Grind’n Brew
®
Coffee Systems Page 9
User Menu
The
User Menu
is accessed by pressing the
SET
key on the display board. Navigation is accomplished by pressing
the
UP
,
DOWN
and
SET
keys. Feedback to the user is shown by the 3-digit numerical display.
The
User Menu
exits after a 1 minute timeout or all modes are stepped through. This menu is disabled by the
User
Lockout Jumper
.
Brew Settings - Brew Cycle Selection
There are four independent settings for brew cycles: Regular Full Brew, Regular Half Brew, Decaf Full Brew and
Decaf Half Brew. The
User Menu
adjusts settings for the brew cycle selected by the keypad. For instance, if
you want to change settings for Decaf Half brew then set the keypad to the Decaf Hopper and Half Brew Size
before entering the
User Menu
. The keypad settings cannot be changed while the
User Menu
is displayed.
User Menu Navigation
Advancing through the menu is done by pressing the
SET
Key. Each parameter is adjusted by pressing the
UP
and
DOWN
keys. Pressing and holding the
UP
and
DOWN
keys will quickly scroll through settings. The table
below shows how to step through this menu.
Step Setting
Display
Adjustments
1
Temperature Scale
between
°F or °C
Displays the current
selection. Factory default
is “°F”
“°F” or “°C”
2
Water Temperature
setpoint in °F or °C
Displays the current
selection. Factory default is
“195” in °F or “91” in °C.
“170” to “205” °F
“77” to “96” °C
3
Show Auger Time
the amount of coffee beans fed
into the grinder
“At”
None
4
Set Auger Time
the amount of coffee beans fed
into the grinder
Displays the current
selection depending on Brew
Cycle
“0.1” to “45.0” seconds
5
Show Brew Time
Total amount of pour time for
the brew cycle
“br”
None
6
Set Brew Time
Total amount of pour time for
the brew cycle
Displays the current
selection depending on Brew
Cycle
“0.01” to “6.00” in minutes.sec-
onds
7
Show Pulse Brew
“P-b”
None
8
Pulse Brew Pulse Number
sets the number of pulses in
the brew cycle
Displays the current
selection depending on Brew
Cycle
“OFF” to “10”
9
Pulse Brew Pour Time
sets the amount of pour time in
each pulse
Displays the current
selection depending on Brew
Cycle
“0.05” to “1.00” in
minutes.seconds
10
Pulse Brew Delay Time
sets the amount of delay time
between each pulse
Displays the current
selection depending on Brew
Cycle
“0.05” to “1.00” in minutes.sec-
onds
11
Show Low Temp No Brew
“Ltn”
None
12
Set Low Temp No Brew
enable or disable
Displays the current
selection. Factory default
is “
YES
”
“OFF” or “ON”
Summary of Contents for 10H
Page 2: ......
Page 17: ...Grind n Brew Coffee Systems Page 17 Exploded View Grind n Brew Assembly ...
Page 20: ...Page 20 Grind n Brew Coffee Systems Exploded View Hot Water Tank Assembly Export Units ...
Page 21: ...Grind n Brew Coffee Systems Page 21 Single Bean Upper Assembly Dual Bean Upper Assembly ...
Page 22: ...Page 22 Grind n Brew Coffee Systems Wiring Diagram 115 230V 60Hz ...
Page 23: ......