19
START UP PROCEDURE
The Green LED on the charge controller should flash, and the panel voltage should be around
60-70V in full sunlight. As this charge controller auto-detects voltage, on its first start up it can
sometimes default to 12V, and will give a battery over voltage warning.
To fix this, switch off all circuit breakers in the reverse order of step 15. Then switch them back on.
Switch on the circuit breakers in the following order. First switch on the battery to charge controller
breaker C63. Then the battery to inverter C125. Finally, the panels to the charge controller C32.