MAINTENANCE
All lanterns require regular maintenance to ensure maximum performance and light output.
Please follow these instructions:
- clean lenses regularly, as even a thin layer of dust can reduce the light output and scatter the
beam;
- replace the lamp if it has become damaged or it's thermally deformed;
- carefully check the electrical connections, particularly the earth connection;
- replace lenses if they have become visibly damaged;
- replace all the damaged components
TECHNICAL INFORMATION
SPARE PARTS
All components are available for the FRISBY and the exploded diagram and catalogue are availa-
ble on request.
FRISBY
Size
mm
330x360x230
Weight
kg
4,2
Body
Fe 37 - black painted
Operating voltage
V
230
Operating frequence
Hz
50/60
Operating amperage
A
4
Power absorbed
W
800
Suggested lamp
Alogen 800W
DXX
Optical System
8 Rectangular lenses 40x80
Max Working Temperature
°C
120
Max Ambient Temperature
°C
50
Summary of Contents for FRISBY