3.4 Electrical connection

1) Cable the 16 Amps Gewiss plug to a mains cable 3x2,5mm

2

.

2) Connect the lantern to a mains supply of 230V - 50/60Hz.
3) Ensure that the mains cable is connected to earth; the thermoswitch must have the following
electrical characteristics: 
lamp 1200 HMI = rated for  (In) 20A - sensitivity (Id) 0,3A
lamp 2500 HMI = rated for  (In) 25A - sensitivity (Id) 0,3A

4.0 USE OF THE PROJECTOR
4.1 Switching on the unit

Connect the unit to power supply (make sure that needed operating voltage is respected) and turn
the main switch, located on the base, on. The unit can work according to 3 basic modes: manual
mode, manual by DMX mode, DMX mode.

4.2 Control panel

1
2

3

A001 = DMX ADDRESS CHANGE

B000 = BLACK-OUT

R000 = MIRROR DISH ROTATION

P000 = PAN MOVEMENT

S000 =  PAN MOVEMENT SPEED

MAN = MANUAL MASTER

FLASHING GREEN LED = NO DMX SIGNAL

GREEN LED FIXED = DMX SIGNAL

MENU

UP

DOWN ENTER

DMX IN

DMX OUT

3

12

1 GND

2 DATA -

3 DATA +

Control Panel

Summary of Contents for GR 0021 HMI 1200

Page 1: ...Foglio di Istruzioni Instructions SKY ROSE MK2 GR 0021 HMI 1200 GR 0025 HMI 2500 GR025 Rev 1 17 Feb 2006...

Page 2: ...unzionamento in manuale 5 4 6 Funzionamento in manuale con DMX 6 4 7 Funzionamento con DMX 6 5 0 MANUTENZIONE 7 6 0 INFORMAZIONI TECNICHE 7 7 0 PARTI DI RICAMBIO 7 INDEX INDEX Page 1 0 PACKING 8 2 0 S...

Page 3: ...i 3 0 INSTALLAZIONE DEL PROIETTORE 3 1 Rimozione dei pannelli di fissaggio Togliete il pannello anteriore ed il pannello posteriore utilizzati per il fissaggio della parte superiore del proiettore dur...

Page 4: ...ento Id 0 3A proiettore 2500 corrente nominale In 25A valore d intervento Id 0 3A 4 0 USO DEL PROIETTORE 4 1 Accensione del proiettore Collegato il proiettore alla tensione indicata e attivato l inter...

Page 5: ...amite i pulsanti UP e DOWN selezionare il valore H come mostra la figura a lato premere ENTER per confermare Ora il proiettore esegue le escursioni di PAN e ROTAZIONE COPPA Per modificare la velocit d...

Page 6: ...ritto pin 1 function GND SHIELD pin 2 function SIGNAL pin 3 function SIGNAL Verificate che i fili siano correttamente collegati nel connettore e che essi non ne tocchino il guscio utilizzate filo sche...

Page 7: ...ciato nero Tensione nominale V 230 230 Frequenza nominale Hz 50 60 50 60 Corrente nominale A 8 14 5 Potenza assorbita VA 2000 3000 Lampada consigliata HMI 1200 HMI 2500 attacco SFC 15 5 6 attacco SFA...

Page 8: ...t temperature must not exceed 35 C Caution the surface temperature of the projector can reach 95 C Caution hot lamp ensure that the lamp is cold before attempting to remove it about 20 minutes 3 0 INS...

Page 9: ...0 3A 4 0 USE OF THE PROJECTOR 4 1 Switching on the unit Connect the unit to power supply make sure that needed operating voltage is respected and turn the main switch located on the base on The unit...

Page 10: ...ee times the MENU key to select the manual mode Select the H value by using the UP DOWN keys see picture on the side Press ENTER to confirm With this setting the unit performs the PAN MOVEMENT and the...

Page 11: ...s follows Pin 1 function GND SHIELD Pin 2 function SIGNAL Pin 3 function SIGNAL Make sure that wires are correctly fitted into the connector wires must not touch the connector shell use shielded wires...

Page 12: ...8 14 5 Power absorbed VA 2000 3000 Suggested Lamp HMI 1200 HMI 2500 SFC 15 5 6 Base SFA 21 12 Base Optical System 1 Lens PCX dia 230 R350 1 Lens PCX dia 230 R350 Fuse n 1 5x20 250V 3 25A n 1 5x20 250...

Page 13: ...13...

Page 14: ......

Page 15: ......

Page 16: ...LENGE Professional Lighting Manufacturer Via Bulgaria 16 46042 CASTEL GOFFREDO MN Telefono 0376 779483 Fax 0376 779682 0376 779552 http www griven com e mail griven griven com http www griven it e mai...

Reviews: