4.3 Powering up the unit
The unit can operate with standard 350mA led driver.
4.4 Connection from microDUNE and Transformer box
microDUNE
Minimum 1 unit - Maximum 4 unit
Before power up the device, select the number of units connected
by the selector "C", which is near the dip-switch panel !!
Transformer box
AL1855
C
Warning!
• Before connecting the unit, verify that power supplies features are compatible with the unit features.
• Wiring and connection actions are to be performed by a qualified staff.
Warning!
To connect the power supply, EXCLUSIVELY the connectors enclosed to this manual are to be used,
in order to preserve the IP67 weather protection rate.
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
N.C.
RED+
GREEN+
GREEN-
BLUE-
RED-
BLUE+
N.C.
Polarity and colours correspondence of the
connection cables must be strictly respected.
Ø cable: 6÷8 mm
minimum section: 6 x 0.32mm²
16
English