SPECIFICATIONS
Velocity Ranges ..........................
Base & Metric Models:
0-2m, 10 & 20m/s, field selectable
Imperial Model:
0-400, 2000 & 4000 fpm, field selectable
Velocity Accuracy ......................
Metric:
Range - 0...2 m/s: <0.2 m/s + 5% from reading
Range - 0...10 m/s: <0.5 m/s + 5% from reading
Range - 0...20 m/s: <1.0 m/s + 5% from reading
Imperial:
Range - 0...400 fpm: <20 fpm + 5% from reading
Range - 0...2000 fpm: <100 fpm + 5% from reading
Range - 0...4000 fpm: <200 fpm + 5% from reading
Thermal Shift ...............................±0.8 %FS / °C
Calibration ...................................Units calibrated at 22°C (71.6°F) Rapid thermal shift stabilization time 10 min.
Temperature Range ..................0 to 50°C (32 to 122°F)
Temperature Accuracy ............<0.5°C for velocity >0.5 m/s (<0.9°F for V > 100 fpm)
Operating Conditions ..............0 to 50°C (32 to 122°F), 0 to 95 %RH, non-condensing
Storage Temperature ...............-20 to 70°C (-2 to 158°F)
Media Compatibility .................Dry air or non-aggressive gases
Output Signal 1 (Tout) .............0-10 V (linear to temperature) L min 1K Ω
4-20 mA (linear to temperature) L max 200 Ω
Output Signal 2 (Vout) .............0-10 V (linear to m/s) L min 1K Ω
4-20 mA (linear to m/s) L max 400 Ω
Optional Relay Out....................Potential free SPDT (NC, COM, NO)
250 Vac, 6A / 30 Vdc, 6A adjustable switching point and hysteresis
Power Supply ..............................24 Vdc / 24 Vac ±10%
Current Consumption ..............
Current:
75 mA (90 mA with relay)
Voltage:
35 mA (90 mA with relay)
Optional Display ........................4 digit LCD backlit display
Size:
45.7mm W x 12.7mm H (3.5" x 0.5")
Display Units ...............................
Metric:
m/s and °C
Imperial:
fpm and °F
Enclosure ......................................
Case:
ABS
Cover:
Polycarbonate
Ratings:
IP54 (NEMA 3)
Probe:
304 series stainless steel
Mounting Flange:
LLPDP
Dimensions ..................................
Case:
90mm W x 71.5mm H x 36mm D (3.5” x 2.8” x 1.4”)
Probe:
OD 10mm (0.394”), length 210mm (8.26”) from bottom of cover
Mounting......................................Mounting flange, Ø4mm (11/64")
Insertion Lenth with Flange ..Adjustable 50-180mm (2"-7.08")
Electrical Connections .............Power Supply & Signal Out: 4-screw terminal block 12-24 AWG (0.2-1.5mm
2
)
Relay Out: 3-screw terminal block 12-24 AWG (0.2-1.5 mm
2
)
Cable Entry ..................................M16 (0.625") cable gland
Weight ...........................................220g (7.76oz)
Approvals .....................................CE, RoHS
Country of Origin .......................Finland