background image

12

USE  AND  CARE  INSTRUCTIONS

NOTE about LP Gas Tank Exchange Programs

Ÿ

How to Leak Test your LP Gas Tank
For your safety:

LP  Gas  Model  only:
Secure  two  20lb  LP  Gas  Tanks  to  Gas  Grill

Turn  your  LP  Gas  Tank  Valves  clockwise  to

the  closed  or  OFF  positon.
Hang  your  gas  tanks  on  the  top  Tank  Hooks.

The  ring  foot  of  the  gas  tanks  will  rest  on  the

Tank  Holder.

Type 1 connection  

per

ANSI Z21.58b-2012

Quick

Coupling Nut

Many retailers that sell grills offer you the option of

replacing your empty LP Gas tank through an exchange

service. Use only those reputable exchange companies

that inspect, precision fill, test and certify their tanks.

Exchange your tank only for an OPD safety feature-

equipped tank as described in the LP Gas tank section

of this manual.
Always keep new and exchanged LP Gas tanks in an

upright position during use, transit or storage.
Leak test new and exchange LP Gas tanks BEFORE

connecting one to your grill.

Ÿ

Ÿ

All leak tests must be repeated each time your LP Gas

tank is exchanged of refilled.
When checking for gas leaks do not smoke.
Do not use an open flame to check for gas leaks.
Your grill must be leak tested outdoors in a well-

ventilated area, away from ignition sources such as

gas fired or electrical appliances. During the leak test,

keep your grill away from open flames or sparks.
Do not use household cleaning agents. Damage to

gas assembly components can result.

Ÿ

Ÿ
Ÿ
Ÿ

Ÿ

If  growing  bubbles  appear  do  not  use  or  move

the  LP  Gas  tank.  Contact  an  LP  Gas  Supplier

or  your  fire  department!

  WARNING

!

!

Before  using  this  gas  appliance  read  all

instructions  and  perform  all  gas  leak-check

procedures  ev en  if  the  product  was

pre-assembled by the retailer or manufacturer.

  WARNING

!

!

Use a clean paintbrush and a 50/50 mild soap and

water solution.

Brush soapy solution onto LP Gas tank in the areas

indicated by the arrows. See diagram.

If growing bubbles appear do not use or move the

LP Gas tank. Call an LP Gas Supplier or your Fire

Department.

Place dust cap on cylinder valve outlet

whenever the cylinder is not in use. Only

install the type of dust cap on the cylinder

valve outlet that is provided with the cylinder

valve. Other types of caps or plugs may result

in leakage of propane.

Turn  all  Burner  Valves  to  the  OFF  position.
Inspect  the  valve  connection  port  and  regulator

assembly  for  damage  or  debris.  Remove  any

debris. Never use damaged or  plugged equipment.
Connect  the  regulator  assembly  to  the  tank

valve  and  HAND  TIGHTEN  nut  clockwise  to  a

full  stop.  DO  NOT  use  a  wrench  to  tighten

because  it  could  damage  the  Quick  Coupling

Nut  and  result  in  a  hazardous  condition.
Open  the  tank  valve  fully  (counterclockwise)  and

use  a  soapy  water  solution  to  check  all

connections  for  leaks  before  attempting  to  light

                                "Checking  for  LP  Gas  Leaks"

.

If  a  leak  is  found,  turn  the  tank  valve  off  and

do not use your grill  until  the  leak  is  repaired.

Cylinders Installation Code

The handling, storage, and transporation of all sizes of gas 

cylinders must be in accordance with 

ANSI/NFPA 58,

 

Storage and Handling of liquid Petroleum Gases,

 or the 

ETL

 

B149.1, Natural Gas and Propane Installation Code.

LP  Gas  Model  only:
Connect  Regulator  with  Hose  to  your  LPG  Tanks

your  grill.  See

CAUTION: 

When  the  appliance  is  not  in  use  the  gas

              must  be  turned  off  at  the  tanks.

Summary of Contents for BIG-8122C

Page 1: ...to the store 1 800 667 7313 8am 5pm EST Monday through Friday IMPORTANT FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any appliance Befo...

Page 2: ...CEIS DESIGNEDFOR OUTDOORUSE ONLY Combustion byproducts produced when using this product contain chemicals known to the State of California to cause cancer birth defects or other reproductive harm LPG...

Page 3: ...leaning methods 9 TO CLEAN BURNER TUBE INSERT HOOK HERE Burner Port Burner Foot Grill Information Center 1 800 667 7313 8am 5pm EST Monday through Friday Tools Required for Assembly include protective...

Page 4: ...4 x1 2 Phillips Head Screw QTY 28 Hardware Pack Diagram for Model BIG 8122C PART DESCRIPTION QTY PURPOSEOF PART Hardware Pack 1 For use in assembly 1 4 x3 8 Phillips Head Screw 4 Secures the Tank Hold...

Page 5: ...5 Parts Diagram for Model BIG 8122C 50 48 49a 49b 2 24 39 28A 27 28B 26 33 13 14 11 42 3 1 4 5 16 6 10 8 19 18 30 20 32 34 20A 31 43 23 25 21 20A 38 37 35 40 36 41 12 15 35A 35 35A 17 44...

Page 6: ...ft 2 18 Bowl Handle P05313009B 2 19 Protective Pad S0204 03 4 20 Latch As s em bly I S0174 13 4 21 H os e Bracket S0003 86 S43010 2 23 LPG Regulator with Hose S0167 78 2 24 Gas Valve Manifold As s em...

Page 7: ...t Follow the same on 4 sides Install Tank Holders and Casters 7 With an assistant lift Cart out of shipping carton and place it on the cardboard work surface 1 4 x1 2 Phillips Head Screw QTY 1 6 2 Ass...

Page 8: ...tion Code The installation shall be made with a connector installed on this grill with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA6 16 4 Install Lid Handles to Left and Righ...

Page 9: ...cle Attach the Grease Tray to the Bottom Bowl panel using the Wing bolts and tighten securely The Grease Tray is required to be present and centered for your safety Slide the Grease Receptacle over Gr...

Page 10: ...Grids Savor Plate WARNING Failure to read and follow the Use and Care Instructions could result in a fire or explosion that could cause serious bodily injury death or property damage Final Grill Asse...

Page 11: ...outlet pres sure of 11 water column W C for connection to an LP gas tank Only use the regulator and hose assembly supplied with your gas grill Replacement regulators and hose assemblies must be those...

Page 12: ...this gas appliance read all instructions and perform all gas leak check procedures even if the product was pre assembled by the retailer or manufacturer WARNING Use a clean paintbrush and a 50 50 mild...

Page 13: ...WARNING If you have a gas leak that cannot be repaired by tightening turn off the gas at the source disconnect fuel line from your grill and call 1 800 667 7313 or your gas supplier for repair assist...

Page 14: ...a faulty hose secure gas supply connections or to open the Lid before proceeding to the Lighting Procedures could result in a fire or explosion that could cause serious bodily injury death or propert...

Page 15: ...ank is connected to your grill To purge air from your gas line and or reset the regulator excess gas flow device Turn Control Knobs to the OFF position Turn off the gas at the tank valve Disconnect re...

Page 16: ...ng Clean Jet fire ignitor with a soft bristle brush Replace Flame Tamers and the Cooking Grids Reconnect the gas source and observe the Burner flame for correct operation 8 10 9 CAUTION Be sure your g...

Page 17: ...he Burner several times removing any debris Use an air hose to force air through each Burner Tube The forced air should pass debris or obstructions through the Burner and out the ports Cleaning The Bu...

Page 18: ...e you need to purge air from the gas line or reset the Regulator excess gas flow device as described above Question How and when do I clean the interior cooking components of my grill Cooking Grids Be...

Page 19: ...cooking preheat grill 3 to 5 minutes For low temperature cooking preheat grill 3 minutes To slow cook preheating is not necessary Indirect Cooking The indirect cooking method can also be used with th...

Page 20: ...ortation improper installation or operation purchaser servicing accident abuse fire alteration of the product in any way act of God natural disaster failure to read and or abide by any product warning...

Reviews: