressure gets up to approximately 110 115 PSI On Off Switch Output Gauge Figure 4 Pressure regulator Always wear safety ...

Page 11: ...ools to be powered Air tools being operated with insufficient air volume will not perform their func tion satisfactorily Connect the tool using a good quality air line with an adequate length to reach from the compressor to the point of use Quick connect couplers are a good option for fast and sure connection of tools and air hoses Make certain the air hose will not be placed in a position where i...

Page 12: ...ding upon the amount of use and the weather conditions a certain amount of condensed water may be released For longevity of the compres sor seals and the air tools you connect it is best to keep the tanks free of water The tanks are best drained if the drain cocks are opened when the system is pressurized Once water has stopped coming out you can close the drain cocks Each Use Fig 6 Typical locati...

Page 13: ...essors Weekly Every 300 Hours If the compressor is used on a regular daily basis perform the following checks each week 1 Rinse the air filter foam element in water 2 Check for loose bolts or fittings After every 300 hours or 3 months of regular operation perform the following maintenance items 1 Change compressor motor oil 2 Rinse the air filter foam element in water 3 Check for air leaks and cor...

Page 14: ...ns 3 Motor will not start if tank pressure is too high 4 Thermal overload switch has tripped wait for motor to cool then reset switch by pressing red button 1 Inspect cord or plug for damaged insulation and shorted wires 2 Inspect all connections on motor for loose or shorted terminals or worn insulation 3 Install correct fuses or circuit breakers 1 Check air hoses and all connections for leaks 2 ...

Page 15: ...r 035 P8694035 Valve Gasket 036 P8694036 Valve Plate 037 P8694037 Check Valve 038 P8694038 Valve Inner Gasket 039 P8694039 Valve Plate 040 P8694040 Cylinder Head Gasket 041 P8694041 Cylinder Head 042 P8694042 Right Angle Connector 043 P8694043 Hex Bolt M6 x 50 044 P8694044 Air Filter 045 P8694045 Washer 4 mm 046 P8694046 Wing Nut M4 047 P8694047 Nut M6 048 P8694048 Capacitor 049 P8694049 Fan Cover...

Page 16: ...G8694 G8695 G8889 Air Compressors 15 ...

Page 17: ...shall be tried in the State of Washington County of Whatcom We shall in no event be liable for death injuries to persons or property or for incidental contingent spe cial or consequential damages arising from the use of our products To take advantage of this warranty contact us by mail or phone and give us all the details We will then issue you a Return Number which must be clearly posted on the o...

Reviews: