![Grizzly G0603X Owner'S Manual Download Page 35](http://html1.mh-extra.com/html/grizzly/g0603x/g0603x_owners-manual_2266990035.webp)
G0603X 25" Extreme Series Planer
-33-
Review the troubleshooting and procedures in this section to fix your machine if a problem develops. If you
need replacement parts or you are unsure of your repair skills, then feel free to call our Technical Support
at (570) 546-9663.
SECTION 7: SERVICE
Troubleshooting
Motor & Machine Operation
Symptom
Possible Cause
Possible Solution
Motor will not start.
1. Planer headstock cover is not closed,
or limit switch is at fault
2. Thermal overload relay inside mag-
netic switch has tripped.
3. Incorrect voltage.
4. Open circuit in motor or loose connec-
tions.
5. Emergency stop button depressed.
1. Close cover and/or replace/adjust limit
switch.
1. Unplug machine, open magnetic switch
cover, turn amperage dial on the thermal
overload relay to a higher setting.
2. Check power supply for proper voltage.
3. Inspect all lead connections on motor for
loose or open connections.
4. Rotate clockwise until it pops out/replace.
Fuses or circuit breakers blow.
1. Short circuit in line cord or plug.
1. Repair or replace cord or plug for damaged
insulation and shorted wires.
Motor overheats or operates at lim-
ited RPM.
1. Motor overloaded during operation.
2. Motor is miswired.
1. Reduce cutting load; take lighter cuts.
2. Rewire/replace motor.
Motor stalls or shuts off during a
cut.
1. Motor overloaded during operation.
2. Thermal overload protection is set too
low.
3. Short circuit in motor or loose connec-
tions.
4. Circuit breaker tripped.
1. Reduce cutting load; take lighter cuts.
2. Unplug machine, open magnetic switch
cover, turn amperage dial on the thermal
overload relay to a higher setting.
3. Repair or replace connections on motor for
loose or shorted terminals or worn insula-
tion.
4. Install correct or repair circuit breaker;
reduce number of machines running on
that circuit.
Cutterhead slows or squeals when
cutting, especially on start-up.
1. V-belt loose.
2. V-belt worn out.
1. Tighten V-belt (
Page 30
).
2. Replace V-belt (
Page 30
).
Loud repetitious noise coming from
machine.
1. Pulley set screws or keys are missing
or loose.
2. Motor fan is hitting the cover.
3. V-belts are damaged.
1. Inspect keys and setscrews. Replace or
tighten if necessary.
2. Adjust fan cover mounting position, tighten
fan, or shim fan cover.
3. Replace V-belts (
Page 30
).
Vibration when running or cutting.
1. Loose or damaged cutterhead.
2. Damaged V-belt.
3. Worn cutterhead bearings.
1. Tighten or replace cutterhead.
2. Replace (
Page 30
).
3. Check/replace cutterhead bearings.
Summary of Contents for G0603X
Page 2: ... ...
Page 5: ...G0603X 25 Extreme Series Planer 3 Machine Data Sheet ...
Page 6: ... 4 G0603X 25 Extreme Series Planer ...
Page 10: ... 8 G0603X 25 Extreme Series Planer ...
Page 11: ...G0603X 25 Extreme Series Planer 9 Safety Instructions for Machinery ...
Page 51: ...G0603X 25 Extreme Series Planer 49 Page 47 Page 51 Page 51 Page 50 Page 50 Page 50 Page 48 ...
Page 52: ... 50 G0603X 25 Extreme Series Planer Page 49 Page 48 Page 49 ...
Page 53: ...G0603X 25 Extreme Series Planer 51 Page 49 ...
Page 54: ... 52 G0603X 25 Extreme Series Planer Base Parts Breakdown ...
Page 57: ...G0603X 25 Extreme Series Planer 55 Column Parts Breakdown ...
Page 59: ...G0603X 25 Extreme Series Planer 57 Electric Parts Breakdown ...
Page 61: ...G0603X 25 Extreme Series Planer 59 Gearbox Parts Breakdown ...
Page 63: ...G0603X 25 Extreme Series Planer 61 Headstock Parts Breakdown ...
Page 65: ...G0603X 25 Extreme Series Planer 63 Table Parts Breakdown ...
Page 68: ......
Page 69: ... ...
Page 70: ... ...
Page 72: ... ...