3.4 Electrical connection
A supply cable 3x1.5mm
2
minimum is needed.
One end of the supply cable must be fixed through the cable clip (Pict.7) and then connected to the
terminal box, as shown in Pict.8. Make sure that negative and positive polarities are respected
(GND/Neutral/Phase).
Furthermore ensure that the cable clip screw nut is properly tightened, so that the unit will be dust
and water jet proofed.
3.5 DMX line connection
Remove the screw stoppers of the bushes relevant to the digital data cables, as shown in Pict.9.
IN cable: one end of the DMX digital cable must be fixed through the cable clip and then connec-
ted to the terminal. The polarity which is written on the label must be respected (GND, DATA -,
DATA +).
If the projector is the last unit of a line, do not remove the screw stopper referring to the missing
OUT cable. If the projector is not the last unit of a line, connect the OUT cable through the screw
stopper which is still available.
OUT cable: connect the OUT cable to the terminal, together with the IN cable (Pict.9). Make sure
that the screw stoppers are properly tightened, so that protection against dust and water jets is ensu-
red.
Note: If the control signal cables are not connected, do not remove any of the screw stoppers.
13
POWER
IN
DMX IN
DMX
OUT
picture 7
picture 8
picture 9