background image

AL4484  nanoParade - Rev. 1.00

100-277 V

ac

100-277 V

ac

120 Ω  Resistor

AL4487/ 3

LINE END CAP

DMX CONTROLLER

A

L 4487/ 2

 - IP67 Power Supply 120W

nanoParade L=320 mm 

ACTIVE

 

nanoParade L=320 mm Slave

PASSIVE

 

AL4487

 Startline Cable

24 V

dc

24 V

dc

AL0512

DMX Cable or equivalent

AL0512

DMX Cable or equivalent

-

Use a DMX repeater on each 32nd 

ACTIVE fixture of the daisy-chain or in case the total DMX cabl

e length exceeds 1000 ft ( 300 m.)

-

Install a 120 Ω resistor on the DMX OUT

 cable of the last Startline Cable of the daisy-chain as descri

bed in the 

AL4487 Startline Cable manual.

-

For further details on fixture connection and installation, ple

ase refer to the relevant instruction manual.

-

This is only an example of a possible configuration scheme. Oth

er configurations can be tailores to the client’

s needs.

AL4487/ 3

LINE END CAP

nanoParade L=320 mm Slave

PASSIVE

 

nanoParade L=320 mm Slave

PASSIVE

 

Maximum length of the chain: 5 m

 

( 16X nanoParade 320 or 8X nanoParade 620 or 4X nanoPara

de 1220 )

It’

s possible to install fixtures of dif

ferent lengths.

An 

ACTIVE fixture is always required at the beginnig of the dai

sy-chain.

Summary of Contents for nanoParade AL4484

Page 1: ...Protezione termica Electronic Electrical class Classe elettrica III Cable length Lunhezza del cavo 200 mm Control system Sistema di controllo USITT DMX 512 RDM only RGB version DMX Channels Canali 3...

Page 2: ...26mm 1 20 mm 3 4 nanoParade 1220 mm 200 mm 7 7 8 1220 48 20 mm 3 4 26 mm 1 50 mm 2 nanoParade is shown here in the version with connectors A version with 200 mm cable without connectors is also avail...

Page 3: ...tors unconnected or unprotected for long periods Non lasciare mai per lungo tempo agli agenti atmosferici cavi e connettori non collegati o non protetti Disconnect power before installing or servicing...

Page 4: ...off before connecting or disconnecting fixtures ATTENZIONE Assicurarsi che l alimentazione sia disattivata prima di collegare o scollegare i proiettori Standard version 196 6 50 496 548 548 nanoParad...

Page 5: ...Rev 1 00 Press and slot the led bar into the profile previously fixed to the ground or wall Premere ed incastrare a pressione la barra led sul profilo precedentemente fissato al terreno o al muro PRE...

Page 6: ...nces 6 30 270 30 30 470 30 30 nanoParade 320 mm nanoParade 620 mm nanoParade 1220 mm Fix the fixture to the ground or wall through the holes in the bracket Fissare l apparec chio al terreno utilizzand...

Page 7: ...zando il kit di con nessione in dotazione al proiettore Seguite le istruzioni fornite con il kit Connecting RDM functions When operating in DMX mode the fixture can accept the following RDM commands d...

Page 8: ...MX After two seconds since supply the LED flashes as many times as the sets of ten Celsius degrees measured by the thermic sensor For exemple if the temperature is between 20 and 29 two short shut dow...

Page 9: ...AL4484 nanoParade Rev 1 00 Configurations Scheme...

Page 10: ...e DMX OUT cable of the last Startline Cable of the daisy chain as described in the AL4487 Startline Cable manual For further details on fixture connection and installation please refer to the relevant...

Page 11: ...AL4484 nanoParade Rev 1 00...

Page 12: ...AL4484 nanoParade Rev 1 00...

Reviews: