AL4362-AL4663-AL4364 MicroParade - Rev. 1.00
page 5 of 8
551047
Configurations
MicroParade 12
MicroParade 24
MicroParade 12
MicroParade 12
MicroParade 12
MicroParade 24
MicroParade 24
MicroParade 24
MicroParade 36
MicroParade 36
MicroParade 36
MicroParade 36
MicroParade 12
MicroParade 36
MicroParade 24
MicroParade 24
Microparade ?
Unit 1
Unit 2
Unit 3
Unit
44
Unit
28
Unit
21
Unit x
Unit 1
Unit 2
Unit 3
Unit 1
Unit 2
Unit 3
Unit 1
Unit 2
Unit 3
Unit 3
0,11A x 45 = 4,95A (< 5A)
0,17A x 29 = 4,93A (< 5A)
0,23A x 21 = 4,83A (< 5A)
Total load ≤ 5A
Start line box
AL4400
Repower box
AL4401
AL0512 DMX cable or equivalent
DMX
CONTROLLER
POWER IN
100-240 VAC
50/60Hz
POWER IN
100-240 VAC
50/60Hz
Use a DMX repeater on each 32nd fixture of the daisy chain
•
or in case the total DMX cable length exceeds 1000 ft (300m).
Install a data terminator on the DMX OUT cable of the last unit
•
of the daisy chain as described in the DMX connection kit manual.
For further details on fixture connection and installation,
•
please refer to the relevant instruction manual.
120Ω DMX
TERMINATOR
The total load of each series of Microparade must not exceed 5 A.
Il carico totale di ogni singola serie di Microparade non deve superare 5 A.
Example/Esempio:
WARNING ! Use a DMX repeater on each 32nd fixture of the chain or in case the cable lenght exceeds 300m (
1000 ft.). Install a data terminator ( 120Ω) between Data+ and Data- on the DMX out cable of the last unit.
ATTENZIONE ! Utilizzare un ripetitore di segnale DMX ogni 32° proiettore della catena o nel caso la lunghezza del
cavo superi 300 m ( 1000 ft.). Installare un terminatore di linea ( 120 Ω ) tra i poli Data+ e Data- sul cavo dell’ulti
-
mo proiettore.
For further details consult the configuration schemes available on our website.