4.4 DMX cable connection
4.5 MASTER-SLAVE mode
More TIROS EYEBALL units can be set to "Slave" option to follow the "Master" unit in synch-
rony. The "Master" unit must be set with the relevant dip-switch in the ON position; the "Slave"
units must be set with all relevant dip-switches in the OFF position.
The DMX specifications require a 100-120 ohm terminal resistor, which must be fitted between
the DATA+ and DATA- Pins in the last unit of the DMX line. For each DMX line select Master
mode or DMX mode, but not both of them, because in this last case the electrical line may be
damaged.
15
Use 2-pole shielded cable
+ hose (GND)
The hose (GND) must not
touch metal parts
7
Calza
Hose
Data +
Data -
GND
Min.Sect.
0.35 mm
Junction box for the
DMX cable connection
Terminale
di linea
Slave
Master
Slave
Slave
Line
terminal