background image

SPECIFICATIONS

MODEL

VOLTAGE

POWER

LUMEN

TEMPERED GLASS

MAXIMUM PROJECTED 

AREA

NET WEIGHT 

19963

AC220-240V

10W

800LM

97.2x72.2x3.2mm

.35cm

2

0.5kg

19970

AC220-240V

20W

1600LM

122.6x87.6x3.2mm

.68cm

2

0.58kg

Note:

• 

Electric shock protection class: I

• 

External light protection class: IP65

•  Rated voltage: 220-240V~ 50Hz

•  Recommended power cord: H05RN-F3G1.0mm

2

ADJUSTMENT OF SENSOR

A: ADJUSTING THE SENSITIVITY: 

The sensitivity is the maximum distance from which the PIR 

Sensor can be triggered by moving persons. Turning the SENS 

dial button from (+) to (-) will decrease the sensitivity.

Maximum distance: 10±2M

Minimum distance: 4M

B: ADJUSTING THE DURATION TIME:

The duration of time that the projector remains switched 

on after activation can be adjusted from 10±5 seconds to 10 

minutes. Turning the TIME dial button from (+) to (-) will reduce 

the duration time.

C: ADJUSTING THE LUX CONTROL LEVEL: 

The Lux control module has a built-in sensing device (photocell) 

that detects daylight and darkness. Rotating the LUX dial button 

clockwise is from light (

) to dark (

). In the (

) position the 

projector can work day and night, and in the (

) position, the 

projector only switches on at night. You can install unit at the 

desired level by adjusting the LUX dial button.

SENS

+

TIME

+

LUX

Summary of Contents for 19963

Page 1: ...BRUGER MANUAL INSTRUCTION 19963 19970 LED projektør med sensor LED projector with sensor Brugermanual instruction for Gripo LED projektør LED projector DVA A S Meterbuen 26 2740 Skovlunde ...

Page 2: ...igede kontaktes en kvalificeret elektriker Sørg altid for at netspændingen er korrekt Udskift altid sikringen med en af samme mærke Hvis projektørens kabel eller ledninger beskadiges må de udelukkende udskiftes af fabrikanten eller dennes serviceagent eller en lignende kvalificeret person for at undgå en fare Kontroller at projektøren er sikkert monteret Sørg for at kablet ikke sidder fast på skar...

Page 3: ...r SENS drejeknappen fra til mindskes følsomheden Maksimal afstand 10 2M Minimumsafstand 4M B JUSTERING AF VARIGHEDEN Tiden hvor projektoren forbliver tændt efter aktivering kan justeres fra 10 5 sekunder til 10 minutter Hvis du drejer TIME drejeknappen fra til reduceres varigheden C JUSTERING AF LUX KONTROLNIVEAU Lux kontrolmodulet har en indbygget sensorenhed fotocelle der registrerer dagslys og ...

Page 4: ...hentes hos kommunens tekniske forvaltning Bru gere af elektrisk og elektronisk udstyr må ikke bortskaffe affald af elektrisk og elektronisk udstyr sammen med husholdningsaffald Brugere skal benytte de kommunale indsamlingsordninger for at mindske den miljømæssige belastning i forbindelse med bortskaffelse af affald af elektrisk og elektronisk udstyr og øge mulighederne for genbrug genanvendelse og...

Page 5: ...e er udvalgt med henblik på at sikre en høj kvalitet igennem hele programmet Blue electic produkterne er udviklet i en Ecologisk retninig for at sikre et bæredygtigt miljøvenligt produkt DK GRIPO is a range of electrical products designed tested and approved by DVA GRIPO products are manufactured with focus on quality value for money and ECO solutions Regardless of whether it is a floodlight a fan...

Page 6: ...s shown in Figure 4 below NOTE If your mains wiring differs in any way consult a qualified electrician Always ensure that the mains supply voltage is correct Always replace the fuse with one of an identical rating If the external flexible cord of this projector is damaged it must be replaced solely by the manufacturer or his service agent or a similar qualified person to avoid any hazard Check tha...

Page 7: ...NS dial button from to will decrease the sensitivity Maximum distance 10 2M Minimum distance 4M B ADJUSTING THE DURATION TIME The duration of time that the projector remains switched on after activation can be adjusted from 10 5 seconds to 10 minutes Turning the TIME dial button from to will reduce the duration time C ADJUSTING THE LUX CONTROL LEVEL The Lux control module has a built in sensing de...

Page 8: ...t was purchased They can take this product for environmental safe recycling Designation GRIPO LED projector 10 20 W with sensor Reference no 19963 19970 European Directive European Standard No 2014 35EU RoHS 2011 65 EU REACH EN 60598 1 2015 A1 2018 EN 60598 2 5 2015 EN 62493 2015 DECLARATION OF CONFORMITY We hereby declare that the following products described below conforms to the technical safet...

Page 9: ...terne af GRIPO produkterne er udvalgt med henblik på at sikre en høj kvalitet igennem hele programmet Blue electic produkterne er udviklet i en Ecologisk retninig for at sikre et bæredygtigt miljøvenligt produkt DK GRIPO is a range of electrical products designed tested and approved by DVA GRIPO products are manufactured with focus on quality value for money and ECO solutions Regardless of whether...

Page 10: ...DVA A S Meterbuen 26 2740 Skovlunde M info dva dk T 45 70 234 239 Gripo 19963 10 Gripo 19970 20 ...

Reviews: