PTFM 1.0 Portable Transit Time Flow Meter
TRANSDUCER MOUNTING
Prepare an area 2" wide by 4" long (50mm x 100mm) for transducer bonding by removing loose paint,
scale and rust. The objective of site preparation is to eliminate any discontinuity between the transducer
and the pipe wall, which would prevent acoustical coupling.
A TMK1 Transducer Mounting Kit is supplied with each Greyline flow meter. It includes recommended
coupling compound in a plastic applicator and a stainless steel mounting bracket with adjustable pipe
straps. Use the Alignment Bar (included) to align transducer brackets for V and W mode mounting.
END VIEW
ADJUSTABLE
STAINLESS STEEL
PIPE CLAMP
PIPE
TRANSDUCER
TRANSDUCER
MOUNTING
BRACKET
Mount the PC16 Mounting Bracket as illustrated on pipes
0.6" / 15 mm OD or larger. Stainless
steel bands are included for mounting on pipes up to 30" / 750 mm OD.
Additional stainless steel bands (by customer) may be combined to mount on larger pipes.
PIPE
PIPE
TRANSDUCER
MOUNTING
BRACKET
ALIGNMENT BAR