15
USE AND CARE INSTRUCTIONS
Troubleshooting
WARNING
Turn gas off at source and turn Control Knobs to
OFF. Wait at least five minutes for gas to clear,
then retry.
If your grill still fails to light, check gas supply
and connections.
Repeat lighting procedure. If your grill still fails
to operate, turn the gas off at source, turn the
Control Knobs to OFF, then check the following:
If the grill fails to light :
1.
2.
3.
Misalignment of Burner Tubes over Orifices
Correction:
Reposition Burner Tubes over Orifices.
Obstruction in gas line
Correction:
Remove fuel line from grill. Do not
smoke! Open gas supply for one second to clear
any obstruction from fuel line. Close off gas supply
at source and reconnect fuel line to grill.
Plugged Orifice
Correction:
Remove Burners from grill by remov-
ing the rear of each burner using a Phillips Head
screwdriver. Carefully lift each Burner up and away
from gas valve Orifice. Remove the Orifice from
gas valve and gently clear any obstruction with a
fine wire. Then reinstall all Orifices, Burners,
Screws and cooking components.
If an obstruction is suspected in Gas Valves or
Manifold, call the Grill Information Center.
Obstruction in Burner Tubes
Correction:
Follow the Burner Tube cleaning
procedure on
page 17
of this Operator's Manual.
If the grill still does not light you may need to
purge air from the gas line or reset the
regulator excess gas flow device.
Note:
This
procedure should be done every time a new
LP Gas tank is connected to your grill.
To purge air from your gas line and/or reset
the regulator excess gas flow device:
Turn Control Knobs to the OFF position.
Turn off the gas at the tank valve.
Disconnect regulator from LP Gas tank.
Let unit stand 5 minutes to allow air to purge.
Reconnect regulator to the LP Gas tank.
Open the Grill Lids.
Turn tank valve on SLOWLY 1/4 of a turn.
Push and turn the middle Control Knob farthest
from open tank to HIGH.
Keep the control knob pushed in until the jet-fire
ignitor lights the burner.
Keep grill area clear and free from combustible
materials, gasoline and other flammable vapors
and liquids.
Do not obstruct the flow of air for combustion
and ventilation.
Keep the ventilation openings of the tank enclosure
cabinet free and clear of debris.
Visually check burner flames occasionally to
ensure proper flame pattern as shown below.
Failure to comply with these instructions may
result in a hazardous situation which, if not
avoided, may result in injury.
•
•
•
•
CAUTION
!
!
MAGNIFIED VIEW OF
BURNER FLAME
THROUGH LIGHTING
HOLE
WARNING
!
Should a FLASHBACK fire occur in or around
the Burner Tubes, follow the instructions below.
Failure to comply with these instructions could
result in a fire or explosion that could cause
serious bodily injury, death, or property damage.
!
Shut off gas supply to the gas grill.
Turn the Control Knobs to OFF position.
Open the Grill Lid.
Put out any flame with a Class B fire
extinguisher.
Once the grill has cooled down, clean
the Burner Tubes and Burners according
to the cleaning instructions in this
Operator's Manual.
GRILL INFORMATION CENTER
Call 8am to 5pm EST
1-800-667-7313
Monday through Friday
•
•
•
•
•