MAINTENANCE

All lanterns require regular maintenance to ensure maximum performance and light output.
Please follow these instructions: 
- clean lenses regularly, as even a thin layer of dust can reduce the light output and scatter the
beam;  
- replace the lamp if it has become damaged or it's thermally deformed;
- carefully check the electrical connections, particularly the earth connection;
- replace lenses if they have become visibly damaged;
- replace all the damaged components 

TECHNICAL INFORMATION

SPARE PARTS

All components are available for the FRISBY and the exploded diagram and catalogue are availa-
ble on request.

FRISBY

Size

mm

330x360x230

Weight

kg

4,2

Body

Fe 37 - black painted

Operating voltage

V

230

Operating frequence

Hz

50/60

Operating amperage

A

4

Power absorbed

W

800

Suggested lamp

Alogen 800W

DXX

Optical System

8 Rectangular lenses 40x80

 

Max Working Temperature

°C

120

Max Ambient Temperature

°C

50