6.2 Connection to mains power
The unit can operate with voltage from 100 to 240Vac with frequency of 50 and 60Hz.
Connect the main cable to the terminal box
“5”
.
The connection of the cable to the unit must be performed respecting the label next to the terminal box.
Size and connection scheme of the main cable are shown in the following picture.
6.3 Connection to DMX signal
The DMX signal is to be connected by using a shielded cable designed for devices RS-485.
The unit is fitted with pins for the connection of the DMX signal cable, as shown in the following pictures.
The connection of the cable to the unit must be performed respecting the label next to the terminal box, while
from the end of the DMX controller the connection must respect the following table:
pin 1 = GND
pin 2 = data -
pin 3 = data +
For DMX devices with 5 poles connectors, pins 4 and 5 are not to be connected.
Warning!
• Before connecting the unit, verify that power supplies features are compatible with the unit features.
• The unit must never be installed if not grounded electrically.
• It is suggested to use a magnetothermic switch along the power supply line, as prescribed by in force rules.
• The unit must not be powered up through a dimmer power device.
• Wiring and connection actions are to be performed by a qualified staff.
L
Ground
N
Neutral
Phase
5
3x1.5mm
²
minimum
cable section
18
English