background image

551118

AL5003 Dune MK3

page 8 of 9

DMX charts

RDM functions:

When operating in DMX mode the fi xture can accept the following RDM commands:

• discovery: Upon request of the RDM controller, the fi xture signals its own presence (the RDM controller will display the fi xture on a list).

• DMX address reading and setting.

• Channels number reading and setting.

• On / Off identifi cation: This command is used to identify the fi xture you want to get access to (the identifi cation happens by switching on all the LEDs at full 

intensity).

• Manufacturer: it displays the name of the manufacturer (Griven).

• Model description: it displays the fi xture’s model.

• Software version description: it displays the current version of the fi rmware.

• Temperature: it displays the LEDs operating temperature value.

In modalità DMX il proiettore accetta i seguenti comandi RDM:

· discovery: dierto richiesta del controller, il proiettore segnala la sua presenza ( il controller evidenzierà il proiettore su una lista).

· Lettura ed impostazione dell’indirizzo DMX.

· Lettura ed impostazione del numero di canali.

· On/Off identifi cation: questo comando è usato per rintracciare l’unità sulla quale si vuole operare ( il proiettore si metterà in evidenza accendendo tutti 

i LED a massima intensità).

· Manufacturer: viene mostrato in nome del produttore ( Griven ).

· Model description: viene mostrato il modello del proiettore.

· Software version description: viene mostrata la attuale versione software installata sull’apparecchio.

· Temperature: viene mostrata l’attuale temperature dei LED.

Mode

Modo

Channel

Canale

Function

Funzione

Value

Valore

4

1

0-100% Red

0-255

2

0-100% Green

0-255

3

0-100% Blue

0-255

4

0-100% White

0-255

5

1

0-100% Red

0-255

2

0-100% Green

0-255

3

0-100% Blue

0-255

4

0-100% White

0-255

5

Dimmer 100%

0-015

Dimmer 100% - 0%

016-150

Dimmer 0%

151-160

0-100% Strobo

161-255

6

1

0-100% Red

0-255

2

0-100% Green

0-255

3

0-100% Blue

0-255

4

0-100% White

0-255

5

0% Dimmer

0-5

100-0% Dimmer

6-250

100% Dimmer

251-255 

6

No Strobo

0-5

0-100% Strobo

6-250

100% Strobo

251-255

RGBW 

Mode

Modo

Channel

Canale

Function

Funzione

Value

Valore

2

1

100%warm 0%cold

0-3

100%warm-

0%→100% cold

4-122

100% warm

100% cold

123-132

100%→0% warm

100% cold

133-251

0% warm

100% cold

251-255

2

Dimmer 100%

0-015

Dimmer 100% - 0%

016-150

Dimmer 0%

151-160

Strobo 0% - 100%

161-255

3

1

0%→100% warm

0-255

2

0%→100% cold

0-255

3

Dimmer 100%

0-15

Dimmer 100% - 0%

016-150

Dimmer 0%

151-160

Strobo 0% - 100%

161-255

DW (Dynamic White)

Note:

W and DW

 versions: in absence of DMX signal the LEDs will remain on.

RGBW

 version: in absence of DMX signal the LEDs will remain off.

Versioni 

W e DW

: in assenza di segnale DMX i LED rimarranno accesi.

Versione 

RGBW

: in assenza di segnale DMX i LED rimarranno spenti.

Channel

Canale

Function

Funzione

Value

Valore

1

Dimmer 100%

0-015

Dimmer 100% - 0%

016-150

Dimmer 0%

151-160

Strobo 0% - 100%

161-255

Monochromatic version

Summary of Contents for AL5003

Page 1: ...L stainless steel in ABS formwork IK rating classe IK IK10 IP rating grado IP IP68 1 5M Ambient temp Temperatura ambientale 40 C to 50 C 40 F to122 F Power supply Alimentazione 100 240 VAC 50 60Hz Inr...

Page 2: ...ll apparecchiatura Disconnect power before any connection operation Togliere l alimentazione prima di effettuare qualsiasi operazione di connessione tra gli apparecchi Check voltage and frequency befo...

Page 3: ...551118 AL5003 Dune MK3 page 3 of 9 Installation 1 2 3 4 5 6 8 9 40 10 7 2 4 6 8 40 10 1 2 3 4 5 6 8 40 7 2 4 6 8 40 1 2 3 4 5 6 8 40 7 2 4 6 8 40 M5 M6 Installazione...

Page 4: ...ATERIAL MATERIALE DI DRENAGGIO 0 mm Aim this sticker towards the wall that should be illuminated Orientare questa segno verso il muro da illuminare Installazione Never install the formwork below groun...

Page 5: ...Km Mains Power 100 240 VAC 50 60Hz Mains Power 100 240 VAC 50 60Hz DMX cable type 2x0 34 mmq shielded impedance 110 capacity 43pF m resistance 50 Km Beam aimig Beam angle can be varied from 9 to 9 Re...

Page 6: ...non devono essere presenti altri controller DMX sulla linea MASTER SLAVE AUTOMATIC mode SLAVE 2 eg CH001 OUT IN DMX cable OUT IN DMX cable OUT IN DMX cable Line terminator 120 not included SLAVE 1 eg...

Page 7: ...LUE BLU 4 WHITE BIANCO DIMMER MODE Monochromatic 0 100 100 0 5 inactivity Automatic LOGOUT 5 inattivit Automatic LOGOUT Green Cyan Blue Magenta Red Yellow White Verde Ciano Blu Magenta Rosso Giallo Bi...

Page 8: ...strato il modello del proiettore Software version description viene mostrata la attuale versione software installata sull apparecchio Temperature viene mostrata l attuale temperature dei LED Mode Modo...

Page 9: ...ando il proiettore se la temperatura lo richiede si scalda il vetro termico che rimane attivo no al raggiungimento della temperatura di esercizio POWER ON LEDs OFF LEDs ON If the projection is to be s...