MEK-PM
GRIP GmbH Handhabungstechnik Tel.: 0231/96450-01 www.grip-gmbh.com [email protected]
MBA-MEK-PM-EN
07/2019
Assembly and Operating
Manual
2.4 Safety indication
Dangers may arise from the unit if, e.g.:
▪
the product is not installed or inserted properly,
▪
the system is not used for the intended use,
▪
the safety and installation notes are not observed.
Everyone who is responsible for assembly, commissioning und maintenance , has to read and
understand the complete operating instructions. Principles of operation, that affect the function
und operational safety of the MEK are prohibited.
The unit may only be operated if the machine in which the unit is installed
complies with the relevant provisions of the Machinery Directive 2006-42-EC.
Before carrying out assembly, alteration, maintenance or adjustment, remove the
power supply and carry out the necessary work outside the danger zone.
2
2 Safety
2.1 Symbol
This symbol indicates possible dangers to persons or the multi energy coupling system.
2.2 Intended Use
The power coupling MEK series has been designed to operate pneumatic and/ or electrical
equipment. The module is intended for installation in a machine. The requirements of the
applicable directives must be considered and adhered to. The unit may only be used in the
context of its technical data.
2.3 Environmental and operating conditions
Use this unit only in dry and splash-proof environments at room temperature as well as within
the application parameters defined in the technical catalog. If this is not the case, warranty
cannot be accepted. Exceptions are units designed especially for the respective conditions.
3 Warranty
If the product is used as intended in 1-shift operation the warranty is valid for 24 months from
the ex-works delivery date under observance the mandatory maintenance and lubrication
intervals and the given operating conditions. Generally parts touching the work piece and wear
parts are not part of the warranty. Wear parts are listed in chapter 8.1. The unit is considered to
be
defective if its basic function “
Feeding through" is no longer maintained.
4 Scope of Delivery
•
MEK as painted in Image 2 and Image 3 depending on the order number of the upper or
lower part.
5 Technical Data
Behold technical data sheets: TD-MEK063-3PM5-1E12-EN, TD-MEK063-6PM5-1E12-EN, TD-
MEK080-6PM5-1E12-EN