English
19
5.3 DMX functions
5.3.1 DMX functions with 6 Ch = OFF
5.3.2 DMX functions with 6 Ch = ON
Parade
can operate without DMX signal (in AUTOMATIC mode) and can be set so that a single MASTER unit will
command a series of SLAVE units. This function is particularly useful when more units are desired to execute the
same programme in synchrony.
The following picture shows an example of a Master-Slave layout.
Channel Function
Value
Description
1
Red
0-255
Proportional control 0-100% of the Red color
2
Green
0-255
Proportional control 0-100% of the Green color
3
Blue
0-255
Proportional control 0-100% of the Blue color
4
Dimmer
Strobe
0-15
Luminous output intensity 100%
16-160
Proportional control of the luminous output intensity 0-100%
161-255
Proportional control of the strobe effect 0-100%
Channel Function
Value
Description
1
Red
0-255
Proportional control 0-100% of the Red color
2
Green
0-255
Proportional control 0-100% of the Green color
3
Blue
0-255
Proportional control 0-100% of the Blue color
4
Strobe
0-3
No strobe
4-63
Proportional control 0-100% of the strobe effect
64-66
No strobe
67-126
Proportional control 0-100% of the strobe effect with slow opening
and fast closing
127-129
No strobe
130-189
Proportional control 0-100% of the strobe effect with fast opening and
slow closing
190-192
No strobe
193-252
Proportional control 0-100% of the strobe effect with slow opening
and slow closing
253-255
No strobe
5
Dimmer
0-255
Proportional control of the luminous output intensity 0-100%
6
Preset
colours
0-255
62 preset c white
6.0 Master-Slave and Automatic function