background image

 

SET UP 
 

Before being used for the first time, your new compressor requires a simple set-up procedure 
that will help your unit deliver years of trouble-free service.     

 WARNING:  

Failure to follow all initial set-up instructions may result in serious damage 

to    your compressor, property damage, or serious injury to operator and bystanders.    Do not 
start compressor until all set-up steps have been performed.

 

 

1.  Remove dipstick and add lubricant to compressor crankcase.    Oil level must be 

between “Low” and “High” marks on dipstick.    Crankcase capacity is ll.8 oz. (350 ml).   
Use chart below for correct viscosity: 

 

Air Temperature

 

Viscosity

 

 

14 – 80 F 

 SAE 20 (ISO 68) 

 

40 – 80 F 

SAE 30 (ISO 100) 

2.  Install air filter in compressor head, and tighten securely. 
3.  Check power outlet circuit for correct capacity.    Compressor requires 120V, Single 

Phase, 14 Amps, 60 Hz. Fuses or circuit breakers must be rated accordingly. 

4.  Use an extension cord with 3-prong grounding plug sized to prevent power loss and 

overheating of the motor: 

 

Cord Length

 

Wire Gauge Size

 

 

up to 25 ft. 

 

12 ga. 

 

Up to 100 ft. 

 

10 ga. 

 

Up to 150 ft. 

 

8 ga. 

 

Up to 250 ft. 

 

6 ga. 

5.  Position compressor on a secure, stable surface, no more than 10 degrees off level. 
6.  Open one tank drain cock, and start compressor by pulling On/Off button out to the “ON” 

position.    Allow compressor to run for 10 minutes, then close drain cock. 

7.  Allow compressor to pressurize tanks. Watch for excessive vibration or unusual noise 

while compressor motor is running.  If unit vibrates excessively or makes unusual noise, 
shut compressor off by pressing On/Off button to “OFF” position.    Refer to trouble- 
shooting chart for corrective action. 

8.  Check operation of Pressure Relief Valve by pulling release ring out to exhaust air 

pressure from tank.    Release ring and allow pressure relief valve to reseat.    Contact 
your dealer if Pressure Relief Valve does not operate properly. 

9.  Compressor is now ready for regular operation. 

Summary of Contents for GR254CTS

Page 1: ...OPERATING MANUAL AND PARTS LIST MODEL GR254CTS COMPRESSOR Because quality work demands quality tools Distributed By PRIMESOURCE BUILDING PRODUCTS INC An Itochu Company 800 676 7777 ...

Page 2: ...ts List 12 Compressor Tank Schematic 13 Compressor Tank Parts List 14 Troubleshooting 15 Maintenance Procedures 17 Storage 17 Warranty 18 WARNING This manual contains important safety and operating instructions that must be followed You must read and understand this manual before operating this compressor Failure to follow all instructions can result in serious injury to operator and bystanders or...

Page 3: ...rious injury Keep guards and protective covers in place INHALATION HAZARD Compressed air can contain carbon monoxide or other harmful gases Do not use compressor to provide air for breathing BURST HAZARD Over pressurization caused by tampering with controls can cause serious injury or death from explosion SHOCK HAZARD Contact with live electrical components can cause shock serious injury or death ...

Page 4: ...ompressor use outdoors in garages and in damp locations USE AN EXTENSION CORD THAT IS PROPERLY SIZED Using an undersize cord can result in overheating of cord and short circuiting resulting in fire and damage to property Use a UL listed extension cord rated to safely handle the power requirements of the compressor DO NOT OPERATE IF FLAMMABLE VAPORS ARE PRESENT The electric motor and pressure switc...

Page 5: ... set at the factory provide the maximum safe operating pressure recommended for this compressor Altering these settings can result in over pressurization risk of tank hose and pneumatic equipment failure and serious injury to operator and bystanders USE AIR HOSE RATED FOR 150 PSI OR GREATER Air hose must be rated to safely handle maximum compressor pressure Air hose that does not meet minimum pres...

Page 6: ...90 PSI 4 cfm 100 PSI Pressure Switch Settings Pressure Switch ON 95 PSI Pressure Switch OFF 125 PSI Compressor Pump Cylinders 1 Compression Stage 1 Lubrication Splash Oil Type Compressor Oil SAE 30W ISO 100 Crankcase Aluminum Bearings Ball Cylinder Cast Iron Valves Stainless Steel Reed Head Aluminum Filter Canister Dimensions Weight 56 Lbs Shipping Weight 60 Lbs Size L X W X H 20 X 14 X 16 5 PROVI...

Page 7: ...6 COMPRESSOR DESCRIPTION 1 2 3 2 18 11 10 8 7 6 5 4 GR254CTS 12 5 14 13 9 17 15 16 4 ...

Page 8: ...ir Outlet Pressure Gauge Indicates air pressure to air hose 9 Regulator Control Knob Adjusts discharge air pressure setting 10 Pressure Switch Controls compressor motor start stop 11 On Off Control Turns compressor on or off 12 Motor Reset Switch Thermal overload protects motor 13 Drain Plug Allows crankcase oil to be drained 14 Dipstick Used to check oil level in crankcase 15 Compressor Pump Comp...

Page 9: ...kers must be rated accordingly 4 Use an extension cord with 3 prong grounding plug sized to prevent power loss and overheating of the motor Cord Length Wire Gauge Size up to 25 ft 12 ga Up to 100 ft 10 ga Up to 150 ft 8 ga Up to 250 ft 6 ga 5 Position compressor on a secure stable surface no more than 10 degrees off level 6 Open one tank drain cock and start compressor by pulling On Off button out...

Page 10: ...lockwise to decrease air pressure Outlet air pressure is indicated by gauge B Tank pressure is indicated by gauge A 6 Connect air hose to quick connect fitting D on regulator using a male quick connect fitting To connect air hose pull back outer ring on compressor fitting insert male hose fitting and release ring To release air hose push hose fitting in pull back outer ring on compressor fitting a...

Page 11: ...ion of compressor Make sure cover is in place and all components are in good condition Check compressor power cord and plug for damage Don t use compressor if cord or plug is damaged Contact your Grip Rite dealer for service Weekly Check Pressure Relief Valve for proper operation With tanks pressurized pull on Pressure Relief Valve ring Air must exhaust when ring is pulled Release ring air must st...

Page 12: ...11 COMPRESSOR SCHEMATIC PUMP ...

Page 13: ...et 1 GRFC44 12 Comp Piston Assy 1 GRFC67 Ring Set 1 GRFC56 Piston 1 GRFC33 Piston Pin 1 GRFC40 Snap Rings 2 GRFC21 Connecting Rod 1 GRFC45 13 Capacitor 1 GRFC2 14 Capacitor Cover 1 GRFC41 15 Dipstick 1 GRFC9 16 Screw 4 GRFC18 17 Crankcase Cover 1 GRFC22 18 Gasket 1 GRFC4 19 Oil Drain 1 GRFC19 20 Gasket 1 GRFC43 21 Motor Housing 1 GRFC42 22 Nut 2 GRFC13 23 16 AMP Manual Reset 1 GRFC1 24 Crankshaft ...

Page 14: ...TION QTY PART 29 Bearing 1 GRFC26 30 End Bell 1 GRFC30 31 Fan 1 GRFC29 32 Thru Bolt 2 GRFC31 33 Shroud 1 GRFC48 34 Washer 2 GRFC15 35 Screw 2 GRFC16 36 Gasket Set Includes parts GRFC4 GRFC34 GRFC35 GRFC43 GRFC44 1 GRFC57 COMPRESSOR SCHEMATIC TANK ...

Page 15: ...bber Foot 4 GRFC23 11 Check Valve 1 GRFC63 12 Nylon Tubing 1 GRFC27 13 Discharge Tube 1 GRFC55 14 Discharge Tee 1 GRFC54 15 Bleeder Valve 1 GRFC8 16 Nipple 1 GRFC5 17 Safety Valve 1 GRFC28 18 Cord w Plug 1 GRFC51 19 Pressure Switch 1 GRFC60 Pressure Switch Cover GRFC66 20 Tank Gauge 1 GRFC62 21 Nipple 1 GRFC5 22 Regulator 1 GRFC59 23 Screw TE 4 GRFC11 24 Line Gauge 1 GRFC61 25 Compression Nut 2 GR...

Page 16: ...ed Have authorized service dealer adjust pressure switch Safety relief valve pops open Pressure switch inoperable Have switch serviced by authorized service dealer Air leaks from safety relief valve Valve stuck or inoperable Pull on ring and release Replace valve if leak continues Tool sprayer or other accessory doesn t work properly Air pressure too low or too high Adjust regulator to provide pre...

Page 17: ...ittings Insufficient pressure at air tool or accessory Reed valve worn or damaged Have authorized service dealer replace Air intake filter dirty Clean or replace filter Compressor positioned on uneven surface Position compressor on level surface Oil leakage Have authorized service dealer repair unit Oil consumption excessive Worn cylinder or piston rings Have authorized service dealer repair unit ...

Page 18: ... wear damage or missing parts and have repairs made promptly Store unit in a dry cool place Storage in vehicles or trailers secure the compressor to keep it from tipping or being damaged by contact with other equipment Make sure gauges fittings and knobs are clear of objects that could cause damage Do not place heavy objects on top of compressor Check oil level Drain water from tanks Check clean a...

Page 19: ...LIABLE FOR ANY INDIRECT ACCIDENTAL OR CONSEQUENTAL DAMAGE FROM THE SALE OR USE OF THESE PRODUCTS THIS DISCLAIMER APPLIES BOTH DURING AFTER THE TERM OF WARRANTY THIS IS OUR WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING THE WARRANTIES OF MERCHANTABILTY AND FITNESS FOR A PARTICULAR PURPOSE EXCEPT AS MAY BE OTHERWISE PROVIDED BY LAW THIS LIMITED WARRANTY GIVES YOU ...

Page 20: ...19 PRIMESOURCE BUILDING PRODUCTS INC An Itochu Company ...

Page 21: ...UAL DE OPERACIÓN Y LISTA DE PIEZAS COMPRESOR MODELO GR254CTS Porque el trabajo de calidad requiere herramientas de calidad Distribuido por PRIMESOURCE BUILDING PRODUCTS INC Una compañía Itochu 800 676 7777 ...

Page 22: ...ósitos del compresor 13 Lista de piezas de los depósitos del compresor 14 Resolución de problemas 15 Procedimientos de mantenimiento 17 Almacenamiento 17 Garantía 18 ADVERTENCIA Este manual contiene instrucciones importantes de seguridad y operación que deben respetarse Se debe leer y entender este manual antes de operar este compresor De no seguir todas las instrucciones el operador y las persona...

Page 23: ...s de protección PELIGRO DE INHALACIÓN El aire comprimido puede contener monóxido de carbono u otros gases nocivos No use el compresor para proporcionar aire para la respiración PELIGRO DE ESTALLIDO El exceso de presión ocasionado por la manipulación indebida de los controles puede ocasionar lesiones graves o la muerte debido a una explosión PELIGRO DE DESCARGA ELÉCTRICA El contacto con los compone...

Page 24: ... pérdidas a tierra para usar el compresor al aire libre en garajes y en lugares húmedos USE UN CORDÓN DE ALARGAMIENTO DEL TAMAÑO APROPIADO El uso de un cordón de alimentación demasiado pequeño puede calentar excesivamente el cordón y causar cortocircuitos produciendo incendios y daños materiales Use un cordón de alargamiento homologado por UL para operar de forma segura con los requisitos del comp...

Page 25: ...ura recomendada para este compresor La alteración de estos ajustes puede producir una presión excesiva el riesgo de rotura de depósitos mangueras y equipos neumáticos y lesiones graves para el operador y las personas de los alrededores USE UNA MANGUERA DE AIRE CON UNA CAPACIDAD NOMINAL DE 150 LB PULG2 O SUPERIOR La manguera de aire debe tener una capacidad nominal para operar seguramente con la pr...

Page 26: ...ruptor de presión Interruptor de presión ENCENDIDO 95 lb pulg2 6 5 bares Interruptor de presión APAGADO 125 lb pulg2 8 6 bares Bomba del compresor Cilindros 1 Etapa de compresión 1 Lubricación Por salpicadura Tipo de aceite Aceite de compresor SAE 30W ISO 100 Cárter Aluminio Cojinetes De bolas Cilindro Hierro colado Válvulas Reed de acero inoxidable Cabeza Aluminio Filtro Cartucho Dimensiones Peso...

Page 27: ...6 DESCRIPCIÓN DEL COMPRESOR 1 2 3 2 18 11 10 8 7 6 5 4 GR254CTS 12 5 14 13 9 17 15 16 4 ...

Page 28: ...a de la manguera de aire 9 Perilla de control del regulador Cambia el ajuste de presión del aire de descarga 10 Control de encendido apagado Controla el arranque parada del motor del compres 11 Interruptor de reajuste del motor Enciende o apaga el compresor 12 Interruptor de presión La sobrecarga térmica protege el motor 13 Tapón de desagüe Permite vaciar el aceite del cárter 14 Varilla de medició...

Page 29: ...on un enchufe de conexión a tierra de 3 clavijas de tamaño apropiado para impedir la pérdida de corriente y el calentamiento excesivo del motor Longitud del cordón Longitud del cordón Longitud del cordón Longitud del cordón Hasta 25 pies Calibre 12 Hasta 100 pies Calibre 10 Hasta 150 pies Calibre 8 Hasta 250 pies Calibre 6 5 Coloque el compresor sobre una superficie segura y estable con un desnive...

Page 30: ... La presión del aire de salida viene indicada por el manómetro B La presión del depósito viene indicada por el manómetro A 7 Conecte la manguera de aire a la conexión rápida D del regulador usando una conexión macho rápida Para conectar la manguera de aire tire del anillo exterior en la conexión del compresor introduzca la conexión de manguera macho y suelte el anillo Para soltar la manguera de ai...

Page 31: ...úe una inspección visual del compresor Asegúrese de que la tapa esté colocada y que todos los componentes estén en buenas condiciones Compruebe el cordón de alimentación del compresor y el enchufe para ver si están dañados No use el compresor si el cordón o el enchufe está dañado Póngase en contacto con su distribuidor Grip Rite para cuestiones de servicio Semanalmente Compruebe la válvula de aliv...

Page 32: ...11 ESQUEMA DEL COMPRESOR BOMBA ...

Page 33: ...ura 1 GRFC44 12 Conjunto de pistón del compresor 1 GRFC67 Juego de anillos 1 GRFC56 Pistón 1 GRFC33 Pasador de biela 1 GRFC40 Anillos de resorte 2 GRFC21 Biela 1 GRFC45 13 Condensado 1 GRFC2 14 Tapa del condensador 1 GRFC41 15 Varilla de medición de nivel 1 GRFC9 16 Tornillo 4 GRFC18 17 Tapa del cárter 1 GRFC22 18 Empaquetadura 1 GRFC4 19 Desagüe de aceite 1 GRFC19 20 Empaquetadura 1 GRFC43 21 Caj...

Page 34: ...te 1 GRFC26 30 Cubierta de extremo 1 GRFC30 31 Ventilador 1 GRFC29 32 Perno pasante 2 GRFC31 33 Envuelta 1 GRFC48 34 Arandela 2 GRFC15 35 Tornillo 2 GRFC16 36 Juego de empaquetaduras incluye las piezas siguientes GRFC4 GRFC34 GRFC35 GRFC43 GRFC44 1 GRFC57 ESQUEMA DEL COMPRESOR DEPÓSITOS ...

Page 35: ...4 GRFC23 11 Válvula de retención 1 GRFC63 12 Tubo de nilón 1 GRFC27 13 Tubo de descarga 1 GRFC55 14 Te de descarga 1 GRFC54 15 Válvula de purga 1 GRFC8 16 Niple 1 GRFC5 17 Válvula de seguridad 1 GRFC28 18 Cordón con enchufe 1 GRFC51 19 Interruptor de presión 1 GRFC60 Tapa del interruptor de presión GRFC66 20 Manómetro del depósito 1 GRFC62 21 Niple 1 GRFC5 22 Regulador 1 GRFC59 23 Tornillo TE 4 GR...

Page 36: ... posición abierta Reemplace El compresor funciona continuamente no se apaga Conexión de aire en la manguera atascada en la posición abierta Repare o reemplace Interruptor de presión desajustado Haga que un distribuidor de servicio autorizado ajuste el interruptor de presión La válvula de alivio de seguridad se abre Interruptor de presión que no funciona Pida a un distribuidor de servicio autorizad...

Page 37: ...pare la unidad Fugas de aire Limpie o reemplace el filtro Manguera de aire demasiado pequeña o larga Compruebe si hay fugas en la unidad y corríjalas según sea necesario Válvula Reed desgastada o dañada Use una manguera de aire de diámetro grande y conexiones de capacidad más grande Presión insuficiente en la herramienta o en el accesorio neumático Filtro de entrada de aire sucio Pida que lo reemp...

Page 38: ...do o si faltan piezas y efectúe las reparaciones de forma inmediata Guarde la unidad en un lugar seco y fresco Almacenamiento en vehículos o remolques fije el compresor para impedir que se vuelque o se dañe por contacto con otros equipos Asegúrese de que los manómetros las conexiones y las perillas no tengan objetos que podrían ocasionar daños No ponga objetos pesados en la parte superior del comp...

Page 39: ...NERSTM FASTENERS UNLIMITEDTM PRIMESOURCE NO SERÁ RESPONSABLE DE NINGÚN DAÑO INDIRECTO ACCIDENTAL O EMERGENTE DE LA VENTA O EL US DE ESTOS PRODUCTOS ESTE DESCARGO SE APLICA TANTO A DURANTE COMO A DESPUÉS DE LA GARANTÍA ÉSTA ES NUESTRA GARANTÍA Y SUSTITUYE EXPRESAMENTE A LAS DEMÁS GARANTÍAS EXPLÍCITAS O IMPLÍCITAS INCLUIDAS LAS GARANTÍAS DE COMERCIABILIDAD E IDONEIDAD PARA UN CIERTO FIN EXCEPTO EN L...

Page 40: ...19 PRIMESOURCE BUILDING PRODUCTS INC Una compañía Itochu ...