21
BASIC SETTINGS
Within the Basic Setting, navigate through the menu screen until you find “MAIN MENU
IR1-BEHAVIOUR”.
1. Press the “P” button to enter this setting (figure 1).
2. Press the “+” or “-“ buttons to navigate through the options.
3. You can select the following options:
• IR1-CLOSE DIR
• IR1-OPEN DIR
• IR1-OPEN & CLOSE DIR
• IR1-CLOSE DIR + IMMEDIATE CLOSE
4. To confirm the setting, press the “P” button to save and return to the
main menu screen.
NOTE: The above process is the same for IR2 & IR3 Behaviour.
S
P
+
-
MAIN MENU
IR1-BEHAVIOUR
NOTE: If Timer To Close (TTC) is activated,
during the pause time, when released after 2
seconds it will close immediately.
figure 1
REMOTE CONTROL BEHAVIOUR
22
Within the Advance Setting, navigate through the menu screen until you find “MAIN MENU
REMOTE CONTROL BEHAVIOUR”.
1. Press the “P” button to enter this setting.
2. Press the “+” or “-“ buttons to navigate through the options.
3. You can select the following options:
• OPEN-CLOSE-OPEN
• OPEN-STOP-CLOSE-STOP
• OPEN-STOP-CLOSE-OPEN
• OPEN ONLY
4. To confirm the setting, press the “P” button to save and return to the main menu
screen.
S
P
+
-
MAIN MENU
REMOTE CONTROL
BEHAVIOUR
figure 1
LIMIT AND FORCE LEARNING
21
Within the Basic Setting, navigate through the menu screen
until you find “MAIN MENU LIMIT & FORCE LEARN”.
1. Press the “P” button to enter this setting (figure1).
2. The menu screen will begin flashing “LIMIT & FORCE
LEARN” while this sequence is in progress and
the
gate will start to move.
3. Three seconds after successfully completing the
“LIMIT & FORCE LEARN” setup, the display will return
to the main menu in standby mode.
Note: If the LIMIT & FORCE LEARN setup needs to be
stopped, press “S” button. The screen will display
“LIMIT & FORCE LEARN INTERRUPTED” (figure 2).
After 5 seconds, the screen will display “LIMIT & FORCE
LEARN”.
S
P
+
-
MAIN MENU
LIMIT & FORCE LEARN
S
P
+
-
LIMIT & FORCE LEARN
INTERRUPTED
S
P
+
-
LIMIT & FORCE LEARN
S
P
+
-
MAIN MENU
SELECT
APPLCATION
S
P
+
-
MAIN MENU
LIMITED & FORCE
LEARN
S
P
+
-
MAIN MENU
LIMITED & FORCE
LEARN
S
P
+
-
CYCLES 000,000
STANDBY
GATE CLOSED
figure 1
figure 2
figure 3
IR BEHAVIOUR