-62-
Model G0771 (Mfd. Since 8/15)
6. Loosen (4) table mounting bolts securing
table top to base (see
Figure 118), and lightly
tap table in direction needed to square table
to blade.
8. Tilt blade to 45° and recheck miter slot-to-
blade parallelism.
—If blade is still parallel with miter slot, no
additional adjustments need to be made.
—If blade was parallel with miter slot at 0°
but not at 45°, one end of table will need to
be shimmed higher with metal shim stock.
Continue to
Step 9.
9. Loosen (4) table mounting bolts from Step 6.
Mounting
Bolts
Figure 118. Location of table mounting bolts
(table omitted for clarity).
7. Repeat Steps 2–6 until blade and miter
slot are parallel, then tighten retighten table
mounting bolts.
10. Refer to Figures 119–120 for shim place-
ment. If distance A is shorter than B, shim(s)
will need to be placed under corners #1 and
#2. If the distance of B is shorter than A,
shim(s) will need to be placed under corner
#3. Very thin shim stock works well.
Figure 119. Shim procedure diagram A.
STEP A
Front
#1
#2
#3
Figure 120. Shim procedure diagram B.
#1
#2
#3
Front
STEP B
Summary of Contents for G0771