Problem
Possible Cause
Remedy
Circuit breaker continuously
trips
• Insufficient current due to use of
extension cord
• Insufficient current due to
overloaded line
• Plug unit directly into outlet. Do not use
extension cord.
• Designate single line for unit. Do not
use multi outlet box.
Basket Out light flashing
(Display board displays “ER1”)
• Water fill valve on too long
• Water supply turned off
• Clean or replace water fill valve.
• Turn water supply on.
Basket Out light flashing
(Display board displays “ER2”)
• Problem with Thermistor
• Replace if defective.
Basket Out light flashing
(Display board displays “ER3”)
• Heater Relay failed
• Contactor Failed
• Heater Failed open
• Hi Temp failed
• Control Board output failed
• Replace defective component
Water not hot enough
• Thermistor not set high enough
• Adjust potentiometer
Water boiling (or steaming)
• Thermistor set too high
• Defective Thermistor
• Adjust potentiometer.
• Replace Thermistor.
Start switch not working
(Basket Out light illuminated)
• Brew basket out of place
• Replace basket.
No lights are on
(Including Warmer light)
• No power to brewer
• Power switch turned Off
• Turn power on.
• Turn switch on.
No touch pad lights
(other lights o.k.)
• Touch pad disconnected
• Reconnect touch pad.
Too much or not enough water
in decanter
• Water time adjustment
• Readjust.
Spray head dripping
• Lime build up in dump valve
• Delime unit.
Hot water spigot dripping
• Faulty seal
• Replace seal.
Hot water spigot not dispens-
ing
• Drain tube limed-up
• Defective valve seat
• Delime tank and drain tube.
• Replace seat.
Warmer Failure
• Loss of power
• Defective warmer switch or
warmer heater
• Check power source.
• Perform continuity test. Replace defec-
tive component.
Auger motor, water solenoid,
shutter not working
• Bus fuse on controller board is
blown
• Replace 5 Amp bus fuse.
Basket Out or Brew Cycle
indicators will not light up
• Polarity reversed
• LED burned out
• Connect black wire to + terminal of
LED.
• Replace LED.
Summary of Contents for 10H
Page 2: ......
Page 17: ...Grind n Brew Coffee Systems Page 17 Exploded View Grind n Brew Assembly ...
Page 20: ...Page 20 Grind n Brew Coffee Systems Exploded View Hot Water Tank Assembly Export Units ...
Page 21: ...Grind n Brew Coffee Systems Page 21 Single Bean Upper Assembly Dual Bean Upper Assembly ...
Page 22: ...Page 22 Grind n Brew Coffee Systems Wiring Diagram 115 230V 60Hz ...
Page 23: ......